Home > Products > Smoke detector > Anka tracking IP 24v addressable photoelectric smoke alarm AJ-6930
Anka tracking IP 24v addressable photoelectric smoke alarm AJ-6930
- 100000 Unit / Units per Month
- shenzhen
- T/T Credit Card
You May Like
-
fire alarm 2 wire combined co and smoke detector AJ-751
-
fire alarm sound & flash ceiling mounted smoke carbon Monoxide detector AJ-751
-
large building fire alarm addressable smoke alarm AJ-6930
-
factory price top mounted combo co and smoke detector
-
household standalone ionisation smoke alarm AJ-709
-
CE approved battery powered ionizing smoke alarms AJ-709
Product Details
Place of Origin | Guangdong, China | Brand Name | anka | |
Model Number | AJ-6930 |
Product Description
tracking IP 24v addressable photoelectric smoke alarm
Technical specification
1. Executive standard: GB4715-2005
2. Operating voltage: 24V (pulse modulation)
3. Operating current: <300uA (monitoring status) or <1.5mA (alarm status)
4. Work indication: The red indicator will blink in the monitoring status or remain lit in the alarm
status.
5. Weight: about 70g
6. External dimensions: diameter: 100mm, height: 55mm (with the base)
7. Wiring method: non-polarity two-bus system (L1, L2)
8. Operating environment: Indoor, temperature: -10℃~+55℃; relative humidity: ≤95% (40
℃±2℃, without condensation)
9. Coding mode: It can realize electronic coding via coder in situ. Address codes 1 to 324 are
available for selection.
10. Installation height: ≤12m
11. Protection area: about 60m2. For details, see related provisions in GB50116-98 Code for
Design of Automatic Fire Alarm System
12. Matched host machine: fire alarm control panel (such as AJ-MN300)
Item | Describe |
Power | DC 24V |
Standby current | ≤300μA |
Alarm current consumption | ≤1.5mA |
Dimension | 100*46mm |
Specific installation and debugging methods:
1. Make sure the type of the detector matches the type of the host machine of the fire alarm
control panel;
2. Use two M4 screws to fix the matched mounting base on the designated position via the
mounting holes C and D shown in Fig.5, as instructed in the construction drawing and make
sure the matched mounting base has been firmly installed.
3. Use a coder to make the detector coded according to the detector address on the construction
drawing.
4. Disconnect the power supply of the fire alarm control panel and connect the detector correctly
according to the construction drawing.
5. Place the indicator at position A of the detector (see Fig.1) and position B of the base (see
Fig.5), align them with each other, insert the detector into the base and turn the detector
clockwise until it is firmly locked.
6. After all the products are installed and checked, connect the power supply of the fire alarm
control panel and conduct automatic login.
7. When automatic login is success, the red indicator of the detector will blink once about every 12
seconds, which suggests that the detector has begun to operate normally.
8. Finally conduct an alarm test for the detector through some special tools or direct smoke
blowing. After the detector gives a fire alarm, the indicator will remain lit and the fire alarm
control panel will simultaneously show corresponding alarm prompt information. After the alarm
test, reset the fire alarm control panel and restore to the monitoring status.
Our Services:
1. We guarantee that all our items are "as stated" in their descriptions. We strive for 100% customer satisfaction on every sale we complete.
2. We are manufacture, there is no middle man, no high markup, so we can provide quality items yet very competitive price.
3. If you have any questions please contact us first, most are responded with in 12 business hours
Shipmet
1, all package can sent by FedEx/DHL/UPS/EMS, based on customer requires.
2, Freight By Sea to Any nearnest port of customer country.
3, Freight by Air to airport of import country.
Paymnet:
1. T/T
2. West Union
3. Trade Assurance
4. Paypal
FQA
1.Quality of our company.
We are the manufacturer of alarm system for more than 10 years, we are full of experience and technology.
2. Quality of our products.
Our engineers who ever worked in a very famous company of alarm system, all the products must be strictly inspected before selling.
3.Quality of our services.
All of our products have a full two-year warrantyand low repair rate.
4.Quality of our shippment.
We arrange the shippment as soon as we get the payment, fastly and professionally.
5.Quality of our sales representatives.
Truly, Warmly, Patiently, Professionally.
Clear picture
Contact Us
- Anka Sci-Tech Co., Limited
- Contact nameJack Ye Chat Now
- Phone086-0755-89603006-801
- Address3fl, A building, No.4, First Rd, Shangxue Tech Park Bantian ,Longgang District, Shenzhen,518129, P.R.China, Shenzhen, Guangdong
Product Categories
New Products
-
ANKA best selling standalone ionising smoke alarms AJ-709
-
popular battery powered ionization smoke alarms AJ-709
-
ceiling mounted standalone ionization smoke alarms AJ-709
-
battery powered standalone ionization smoke sensor AJ-709
-
high quality ceiling mounted 220v smoke detector AJ-711
-
househond battery powered 220v conventional smoke detector
-
CE approved top mounted optical smoke alarms
-
household conventional optical 220v smoke alarms
-
Conventional cigarette smoke detector security alarms AJ-711
-
conventional battery powered photoelectric smoke alarms
-
CE approved fire alarm portable smoke detector price for hot sale Quality Choice
-
high quality fire smoke alarm
-
Internet smoke detector 2wired or 4wired smoke sensor
-
CE approved standalone fire alarm
-
CE approved standalone sms smoke alarm
-
Hot!Photoelectric cigarette smoke detector prices with 9V battery
-
conventional photoelectric smoke detector with dustproof
-
cheap outdoor smoke density detector for alarm system
-
wired addressable fire alarm smoke sensor with relay output
-
High sensitivity 9V battery operated photoelectric smoke detector
-
CE Approval Wired Optical Smoke Alarm with Relay Output
-
networking zigbee smoke detector with reply output
-
High quality optical smoke alarm installers
-
Independent smoke detector relay output supplier
Popular Searches
- autonom leds
- activate smoke
- certificate convents
- combine detector
- carbon monoxide & smoke detector
- dc smoke
- dimming and strobing
- designer smoke detector
- equipment convent
- excell smoke
- it smoke
- interconnecting smoke detectors
- mini smoke
- network fire
- optic fire
- outdoor smoke
- pointe panel
- rod smoke
- smoke make
- smoke weld
- steel smoke
- resettable manual call point
- alarm system sms
- alarms waterers
- alarm waterers
- approvals smoke detector
- battery fire
- bell fire
- covert camera smoke detector
- ccd smoke detector
Recommended Products
- IR3 Flame detector Infrared Flame Sensor Fire alarm
- Tanda Reflective Linear Beam Smoke Detector
- GST Conventional Infrared Reflective Beam Fire Smoke Detector
- CST smoke detector CE certified smoke alarm 2 wires fire sensor for conventional fire alarm system YT102
- Ceiling white 2 wires conventional smoke detector photoelectric smoke sensor fire alarm for fire alarm security system
- Factory Price Explosion-proof Point Type Smoke Fire Detector
- Wireless Sounder Strobe Wireless Fire Alarm Sound Flashing Lighting Alarm
- Fire Alarm And FIre Fighting Equipment Input Module Fire Fighting Control
- Fire Pull Station Fire Manual Call Point Wireless Fire Alarm System
- Heat Detector Wireless Fire Alarm And Fire Fighting Security Component
- Wireless Fire Alarm Smoke Detector Fire Detection With Fire Fighting Security Equipment
- Fire Alarm Repeater Floor Displayer 16 Zones Fire Indicator For Fire Evacuation
Find Similar Products By Category
- Security & Protection > Fire Control > Fire Alarm & Smoke Detector
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jack Ye
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile