- Main products: Earth Fault Indicator, Cable Fault Indicator, Overhead Line Ground Fault Indicator, Short Circuit and Earth Fault Indicator, Cable Temperature and Faults Sensor, Industrial Dehumidifier, Temperature and Humidity Controller, Fault Passage Indicator, Remote communication terminal, Smart grid system
Home > Products > Overhead Line Fault Indicator > Overhead type Fault Indicator and Wireless communication module
Overhead type Fault Indicator and Wireless communication module
- Shenzhen
- T/T Other
- 7 days
You May Like
-
Flag type Overhead type Short circuit &Ground Fault Indicator
-
Chinese factory Overhead Line cable Fault Locator
-
overhead Line fault indicator for installation methods and tools
-
short circuit and earth fault passage indicator with good price
-
overhead line fault sensor and control communication system
-
overhead line fault sensor and control communication system
Product Description
Overhead type Short circuit &Ground Fault Indicator
Description
SNV series overhead type Fault Indicator system is based on the Sensor that through CT get the (10KV-50KV) line’s current signal, through smart computer chip by program calculating, Analysis ,judge the short circuit or ground fault. When Sensor detect the fault happen, then the Fault indicator warn the manager through turn red flag, and shine red led. It is good for power managing user to find the fault happen reason and place, then fast solve the problem and make the power restore.
SNV Fault Indicator with the aid of the professional control terminal equipment and Web server, it can achieve to remote read and manage the Fault indicator state on times.
There are two channels for reading and managing the remote fault indicators. One is through GSM mobile phone SMS command control. Second is user computer software control. Power managing user, can get the fault indicator information on times
Working principle and structure
One: Fault indicator sensor
TypeQ?/span>SNV308 Indicator
Description
SNV Indicators suitable for overhead lines with a 50KV below four remotes short circuit &Earth fault indicator, through measuring the current of a cable, to judge the fault on the power lines according to the change of current, grounding fault, and the fault state, real time current, battery voltage and other information is uploaded to the remote server, which provides reliable data for the various types of fault diagnosis and location of overhead lines
Character:
l real-time sampling of current per cyclel ultra low power real-time samplingl When line current value?Al Sampling accuracy5-20Au1.5Al Sensor factory automatic calibration, to ensure consistencyl intelligent motor control flopQ?/span>
l Support remote, telemetry, remote control, remote adjustFunction character
a. real time measurement of three-phase on line currentb. Detection and judgment of short circuit faulta) support the determination of the set threshold, fault current, short circuit faultb) supports the determination of a set of mutated incremental currents for short-circuit faultsc) supports the determination of the percentage of short circuit faults that can be set by the percentage of mutated currentsd) support for reclosing identificationc. Detection and judgment of ground faultd. Data Upload functiona) periodically upload real-time online current, zero sequence current, and battery voltageb) Upload the fault status, the fault elimination status and the fault current value in real timee. Parameter setting
a) Available to change the parameter setting through Web server.
b) Available to change and set the parameter though remote setting control PDAQ?/span>
c) Support RS232 port for parameter modification and maintenancef. Support setting controller (PDA)
a) Available reading and change setting parameterb) PDA can read Indicator sensor state , Real time line current, battery voltage data.
c) PDA can simulate the online fault test through setting Indicator’s parameter.
g. Intelligent motor control flop to red flagh. Six three-color fault indicating ledQ?/span>(red, green, blue)
i. One yellow state led lightQ?/span>
j. Support line CT power charge for batteryk. Support timing reset, power on auto reset, remote resetl. can be efficiently mounted and unloadedm. The structure parts are made of antirust and anticorrosion materialn. In waking up state(wireless setting model),During 7 minutes, without operate, there will be auto reset.Function display
Flag state
1) Normally, Flag is on blanket position. Every 3hour, Flag will reset one times for avoiding un fault turn to red flag.
2) When short circuit fault happen, it will turn to red flag state; After reach reset time or when the line current restore, Fault indicator will turn back to blanket state;
3) when the earth fault happen, it will turn to red flag state. It will be automatically turn back blanket state when line power off and current restore, or wait until reach reset time.
Fault indicating Led lightQ?/span>
1) short circuit permanent fault indicating: Six 3-color led will shine red color, and four times, every 2 second?/span>
2) short circuit temporary fault indicating: Six 3-color led will shine green color, and four times, every 2 second?/span>
3) Earth Fault indicating3-color led will shine Blue color, and four times, every 2 second. And turn to red flag at same time.
yellow state Led lightBattery voltage too lowBattery voltage low shine 2 time, evey2second
Wireless setting state: shine 4 times, every 2 second
Two: Setting Controller(PDA)
Type: SNV306-Remote control PDA
Description:
PDA is a setting controller, it use for wireless remote to set and change Fault indicator sensor and Control terminal parameter.
PDA have the function to read the Fault indicator real time state, such as: line current and Fault indicator battery voltage.
At same time, user can do the fault indicator one line test through PDA.
Three: Control Terminal
Type: SNV309-communication terminal RTU
Control terminal is use for the communication between the fault indicator , GPS satellite and web server or user GSM mobile phone. There need insert a SIM card with GPRS and GSM function.
First, Fault indicator will auto upload information to Control Terminal real time through 433M wireless communication..
Second, When user use mobile phone, send SMS command to control terminal, then terminal will execute command and send Corresponding information to user mobile phone.
Third, When the control accessed with web server, the terminal will upload all information to web sever. User can read and manage the all the accessed fault sensor state real time through run a professional software on computer. Computer required connected with internet.
Fourth, GPS Function, when the terminal put outside, then the GPS antenna will connect with GPS satellite and terminal will get the GPS position, longitude and latitude value.
Four: Software system
Type Q?/span>SNV10000 Software APP
SNV software is a professional APP use for reading and managing fault indicators.
User run the APP, then login and accessed with web sever. It is a convenient and intuitive interface. We can directly watch the current chart real time, and history current chart.
Then below is some of the software Page screenshot.
Contact Us
- Zhuhai City Snova Technology Co., LTD
- Contact nameAndrewmao Chat Now
- Phone86-13570657698-8621065
- AddressXiangzhou district, Zhuhai, Guangdong
Product Categories
New Products
-
Installation adapter of Overhead Line Fault Indicator
-
Flag type Overhead type Short circuit &Ground Fault Indicator
-
Simulated Failure Remote Controller for Overhead Line Fault Indicator
-
Electric Power Overhead type Cable Fault Indicator
-
how to reset overhead line earth fault indicator
-
Current Temperature And Faults On-line Monitoring instrument
-
Overhead type Fault Indicator and Wireless communication module
-
short circuit and earth fault indicator distribution system
-
Overhead Cable Fault Warning Device
-
Overhead power line fault indicator with Three color light display
-
15-55KV Overhead type Short circuit &Ground Fault locator
-
Electric Power Overhead Line Current Fault Indicator
-
communication terminal of overhead line fault indicator
-
earth fault indicator distribution system
-
Overhead Line cable Fault Locator
-
Overhead Line High Voltage Line fault locator Device
-
communication terminal of overhead line fault indicator
-
Ин(xi)иaатор замыaания на земxю и aоротaоCо замыaания
-
Flag type Overhead type Short circuit &Ground Fault Indicator
-
Ин(xi)иaатор замыaания на земxю и aоротaоCо замыaания
-
Ин(xi)иaатор замыaания на земxю и aоротaоCо замыaания
-
Ин(xi)иaатор замыaания на земxю и aоротaоCо замыaания
-
EKI4 Current Cable Short Circuit And Grounding Fault Locator
-
Triphase Electric Power Monitor
Popular Searches
Recommended Products
- WAGO original German Wanke 2006-1301 ordinary spring terminal block with three wires and 6 square meters
- WAGO Germany Wanke 280-901 front terminal block 2-wire self-locking spring rail mounted 2.5 square meters
- German WAGO genuine Wanke 2001-1301 three wire rail mounted self-locking spring terminal block 1.5mm square
- Qty:100pcs 2Way GROUND TERMINAL BLOCKS 800V WAGO 2002-1207 2.5MM
- Replace 173682-1 male housing terminal connector new and original
- Replace 173681-1 Female terminal housing terminal
- Wago 2002-1204 Terminal Block, 2.5 MM
- 100 Pack Wago 2002-1201 TopJobs 2-Conductor Feed Through Terminal Block Grey
- CNSDI 125A Busbar Chassis with 6way 8way 10way for Distribution Board
- CNSDI Compact Design 160A Din Rail Pan Assembly with 6way 8way 10way for Distribution Board
- Explosion-Proof Slip Ring Ex-proof slip Ring for Oil and Gas Drilling
- High-speed hybrid slip ring with fiber optic and Ethernet Military-grade fiber optic rotary joint ORJ for UAVs
Find Similar Products By Category
- Electrical & Electronics > Connector & Terminals > Terminals
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andrewmao
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile
We will contact you as soon as possibleQ?/p> Continue View