Home > Products > Industrial Measuring & testing Instruments > Coating Thickness Measuring Tools for Corrosion Protection Films on Metal
Coating Thickness Measuring Tools for Corrosion Protection Films on Metal
- Ningbo/Shanghai
- T/T Credit Card
You May Like
-
1500um Widely Digital Non-destructive Coating Thickness Measuring Tool
-
Precise Coating Thickness Measurement Tools of 1500um
-
Professional Coating Thickness Measuring Meter
-
Professional Coating Thickness Measuring Meter With General Group Which Could Store the Readings in Memory and Not Lost
-
Professional and High Detection Accuracy Coating Thickness Measuring Gauge
-
Professional and Widely Used Coating Thickness Measuring Tools of 1500um
Product Details
| Place of Origin | China | Brand Name | PULANI | |
| Model Number | 2013PLN-YT | Power | Electronic | |
| Usage | Other, Measure coating thickness on metal substrate |
Product Description
1 Product Introduction
The coating thickness measuring instrument uses a dual function measurement method, it can automatically identify magnetic and non-magnetic substrate, and then use the appropriate test method, it can measure the thickness of the non-magnetic coating (such as aluminum, copper, enamel, rubber, paint, etc) on magnetic metal substrates (such as steel, iron , alloy and Hard magnetic steel).And the non-conductive coating thickness on a non-magnetic metal substrate.
The instrument has advantages of high detection accuracy, reliable and easy to maintain, good stability, simple operation, etc. It can be widely used in manufacturing, metal processing industry, chemical industry, commodity inspection and testing fields.
Features Introduction:
l More widely measuring range : 0-1700um
l Automatic identification substrate material and display it on the LCD
l Big screen, and a variety of colors back-light optional
l Button is simple, easy to operate ,one-hand operation
l Convenient automatic calibration function
l Automatic correction function to prevent misuse calibration
l Dynamically adapt to environmental features
l V shaped groove suitable for measurements on cylindrical parts
l Special probe structure has better stability
l Beep when measurement or calibration is completed
l 180 degree flip for easy read data with top surface
Vision | Feature |
PLN-CT2013FN updated | Automatic temperature calibration version |
According to the function it can be divided into the following version:
2 Product Appearance
The top is the LCD, the middle are three buttons, "+" "Menu" "-" ,on the bottom is the sensor.
3 Technical Parameters
Measurement range: 0~1700μm, 0~67.8 mils
Accuracy: ± (2μm +3%H), H-standard coating thickness
Storage temperature: 10℃~60℃
Temperature: 0℃~40℃
Probe: built-in probe
Power supply: 2 x 1.5V(AAA alkaline)
Body size: 96*50*25mm
Weight: 41g
4 Switching The Instrument ON/OFF
When the device is powered up, it needs to be detected itself automatically, so the open method is: using hand to press down the test probe and quickly leave,then the device shows “222” and a buzzer sound,when the device shows “---” complete automatic detection.
Note:
The probe do not close to the metal object when starting.
The buzzer will continue to alarm if the probe keep down after the device start.
The device will be shut down if does not operate within 30s.
5 Handling Instruction
5.1 Switch the display unit
In standby mode, press "+" key to switch between units of um and mil. After switching units, all of the interface will display in the unit except multi-point calibration state.
5.2 Switching display mode
After the standby mode or the measurement, the short press "-" key can be switched between the display and the back display.
5.3 Measurement methods
Place The instrument sensor contacts to the material for tested and pressed, wait 1 to 2 seconds after buzzer short beep sound, the measured data will be displayed on the LCD screen.
If the substrate material is different, the calibration should be carried out first and then measured.
Calibration method reference "standard piece calibration" section.
5.4 Historical Data
In standby mode Press "MENU" button once, you can enter to view the status of the historical data, instrument store up to 20 groups of historical data.
5.4.1 View historical data
After pressing the MENU screen displays "NO 0.", By a short press "+", "-", you can turn on the next turn data, save up to 20 data. "NO. X" indicates the most recent X time measurement data, the X greater the data older.
5.4.2 Delete the historical data
Delete current data: In View mode, press "+", "-", select the data you want to delete, long press the "+" button.
Delete all: In View mode, long press the "-" button, can delete all the data. After you remove all 20 sets of historical data show non-ferromagnetic 0.0um.
5.4.3 View statistics
Enter the measuring status, continuous short press "MENU" key, can view the historical data in turn of maximum ,minimum value, average value ,then exit of the statistical value status(After boot, if the measurement of data, it is the last time of the measurement, otherwise it is no measurement value of white screen). If you want to directly measure , only need to put the instruments on the surface which you want to measuring ,it will automatically enter measurement status.
Note: the average value, the minimum value of the data is not measured in 0 of the data statistics.
5.5 Switch back-light
In view statistics :Enter the maximum mode (see 4.3.3) (bottom of the screen display MAX), press "+", you can open / close the back-light.

6 Restore Factory Setting
Restore factory settings also called initialization.
In standby mode, continues press "-" key , the instrument will go to restore the factory operation. When the screen shows "000,Fe,NFe,cal" and buzzer ,keep press the key of “-”till for a while and all the character has been displayed on the screen,it means that the restore factory settings operate has been finished. At the same time ,the historical data and the calibration value also has been cleared.
Note 1:In the whole process, we need keep press the key "-" , if you don’t keep press the key of "-" all the time during the whole process , please to redo the whole process. And this step of the instructions must be in strict carry out, otherwise unknown error maybe occurs.
Note 2:Please ensure the instrument probe is not touched with any object (the probe dangling).
7 Calibration
The device with 2 kinds of calibration mode,the two calibration models are very convenient, for different customers according to their own application to choose :
A:The standard calibration mode is provided with 0, 50, 100, 250, 500um calibration shim, it is more easy for new user, only need to choose the corresponding calibration mode and the right calibration shim ,then to do the calibration,it is very easy and more convenient.
B:The Multi-point calibration which could according to customer different application of special thickness to do the calibration operate . For example, client has standard thickness of 80um, which different with our standard shims ,then need calibration with multi-calibration mode.
7.1 Standard Calibration
Basic instruction : In the standby mode or measuring mode, long press "MENU" key to enter the film standard calibration status, when the display will show "CAL" logo,(the first screen will show of “0.0 cal ” zero film calibration status), then there have 5 different calibration status ,press "+" or "-" , the five kinds of film calibration status will be display in turn , detail information as below :
0.0 : zero automatic calibration
50 : 50um film automatic calibration
100: 100 um film automatic calibration
250 : 250um film automatic calibration
500: 500um film automatic calibration
Calibration operate : Firstly ,long press “menu” to enter to the film calibration interface, then select the corresponding calibration mode of 0.0/50/100/250/500 ,via short press key “+”/ “-” ,then put the device on the corresponding film, vertically press the device probe on the film ,and the best do 2 or 3 times again, every time of the calibration interval should be keep for several seconds and let the probe a little far from the metal to keep the accuracy. The calibration operation can be repeated until you believe it is meet your desire.
Exit the calibration : when calibration has complete, short press "MENU" to exit the calibration status ,then it will show us to the measuring status.
Note:
It is important that measuring the standard film thickness with corresponding film calibration status . So when you find that you run this instrument calibration status with a mistake and some errors information shows on the display, we recommend to do the restore of factory operate . Such as calibration 50um put the film as 100um, the machine will display E01, buzzer continuous ring alarm, when the sensor been lift and buzzer will stop ringing.
7.2 Multi-point calibration
When you have a standard shim which different with us, firstly measure the shim on the Fe or NFe substrate, then get the in initial value , then lift the instrument , and long press "+" into the multi-point calibration interface, the screen shows "CAL". At this point, the short press "+" or "-" can adjust the measurement value, and the long press "+" or "-" to speed up the adjustment of 10 times. When adjusted to the standard value of the calibration shims, the calibration is finished, then the short press "MENU" key to exit. You can according to your detail desire to repeat this operate to get more accuracy data.
7.3 Clear calibration data
First enter the Statistics status and enter to “Min” status (see 4.3.3) , continues press "-" key , the instrument will go to independent restore the factory operation. When the screen shows "000,fe,nfe,cal" and buzzer ,then keep press the key "-" for a while till all the character displayed on the screen, it means that the restore factory settings operate has been finished..
8 Attention
- 1. Before the measurement, calibration is very important to keep the gauge in high accuracy status, zero calibration should be carried out when you firstly use the gauge .
- 2. If you have the zero substrate of your product, the best do the zero calibration of your own substrate then to measuring the coating thickness .
- 3. If you calibration with wrong operate , the best way is restore factory with long press”-”.
- 4. When the screen appears battery flag alarm, suggest to replace the battery, otherwise the impact of measurement error, if the instrument will not work for a long time, it is suggested to remove the battery.
- 5. If the instrument has some unusual error, take out the battery, and keep for several minutes, then to restore the gauge, it will be recover.
- 6. If the shim is too thin (less than 0.5mm), too small (less than 25X25mm), not recommended for measurement, otherwise the data which will not be accuracy.
- 7. When do the calibrate and measuring operate, please keep the probe vertically to the metal surface and during the interval ,the best keep the probe far from the metal surface at least over 10 cm to keep the accuracy of the device.
- 8. On the edge of the measuring surface or measuring the curvature of the mask, it will affect the accuracy of the measurement.
9 Cue Information
NO | Symbol | Meaning | Operate | Remarks |
1 | - - - | Standby state | Measurement /view |
|
2 | FFF | The measured value is greater than 1700 um or base material is not FE or NFE |
|
|
3 | AVG | Mean value |
|
|
4 | MAX | Maximum value |
|
|
5 | MIN | Minimum value |
|
|
6 | FE | Ferrous |
|
|
7 | NFE | Non- Ferrous |
|
|
8 | um | Micron (Metric length unit) | Short press K1 can switch |
|
9 | Mil | Military (British length unit) | Short press K1 can switch |
|
10 | CAL | Calibration state | Calibrate operate |
|
11 |
| Low battery voltage | Change battery |
|
12 | E01 | Misplaced calibration shim | Play the suit shim |
|
13 | 222 | On starting | Self-test processing |
|
14 | NO | Number symbol | Short press the “+”/ “-” |
|
10 Key Description
NO | Key | Short press in Key description | Long press in Key description | Short press in Calibrate | Long press in Calibrate |
1 | +(Left) | Switch Unit | Multi- point calibration | Increase(Next) | Increase(Next) |
2 | MENU (Middle) | Check History Record | standard calibration | Enter(Exit) | Exit |
3 | -(Right) | Switch Show Direction | Initialization | Decrease(Last) | Decrease(Last) |
Note:The standard calibration is also called single point calibration, some versions do not have this feature.
11 Common Problem
NO | Problem | Solution |
1 | Larger measurement Deviation | The deviation maybe caused by the calibration error , or abnormal phenomenon shows FFF, please return to the factory after the re calibration |
2 | Battery alarm | When the screen appears battery logo alarm, please replace the battery, otherwise the measurement accuracy will be affected. If you want to save electricity, can turn off the back-light. And remove it ,when you long time no use the device. |
3 | Users have their own base material | If the user has its own base material, the best to calibrate with zero calibration firstly then according to the detail desire to do the other thickness calibration operate . |
4 | Boot alarm | The buzzer continue alarm, due to the probe need get away from the material object after power on. |
5 pcs gauges you received are with sample package. Now there are 2 types of regular package:
(1) 1 complete set of gauge package: 1 pcs gauge, 1 set calibration, 1 instruction, 1 black glasses box.
(2) 5 complete sets of gauge package: 5 pcs gauge, 5 sets calibration, 5 instructions, 5 black glasses boxes, 1 white carton box whose outside is with the color cover.


1) How the coating thickness gauge shut down?
A: Our coating thickness gauge adopt with automatic shutdown, when you stop using it, it will be shutdown automatic after 30 seconds.
2) What angle should be kept with Coating thickness with the analyte ?
A: The probe must be kept perpendicular to the surface with the measured material, otherwise it will lead to considerable error.
3) How to maintain accuracy of measurement when we need repeatedly measurements ?
A: When we need repeatedly measure, the thickness gauge should be keep the distance more than 3cm away from the analyte and at least keep 2 seconds or more interval .(Attention :Do not drag along the surface to the side of the probe to avoid probe magnetization.it will be impact of next measurement result)
4) When should we to calibrate the Coating thickness ?
A: Our thickness gauge has been calibrated , in most time, we just need to check whether the uncoated substrate is normalized to zero .Usually when the measurement accuracy beyond the precision values ,it need to be calibrated (refer to the instructions precision value range) . Calibration method according to operating instructions.
5) When the Coating thickness display with"" ,What does it mean?
A: It indicates that the battery voltage is low, please replace the battery in the automatic shutdown, otherwise it will affect the measurement accuracy.
6) How to choose the zero substrate?
A: The thickness of zero substrate should be used as the test material to avoid the permeability of different materials and measurement errors.
7) How to choose the zero substrate surface?
A: Use the gauge should be in the same part of the material being tested after calibrating to zero, and then measuring the same part. If the measuring pipe, bar and other curve surface materials, but the user indeed calibrating to zero with substrate of flats surface , this will affect the accuracy of the measurement. And choose the calibrating zero surface should be more smooth.
8) Coating thickness gauge has been calibrated, why also the measurement also not accurately?
A: The coating thickness calibration could not choose the substrate random ,firstly calibrating to zero based on the same test material of substrate which without coating , then put the calibration sheet in the top to calibrate, so that could get reliable measurement data. Remember: Be sure to use the same shape, the same material, the same roughness zeroing calibration substrate.
9) Why the different coating thickness measured data is not the same?
A: Due to different coating thickness gauge calibrated with different substrate before use . For consistency, we should make them in the same uncoated substrate to do the zero calibration, and then put the calibration sheet in the top to calibrate, so different coating thickness measurement data will be keep consistent.
10) When should we to replace to Standard film ?
A: The coating thickness calibration depends on the calibration sheet, so it is very important that keep the calibration sheet in good condition. If the calibration sheet has been used for many years and not in a good condition, please replace it . Otherwise, the measurement data will be inaccurate.
Contact Us
- Hangzhou Pulani Electronic Technology Co., Ltd.
- Contact nameDemi Guo Chat Now
- Phone86-571-85829611
- AddressBlock D,Floor 14th ,Chunxiao Court,Zhongshan Garden, No. 221, Zhaohui Road, Hangzhou, Zhejiang
Product Categories
| Automobile & Motocycle Electronic Products | Industrial Measuring & testing Instruments | New Products |
New Products
-
Made in China Widley Used and Professional Paint Check Meter
-
More Professional Coating Thickness Measuring Tools With Continous Measure Mode to Continously Measuring in a Certain Cycle
-
More Professional Coating Thickness Measuring Tools Meter With Both of fe and Nfe Probe
-
Coating Thickness Measuring Tools for Metal Coating
-
Popular Newest Type of Paint Coating Thickness Gauge Meter Tester Which Built in F &NF Probe
-
Paint Coating Thickness Gauge Meter Tester Which Built in Automatic Identification of F &NF Probe
-
Easy Operate Widely Used for Automobile Fields Coating Thickness Meauring Tools
-
Easy Operate Coating Thickness Measuring Tools Meter for the Chemical, Automobile, Ship Building
-
2.2 % Um/mil High Accurary Coating Thickness Measuring Tools Meter
-
Fast Automatically Detect the Substrates Type and Coating Thickness Measuring Tools
-
New Type Paint Thickness Gauge for Paint Shops and Electroplaters
-
Paint Coating Thickness Metere of Both Principles Magnetic Induction and the Eddy Currents
-
Hand Held Ultrasonic Steel Thickness Measuring Gauge Meter
-
Made in China Steel Ultrasonic Thickness Measuring Gauge Tester Meters
-
High Accuracy Non-destructive Coating Thickness Checking Tool Gauges
-
China Made Popular Coating Thickness Checking Tool
-
1500um Digital Non-destructive Coating Thickness Measuring Gauge
-
Digital Car Paint Coating Thickness Gauge Meter Tester 1500um
-
Digital Car Paint Coating Thickness Measuring Meter Tester Gauges
-
Internal FN Probe Car Paint Coating Thickness Measuring Meter Tester Gauges
-
Built in Dual Use Probe Car Paint Coating Thickness Gauge Meter Tester Quality Choice Supplier's Choice
-
Built in F & NF Internal Probe in One Gauge of Measuring Coating Thickness
-
Large LCD Screen Zinc Coating Thickness Measuring Gauge
-
Large LCD Screen Measuring Paint Coating Thickness Tester Gauges for Cars
Popular Searches
- digital tester
- resistance tester
- electrical instrument
- test instrument
- lab equipment
- analysis instrument
- laboratory instrument
- asphalt mixture mixer
- launch x431 master
- x431
- gloss meter
- resistance meter
- digital instrument
- dc load bank
- testing equipment
- testing machine
- battery load bank
- circuit tester
- impact tester
- lab instrument
- weather station
- gps receiver
- test equipment
- laboratory equipment
- electronic timer
- electronic meter
- electronic instrument
- electricity meter
- data collector
- experiment apparatu
Recommended Products
- Dental Material Testing Machine,Adhesive Bond Tester
- Professional Computer Controlled Material Lab Universal Testing Machine 50kn Computer Controlled Electronic Fabric Tensile Strength Tester
- Servo Motor Control Compression Universal Testing Machine 30kn
- Computerized Electronic Universal Ceramic Materials 3 Point Bending Testing Laboratory Equipment 30kn
- Computer Controlled Electronic Fabric Tensile Strength Tester
- 30kn Computerized Servo Motor Control Universal Tensile Testing Machine
- Servo Motor Control Material Lab Testing Machine With Extensometer
- Computerized Universal Testing Machine With Extensometer 20kn
- Computer Controlled Electronic Universal Tensile Testing Machine 20kn
- Computerized Electronic Table Type Universal Testing Machine Tensile and Compression Test
- Computerized Servo Motor Control Universal Tensile Testing Machine
- Computer Controlled Electronic Universal Tensile Testing Machine With Aluminum Foil Copper
Find Similar Products By Category
- Instruments & Meters > Test Instrument > Test Machine
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Demi Guo
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile






1500um Widely Digital Non-destructive Coating Thickness Measuring Tool
Precise Coating Thickness Measurement Tools of 1500um
Professional Coating Thickness Measuring Meter
Professional Coating Thickness Measuring Meter With General Group Which Could Store the Readings in Memory and Not Lost






More Professional Coating Thickness Measuring Tools Meter With Both of fe and Nfe Probe
Coating Thickness Measuring Tools for Metal Coating
Paint Coating Thickness Gauge Meter Tester Which Built in Automatic Identification of F &NF Probe
Easy Operate Widely Used for Automobile Fields Coating Thickness Meauring Tools
Easy Operate Coating Thickness Measuring Tools Meter for the Chemical, Automobile, Ship Building
2.2 % Um/mil High Accurary Coating Thickness Measuring Tools Meter
Hand Held Ultrasonic Steel Thickness Measuring Gauge Meter
Made in China Steel Ultrasonic Thickness Measuring Gauge Tester Meters
High Accuracy Non-destructive Coating Thickness Checking Tool Gauges
Internal FN Probe Car Paint Coating Thickness Measuring Meter Tester Gauges
Built in Dual Use Probe Car Paint Coating Thickness Gauge Meter Tester Quality Choice Supplier's Choice
Built in F & NF Internal Probe in One Gauge of Measuring Coating Thickness
Large LCD Screen Zinc Coating Thickness Measuring Gauge