TRICONEX 3351
- T/T
- 1 days
You May Like
Product Details
Brand Name | TRICONEX | Place of Origin | China | |
Model Number | TRICONEX 3351 |
Product Description
Brand:TRICONEX
Type:3351
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
MPU GEAR RATIO dflt= 1.0 (0.05, 100) Enter the speed sensor gear ratio followed by the ENTER key. This value is the ratio of the speed sensor gear to the turbine shaft. This gear ratio is the result of dividing the speed of the speed sensor gear by the speed of the turbine shaft. FAILED SPEED LEVEL (RPM) dflt= 250 (0.5, 1000) Enter the Failed Speed Level (in rpm) followed by the ENTER key to set the speed probe input failure level. If speed drops below this level, the control will determine the speed input device is failed and issue an alarm. If all speed inputs fail, the 505E will issue a trip on loss of speed inputs. (Must be greater than or equal to 0.0204 x Overspeed Test Limit setting) USE SPEED INPUT #2? dflt= NO (Yes/No) Select YES followed by ENTER if both speed inputs are to be used. FAILED SPEED LEVEL (RPM) dflt= 250 (0.5, 1000) Enter the failed speed level (in rpm) followed by the ENTER key to set the speed probe input failure level. If speed drops below this level, the control will determine the speed input device is failed and issue an alarm. If all speed inputs fail, the 505E will issue a trip on loss of speed inputs. (Must be greater than or equal to 0.0204 x Overspeed Test Limit setting) OFF-LINE PROPORTIONAL GAIN dflt= 5.0 (0.0, 100) Enter the off-line PID proportional gain, in repeats-per-second (rps) followed by ENTER. This value is used to set speed/load control response when the Generator or Utility Tie breaker contacts are open (if the unit is a generator) or if the turbine speed is below minimum governor speed (if the unit is not a generator) or when the Select Dynamics function is used and the contact is open. This value can be changed in the Run Mode while the turbine is operating. A recommended starting value is 5 rps. OFF-LINE INTEGRAL GAIN dflt= 0.5 (0.01, 50) Enter the off-line PID integral gain percentage followed by ENTER. This value is used to set speed/load control response when the Generator or Utility Tie breaker contacts are open (if the unit is a generator) or if the turbine speed is below minimum governor speed (if the unit is not a generator) or when the Select Dynamics function is used and the contact is open. This value can be changed in the Run Mode while the turbine is operating. A recommended starting value is 0.5%. OFF-LINE DERIVATIVE RATIO dflt= 5.0 (0.01, 100) Enter the off-line PID derivative ratio followed by ENTER. This value is used to set speed/load control response when the Generator or Utility Tie breaker contacts are open (if the unit is a generator) or if the turbine speed is below minimum governor speed (if the unit is not a generator) or when the Select Dynamics function is used and the contact is open. This value can be changed in the Service Mode while the turbine is operating. A recommended starting value is 5% (see Chapter 5—PID Dynamics Settings for more information).
ON-LINE PROPORTIONAL GAIN dflt= 5.0 (0.0, 100) Enter the on-line PID proportional gain percentage followed by ENTER. This value is used to set speed/load control response when the Generator and Utility Tie breaker contacts are closed (if the unit is a generator) or if the turbine speed is above minimum governor speed (if the unit is not a generator) or when the Select Dynamics function is used and the contact is closed. This value can be changed in the Run Mode while the turbine is operating. A recommended starting value is 5%.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Product Categories
New Products
-
HONEYWELL 51305896-200 NIM MODEM
-
HONEYWELL 51306673-100 EPNI
-
HONEYWELL 51401583-100 EPNI
-
HONEYWELL 51402455-100 MP-DNCF02-200
-
HONEYWELL 51402455-100 MP-DNCF02-201
-
HONEYWELL 51403519-160 K4LCN-16
-
HONEYWELL 51403645-100 SBHM
-
LAM 810-800082-043
-
S21260-SRS
-
IS200SRTDH2ACB
-
IS220PAICH2A 336A4940CSP11
-
IS220PDIAH1A 336A4940CSP1
Popular Searches
- food processor
- log splitter
- network switch
- network hardware
- cisco module
- industrial computer
- poe splitter
- poe
- poe injector
- cisco
- motherboard
- network equipment
- firewall
- video wall processor
- Audio Processor
- cisco network module
- interface processor
- plug-in module
- route
- led module
- Led Lighting
- laser machine
- fiber optic
- ftth
- diode
- laser equipment
- Laser Diode
- laser module
- media converter
- sfp transceiver
Recommended Products
- Bently Nevada 330130-085-00-CN
- Bently Nevada 21000-34-05-15-056-04-02
- Bently Nevada 330910-01-07-10-01-00
- Bently Nevada 330851-02-000-050-50-00-05
- Bently Nevada 330103-00-17-10-02-CN
- Bently Nevada 330103-01-06-05-02-05
- Bently Nevada 330103-00-04-10-12-00
- Bently Nevada 330103-00-21-05-11-05
- Bently Nevada 330101-00-25-05-02-05
- Bently Nevada 330903-00-04-05-02-00
- Bently Nevada 330101-00-24-05-02-00
- Bently Nevada 330104-00-12-10-02-05
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile