Home > Products > BET Surface Area Analyzer > V-Sorb 4800S specific surface area analyzer
V-Sorb 4800S specific surface area analyzer
- 30 Set / Sets per Month
- Shanghai
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
You May Like
-
V-Sorb 4800TP surface area and porosimetry analyzer
-
H-Sorb 2600PCT hydrogen adsorption isotherms determination analyzer
-
H-Sorb 2600PCT H2 adsorption PCT isotherms determination analyzer
-
H-Sorb 2600PCT H2 adsorption PCI isotherms determination analyzer
-
H-Sorb 2600PCT H2 adsorption TPD isotherms determination analyzer
-
G-DenPyc 2900 True Density & Helium Pycnometry Analyzer
Product Details
Brand Name | Gold APP Instruments | Place of Origin | China | |
Model Number | V-Sorb 4800S |
Product Description
V-Sorb 4800S specific surface area analyzer introduction
V-Sorb 4800S specific surface area analyzer is for surface area determination which utilizes static volumetric method. Analyzer be designed from the user perspective and equipped with fully automated operation and user-friendly interface, all these make it easy to learn. It has 4 analysis stations with quick testing speed, is an ideal tool for production factories who need to control many materials quality every day.
V-Sorb 4800S specific surface area analyzer specifications
1. Analysis Method: static volumetric nitrogen adsorption principle.
2. Testing Abilities: Adsorption and desorption isotherms, Single and multi-point BET (Brunauer-Emmett-Teller) surface area, Langmuir surface area, t-plot external surface area, carbon black STSA etc.
3. Measuring Ranges: 0.01 m2/g (by nitrogen)/ 0.0005m2/g (by krypton) to no known upper limit.
4. Accuracy: repeatability errors ≤1%.
5. Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume of analyzer.
6. Coolant Level Controller: V-Sorb original coolant level control system with temperature probe, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by the dead volume.
7. Sample Ports: four analyzing and four degassing simultaneously.
8. Pressure Measurement: branded pressure transducer, notably improve the measuring accuracy at low P/Po point, two 1000Torr (0-133Kpa) transducers, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale).
9. Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998
10. Ultimate Vacuum: 4x10-2Pa (3x10-4Torr)
11. Vacuum Pump: built-in mechanical vacuum pump controlled by software which can auto control pump’s start/stop
12. Adsorbate Gas: high purity nitrogen(≥99.999%), Ar, Kr, CO2 etc. non-corrosive gases are optional
13. Dimension: Height 22.05 inches (56cm)* Width 20.87 inches (53cm)*Depth 23.62 inches (60cm); 132 pound (60kg)
V-Sorb 4800S specific surface area analyzer technical features
A: Vacuum System
1. Unique integral manifolds system, decrease connecting points apparently, reduce leak rate, improve ultimate vacuum.
2. Modularity design can configure as customer requests, benefits future functions extension and instrument maintenance.
3. Branded vacuum pump, low noise, stable working, oil-return prevention; ultimate vacuum can reach 4x10-2Pa (3x10-4Torr).
B: Control System
1. Industry programmable solenoid valve system, strong anti-interference ability, convenient for installation and uninstallation.
2. Separated analysis and pretreatment/degassing manifolds system can prevent foreign matter to contaminate manifolds during samples pretreatment.
C. Measures for Improving Accuracy
1. Imported pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S. (full-scale).
2. The 1000Torr pressure transducer, sectional measurement in pressure range can reduce errors in low vacuum, 10Torr (option) transducer is highly accurate than Pirani resistance vacuum gauge (general error is 10%-15%).
3. Unique monolithic manifolds system, decrease connecting points and reduce leak rate apparently.
4. Original stepping coolant level control system, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by the dead volume.
5. Pioneered gas outlet and inlet control system can efficiently prevent sample splash in evacuation and gas inlet process, guarantee clean manifolds and sample weight unchanged, avoid zero and liner drifting caused by transducer’s macro-change.
D. Data Acquisition and Reduction
1. High precision and integration data acquisition module is easy to connect, minimal errors and strong anti-interference ability; standard 485 communication mode is good for analyzer’s applications extension and interconnection, can also conveniently switched to RS232 or USB modes.
2. Multi calculating formulas for data reduction provides all-round sample analysis options; powerful data archiving and searching system helps a lot for data management.
V-Sorb 4800S specific surface area analyzer application fields
1. For powder, nanomaterial, particle and fiber etc. materials specific surface area analysis.
2. Products quality control for production fields, like carbon black, catalysts, sieve and so on.
3. Research institutes, universities for BET (Brunauer-Emmett-Teller) surface area theory teaching.
4. Other researches concern specific surface area (single point BET, multi point BET, Langmuir surface area, t-plot surface area etc.) performance.
visit more from www (dot) goldapp (dot) com (dot) cn
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Contact Us
- Gold APP Instruments Corporation Limited
- Contact nameAndy Chat Now
Product Categories
New Products
-
G-DenPyc 2900 Gas (Helium) Pycnometer Theory and Practice
-
G-DenPyc 2900 density measurement with a helium pycnometer
-
G-DenPyc 2900 porosity determination with helium pycnometry
-
G-DenPyc 3900 Gas Pycnometer and Helium Pycnometers
-
G-DenPyc 3900 Gas Pycnometer for Semi-Solid and Solid Density
-
G-DenPyc 2900 Professional Gas Pycnometer
-
G-DenPyc 2900 Air and Helium Pycnometer
-
G-DenPyc 2900 Fully Automated Gas Pycnometer
-
G-DenPyc 2900 Analytical Grade Pycnometer
-
H-Sorb 2600 Hydrogen Storage Analyzer
-
H-Sorb 2600 High Temperature Hydrogen Storage Gas Adsorption Analyzer
-
H-Sorb 2600PCT High Pressure Gas Adsorption Analyzers
-
H-Sorb 2600PCT Hydrogen Storage Materials and Sorption Analysis Equipment
-
H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption
-
H-Sorb 2600PCT High Temperature Hydrogen Storage Gas Adsorption Analyzer
-
H-Sorb 2602PCT Automatic High-pressure Gas Adsorption Analyzer
-
F-Sorb 2400CE Single-Point and Multi-Point Surface Area Measurements
-
F-Sorb 2400CE the single point BET method analyzer
-
F-Sorb 2400CE Brunauer-Emmett-Teller (BET) surface area analysis equipment
-
F-Sorb 2400CE BET Surface Area Analysis of Nanoparticles
-
F-Sorb 2400CE BET Specific Surface Area Testing Equipment
-
F-Sorb 2400CE BET Method Analyser for Determining Surface Areas
-
F-Sorb 2400CE Surface Area Brunauer–Emmett–Teller (BET) Analyzer
-
V-Sorb 4800P BET Surface Area Analysis & BJH Pore Size & Volume
Popular Searches
Recommended Products
- 125KHZ Smart card(TK4100 EM4200 EM4305 EM4450 T5577 HITAG 1 HITAG 2 HITAG S 256 HITAG S 2048)
- ГOCT6370 Mechanical Impurity for Petroleum Products Tester
- ASTM D97 Multi-Function Automatic Pour Point and Cold Filter Point of Petroleum Products Tester
- ASTM D482 Ash from Petroleum Products Tester Carbon Residue Test Device
- ASTM D2700 Automatic Gasoline Octane Number Tester (Motor Method)
- ASTM D2700 Automatic Convenient Vehicle Gasoline Octane Number Tester
- ASTM D613 Automatic Octane Number and Cetane Number Tester ASTM D2700
- ASTM D613 Automatic Diesel Cetane Number Tester
- ASTM D613 Convenient Automatic Diesel Cetane Number Tester
- Automatic Calorific Value for Petroleum Products Tester (Calorimeter)
- ASTM D1322 Kerosene and Aviation Turbine Fuel Smoke Point Tester
- ASTM D189 Conradson Carbon Residue of Petroleum Products Tester
Find Similar Products By Category
- Electrical & Electronics > Electronics Stocks

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andy
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile