HONEYWELL 51196655-100 ACX633
- T/T
- 1 days
You May Like
Product Details
Brand Name | HONEYWELL | Place of Origin | China | |
Model Number | 51196655-100 ACX633 |
Product Description
Brand:HONEYWELL
Type:51196655-100 ACX633
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Set the setpoint initialization value followed by ENTER. When not using the Extr/Adm Enable function, this is the value that the auxiliary setpoint initializes to upon power-up or exiting the program mode. (Must be less than or equal to the ‘Max Extr/Adm Setpoint’ Setting) EXTR/ADM DROOP (%) dflt= 0.0 (0.0, 100) Enter the droop percentage followed by the ENTER key. If required, typically set between 4-6%. PID PROPORTIONAL GAIN (%) dflt= 1.0 (0.0, 100) Enter the Extr/Adm PID proportional gain value followed by ENTER. This value is used to set auxiliary control response. This value can be changed in the Run Mode while the turbine is operating. If unknown, a recommended starting value is 1%. PID INTEGRAL GAIN (%) dflt= 0.3 (0.001, 50) Enter the Extr/Adm PID integral gain value, in repeats-per-second (rps), followed by ENTER. This value is used to set extr/adm control response. This value can be changed in the Run Mode while the turbine is operating. If unknown, a recommended starting value is 0.3 rps. PID DERIVATIVE RATIO (%) dflt= 100 (0.01, 100) Enter the Extr/Adm PID derivative ratio followed by ENTER. This value is used to set extr/adm control response. This value can be changed in the Service Mode while the turbine is operating. If unknown, a recommended starting value is 100%. TIEBRKR OPEN E/A DISABLE ? dflt= YES (Yes/No) Select YES followed by ENTER if the extr/adm control will be disabled when the utility tie breaker opens. If NO is selected, then extr/adm control will not be disabled when the utility tie breaker is opened.
GENBRKR OPEN E/A DISABLE ? dflt= YES (Yes/No) Select YES followed by ENTER if the extr/adm control will be disabled when the generator breaker opens. If NO is selected, then extr/adm control will not be disabled when the generator breaker is opened. E/A SPEED ENBL SETTING dflt= 1000 (0, 20000) Value of speed as a permissive for enabling Extr/Adm control. The speed must be above this setting before control with be active. USE REMOTE SETTING? dflt=NO (Yes/No) Set to YES to allow the Extr/Adm setpoint to be adjusted from an analog input. (Must program a ‘remote extr/adm setpoint’ analog input) REMOTE SETPT MAX RATE dflt= 5.0 (0.01, 1000) Set the extr/adm setpoint rate followed by ENTER. This value is the rate (in units per second) at which extr/adm setpoint moves when adjusted. EXT/ADM UNITS OF MEASURE (must choose from list) Options: psi #/hr kPa kg/hr kg/cm2 bar t/h atm k#/hr (none) Extraction / Admission Before configuring the extraction/admission map, read the Steam Map description below. This discusses steam maps and how to convert your steam map information into a format usable by the 505E control. The steam map is a graphical representation of the operating range and limitations of an extraction and/or admission steam turbine. This map is often called a steam envelope, since normal turbine operation must be contained within the envelope lines. The 505E uses the values programmed to calculate the turbine’s internal pressure ratios and limits. In order to get these values from your steam map, you must first check the following conditions and, if necessary, modify the map so it meets these conditions: ? The map must be linear (all lines straight). ? Lines extraction/admission flow = 0% and extraction/admission flow =100% must be parallel, and lines LP valve = 0% and LP valve = 100% must be parallel. If your envelope lines are not all straight and parallel (conditions 1 and 2), redraw the envelope so that they are (use graph paper). Make sure your redrawn envelope approximates the old envelope as closely as possible. The lines on the envelope define the operating characteristics of your turbine. Refer to the example steam maps in this manual. The different lines or limits of a Steam map are: ? The horizontal axis shows turbine power (S). ? The vertical axis shows HP valve position (HP). ? The vertical line called S=100 is the maximum power limiter. This limiter prevents turbine operation beyond the maximum power limit. ? The horizontal line called HP=100 is the maximum HP flow limiter. The HP flow limiter prevents turbine operation beyond the desired maximum HP flow limit.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Product Categories
New Products
-
HONEYWELL 51402455-100 MP-DNCF02-201
-
HONEYWELL 51403519-160 K4LCN-16
-
HONEYWELL 51403645-100 SBHM
-
LAM 810-800082-043
-
S21260-SRS
-
IS200SRTDH2ACB
-
IS220PAICH2A 336A4940CSP11
-
IS220PDIAH1A 336A4940CSP1
-
IS220PDOAH1A 3364940CSP2
-
IS220PRTDH1BC 336A5026ADP13
-
IS230SNRTH2A
-
SR469-P5-HI-A20
Popular Searches
- food processor
- log splitter
- network switch
- network hardware
- cisco module
- industrial computer
- poe splitter
- poe
- poe injector
- cisco
- motherboard
- network equipment
- firewall
- video wall processor
- audio processor
- cisco network module
- interface processor
- plug-in module
- route
- led module
- led lighting
- laser machine
- fiber optic
- ftth
- diode
- laser equipment
- laser diode
- laser module
- media converter
- sfp transceiver
Recommended Products
- UFC762AE101 3BHE006412R0101 Control System DCS Spare Parts Spot Goods
- DSMB-01C Spare Parts of Inverter Power Boards for Frequency Converters Fast Delivery Power
- RS-FS-9001 362A1052P404 Spiral Joint Fluid Control System
- Vibro-meter VM600 RPS6U 200-582-200-011 Vibration Sensor Detection System
- TRICONEX 4351B Control Module
- FOXBORO FCP270 P0917YZ Controller Module
- H201Ti Monitor Industrial Control DCS System
- UNITROL 1020 UNS0119A-Z V1 3BHE030579R0003 Excitation Static Controller
- Vibro-meter 200-560-000-018 200-560-101-015 VM600 IOC4T Module/Controller
- EMERSON VE3008 CE3008 KJ2005X1-MQ1 12P6381X042 Industrial Automation System Module
- ALSTOM N897164624A Module/controller Redundancy Positioning System
- ALSTOM N895314513L Data Acquisition Module
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile