Home > Products > High Pressure Volumetric Adsorption Analyzers > M-Sorb 2500 medium pressure adsorption analyzer
M-Sorb 2500 medium pressure adsorption analyzer
- Shanghai
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
You May Like
-
V-Sorb 2800 surface area and mesopore analyzer
-
V-Sorb 2800P BET surface area and micropore analyzer
-
V-Sorb 2800S surface area analyzer
-
V-Sorb 2800TP surface area and pore size distribution analyser
-
V-Sorb 4800 BET surface area and pore volume analyzer
-
V-Sorb 4800P surface area and pore size analyzer
Product Details
Brand Name | Gold APP Instruments | Place of Origin | China | |
Model Number | M-Sorb 2500 |
Product Description
M-Sorb 2500 medium pressure adsorption analyzer introduction
Gas adsorption analysis is important in many fields of materials, such as energy storage materials, improved catalysts for petrochemical processing, advanced pharmaceuticals and food industries. At present, there is tremendous interest in the development of innovative materials for the transition to renewable energy. The science of gas adsorption has become particularly critical in the advancement of materials for storing fuel gases such as hydrogen or natural gas, as well as for sequestration of greenhouse gases.
The M-Sorb 2500 medium pressure gas sorption analyzer adopts the volumetric technique principle which consists of dosing a known amount of gas adsorptive into measurement tubes where lying samples (such as zeolites, carbon nanotubes, rocks, catalysts, activated carbons, molecular sieve, hydrides etc. ) to be analyzed. When samples reach equilibrium with the adsorbate gas (such as hydrogen, methane, carbon dioxide, nitrogen, argon, krypton etc.), detailed and comprehensive final equilibrium pressures will be recorded automated by software. These data are used to calculate the quantity of gas adsorbed by samples.
This measurement procedure automatically repeated by software under given temperature and pressure intervals until finalized the maximum preselected pressure. Finally, each of the equilibrium point volume adsorbed, equilibrium pressure, absolute pressure etc. data are plotted to produce the isotherm. By using the isotherm data, operators can calculate further more information such as Langmuir fitting isotherm, the adsorption rate curve, PCT (pressure-composition-temperature) or PCI (pressure-composition-isotherm) curve etc.
Pressure-Composition Isotherms (PCI) and Pressure-Composition Temperature (PCT) is one of the most informative sorption measurements. The result is a plot of the equilibrium absorbed gas concentration in the material as a function of pressure and temperature.
Gold APP Instruments medium pressure adsorption analyzer M-Sorb 2500 adopts static volumetric principle to determine adsorption and desorption isotherms under medium pressure (atmospheric to 100Bar) and high temperature (atmospheric to 500 Celsius) with a stainless steel VCR manifolds system, fully automated operation can control system and multi calculation methods, all these guarantee M-Sorb 2500 to produce a highly repeatability and highly precision analysis data.
M-Sorb 2500 medium pressure adsorption analyzer application fields
1. Study and research in high temperature and pressure gas adsorption, supercritical gas performance, microporous materials, hydrogen storage materials, carbon dioxide sequestration, coalbed methane, oil exploration, shale gas etc.
2. Catalysts, molecular sieves, active carbon, carbon nano-tube, porous carbons, metal organic frameworks (MOFs), fuel cell, hydrocarbon and other materials.
M-Sorb 2500 medium pressure adsorption analyzer specifications
1. Analysis Method: static volumetric adsorption principle
2. Versatility: adsorption/desorption isotherms measurement (atmospheric to 500 Celsius), Gibbs supercritical adsorption measurement
3. Data Reduction: Langmuir model regression isotherm, PCT(Pressure-Composition-Temperature) or PCI (Pressure-Composition-Isotherm) diagram/curve/isotherm measurement, TPD(temperature program desorption), Langmuir maximum adsorption constant L and adsorption pressure constant B measurement; Langmuir correction model loading-ratio correlation regression (LCR) isotherm; Ono-Kondo (OK) lattice model isotherm regression; adsorptive gas density and vapor-liquid equilibrium accuracy calculation under different pressures and temperatures
4. Measuring Ranges: adsorption and desorption measurement to 100Bar pressure
5. Accuracy: repeatability errors<3%
6. Temperature Range: cryogenic to 500 Celsius, accuracy±0.1 Celsius
7. Sample Ports: 2 samples analyzing and 2 degassing ( 4 ports option), stainless-steel micro welding sample tubes, software integrated temperature PID adjustment
8. Transducer Accuracy: imported high precision transducers, accuracy can reach 0.05% of F.S. (full-scale), long-duration usage stability is 0.025% of F.S.
9. Ultimate Vacuum: mechanical pump 4x10-2 Pa (3x10-4 Torr), molecular turbo pump system (1x10-6 Pa) is optional
10. Adsorbate Gas: high purity CO2, H2, CH4, N2 or others
11. Specifications: Height 22.05 inches (56cm) X Width 20.87 inches (53cm) X Depth 23.62 inches (60cm); 132 pound (60kg); 220V/5A
M-Sorb 2500 medium pressure adsorption analyzer technical features:
1. Control System: imported VCR interface high pressure pneumatic valve can realize auto on-off within 100Bar, sealing performance is top to 1x10-10 Pa.m3/s, can be used more than 500 million times; programmable logic controller (PLC) system, high integration and sound anti-interference, improve stability and prolong life
2. Analysis Management: parameters be set by Gold APP Instruments software, fully automated, achieved unattended operation at night
3. Manifold System: branded 316L stainless steel thick-walled manifolds, micro welding sealing can reduce dead space largely; metal VCR connection is convenient for installation and uninstallation
4. Safety Measures: M-Sorb asymptotic technology realizes auto gas-charging and degassing, prevents high pressure dangers caused by artificial mis-operation, and also minimizes large differential pressure impact to pressure transducer
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Contact Us
- Gold APP Instruments Corporation Limited
- Contact nameAndy Chat Now
Product Categories
New Products
-
V-Sorb 4800S specific surface area analyzer
-
V-Sorb 4800TP surface area and porosimetry analyzer
-
H-Sorb 2600PCT hydrogen adsorption isotherms determination analyzer
-
H-Sorb 2600PCT H2 adsorption PCT isotherms determination analyzer
-
H-Sorb 2600PCT H2 adsorption PCI isotherms determination analyzer
-
H-Sorb 2600PCT H2 adsorption TPD isotherms determination analyzer
-
G-DenPyc 2900 True Density & Helium Pycnometry Analyzer
-
G-DenPyc 2900 Gas (Helium) Pycnometer Theory and Practice
-
G-DenPyc 2900 density measurement with a helium pycnometer
-
G-DenPyc 2900 porosity determination with helium pycnometry
-
G-DenPyc 3900 Gas Pycnometer and Helium Pycnometers
-
G-DenPyc 3900 Gas Pycnometer for Semi-Solid and Solid Density
-
G-DenPyc 2900 Professional Gas Pycnometer
-
G-DenPyc 2900 Air and Helium Pycnometer
-
G-DenPyc 2900 Fully Automated Gas Pycnometer
-
G-DenPyc 2900 Analytical Grade Pycnometer
-
H-Sorb 2600 Hydrogen Storage Analyzer
-
H-Sorb 2600 High Temperature Hydrogen Storage Gas Adsorption Analyzer
-
H-Sorb 2600PCT High Pressure Gas Adsorption Analyzers
-
H-Sorb 2600PCT Hydrogen Storage Materials and Sorption Analysis Equipment
-
H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption
-
H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption Analyzer
-
H-Sorb 2602PCT Automatic High-pressure Gas Adsorption Analyzer
-
F-Sorb 2400CE Single-Point and Multi-Point Surface Area Measurements
Popular Searches
Recommended Products
- RSDD 590C DC speed regulator 590C/830A manufactured domestically and sold directly by the manufacturer.
- Ansaldo excitation module SPAM035U1D is now available for new orders.
- SSD 590 Dc governor Factory direct sales Multiple speed feedback methods 590C/3800/5/3/0/1/0/00/000
- 590C DC driver Motor speed regulationArmature voltage feedback 590C/0350/5/3/0/1/0/00/000
- Parker 590 driver High torque Encoder feedback board 590C/1500/5/3/0/1/0/00/000
- 125KHZ Smart card(TK4100 EM4200 EM4305 EM4450 T5577 HITAG 1 HITAG 2 HITAG S 256 HITAG S 2048)
- ГOCT6370 Mechanical Impurity for Petroleum Products Tester
- ASTM D97 Multi-Function Automatic Pour Point and Cold Filter Point of Petroleum Products Tester
- ASTM D482 Ash from Petroleum Products Tester Carbon Residue Test Device
- ASTM D2700 Automatic Gasoline Octane Number Tester (Motor Method)
- ASTM D2700 Automatic Convenient Vehicle Gasoline Octane Number Tester
- ASTM D613 Automatic Octane Number and Cetane Number Tester ASTM D2700
Find Similar Products By Category
- Electrical & Electronics > Electronics Stocks

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile