Home > Products > blackbody radiation source > DY-HT300M Black body Radiation Source/Infrared Thermometer Calibration Instrument with High stability
DY-HT300M Black body Radiation Source/Infrared Thermometer Calibration Instrument with High stability
- 1111 Piece / Pieces per Month
- Qingdao
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 15 days
You May Like
-
DY-GTL450X Dry Block Temperature Calibrator/High Precision Calibration with Rapid Heating
-
High Precision dry block temperature calibrator/dry block calibrator definition(50-600c)
-
Portable Industrial Precision Dry Block Temperature Calibrator
-
DY-GTL200X Intelligent Portable Dry Block temperature calibrator/ Dry Well furnace china
-
DY-HT200M surface source black body furnace, radiation surface 200MM (room temperature +5℃-300℃)
-
DY-HT2M-150 medium temperature surface source blackbody furnace, radiation surface 150mm (room temperature +5-500℃)
Product Details
Brand Name | DEMEI | Place of Origin | China | |
Model Number | DY-HT300M | Temperature Range | RT+5°C~200°C | |
Usage | Industrial | Theory | Temperature Controller | |
Accuracy | ±0.2°C |
Product Description
Product Introduction
Definition of black body: an object that can absorb all external radiation energy and radiate all its own energy at the same time.
The main technical indicators of black body: emissivity of black body, diameter of black body cavity, temperature uniformity and uncertainty of radiation temperature. Therefore, in order to ensure the product quality of black body, black body is usually designed according to temperature segmentation. Usually what we call black body is artificial black body. The emissivity of artificial black body is close to 1, but not equal to 1.
The main function of black body is to generate standard radiation at a certain temperature. Therefore, it is mainly used to calibrate various radiation thermometers, such as optical pyrometers, infrared thermometers, infrared thermal imagers, etc. in temperature measurement.
Black body is mainly used in the field of temperature measurement in industry, and the main product is black body furnace. For the calibration and verification of radiation thermometer, the comparison method is usually used, that is, through a high-stability radiation source (usually a black body radiation source) and other supporting equipment, the temperature reproduced by the standard instrument is compared with the temperature reproduced by the radiation thermometer to be tested to determine whether it is qualified or give a calibration result.
As a standard radiation source, standard black bodies are mainly used to calibrate radiation thermometers, infrared thermometers and radiation temperature sensor detectors. Our company currently has advanced black body technology, a full range of black body products with a wide temperature range. The products are small in size, light in weight and easy to carry. They are not only suitable for calibrating radiation thermometers in laboratories of metrology institutions at all levels, but can also be used for on-site calibration.
Product Application
The surface source blackbody radiation source is the infrared radiation working standard. It is widely used in the process test and technical index test of the identification test in the development process of infrared detectors. It can complete the test of parameters such as the uniformity of the photosensitive surface response, response curve and dead pixel of the infrared focal plane device. At the same time, the surface source blackbody radiation source, as the core equipment of the infrared imaging prism device, cooperates with the infrared collimation optical system and infrared target to complete the key technical index test and performance evaluation of the infrared imaging system. It can meet the test needs of the infrared imager in the newly developed infrared imaging guided weapons in my country, and can meet the test needs of infrared thermal imagers widely used in medical, construction, security monitoring, environmental testing and other industries.
Product Features
1. More portable and lighter. Higher precision.
2. Human-machine interface, Chinese display, touch operation, beautiful and elegant.
3. One-key temperature setting, simple operation. Rapid heating and temperature control.
4. According to customer requirements, the language interface of multiple countries and regions can be copied for easy export.
Product Advantages
1) The appearance is novel and the furnace and temperature controller are integrated.
2) The heating element is insulated from the shell, and special software is used for pressure-limited heating, so no high-power power transformer is required.
3) Automatic temperature rise and temperature control is adopted, which is safe and reliable, with fast heating speed and good temperature stability.
4) It is easy to use and operate, small in size and light in weight, easy to carry, and is not only suitable for laboratory calibration, but also for on-site calibration.
5) Large surface source isothermal blackbody radiation surface, the factory default emissivity is 0.95, and the emissivity can be adjusted between 0.96-1 if different emissivities are required.
6) The screen has built-in multi-point independent temperature correction function.
7) Automatic intelligent adjustment: Contains MH logic intelligent adjustment function, and advanced control algorithm for parameter self-tuning function.
8) Program control function, the equipment has 10 groups of different program setting interfaces reserved, one-key operation, convenient and fast, meeting the user's requirements for multiple detection points and improving the user's detection efficiency.
9) The communication interface can be customized RS232.
10) The device has a memory function, which allows it to quickly restore to the previous setting state after restarting, without the need for additional settings to start.
Product Parameters
Working temperature | RT+5°C~300℃ |
Operation mode | Touch screen operation |
Temperature resolution | 0.1℃ |
Temperature control | PID automatic control |
Radiation surface | Φ300mm |
Cavity emissivity | ≥0.95 |
Temperature stability | ±(0.1~0.5)℃/10min |
Temperature uniformity | ±0.5℃@100°C (in 2/3 center area) |
Power supply | 220V AC 50/60Hz 10A |
Volume (length×width×height) | 402mm×310mm×550mm |
Product photos
If you have any questions,please feel free to contact us!
Tel: +86 186 5382 5886
Wechat:demeicalibrator
Email: sales@dmthermo.com
Contact Us
- Taian Demei Electromechanical Equipment Co.,LTD.
- Contact nameMia Chat Now
- Phone86-0538-6518016-019
- AddressTaishan District, Tai'an, Shandong
Product Categories
New Products
-
DY-HT1M-150 low temperature surface source black body furnace, radiation surface 150mm (-20-100℃)Infrared Thermometer Calibration Instrument
-
DY-HT50M portable blackbody furnace, radiation surface 50mm (room temperature +5℃-500℃)/Infrared Thermometer Calibration Instrument
-
DY-BO1 high precision zero point thermostat 0oC±0.03oC Dry Block temperature calibrator/ Dry Well furnace
-
DY-HT2M surface source blackbody furnace radiatiosurface 100mm (room temperature +5℃-500℃/600℃)/Infrared Thermometer Calibration Instrument with High stability
-
DY-GTL450X Dry Block Temperature Calibrator/High Precision Calibration with Rapid Heating
-
High Precision dry block temperature calibrator/dry block calibrator definition(50-650°C)
-
DY-BM01 Surface Thermometer Calibration Furnace
-
DY-RTS80 high-precision refrigeration constant temperature bath (-80℃-105℃)
-
Laboratory High Precision Thermocouple Calibration Furnace/ Thermocouple Calibration Furnace
-
DY-JDL600 High-temperature thermocouple calibration tube furnace
-
DY-HT1M low temperature surface source black body furnace, radiation surface 100mm (0℃-80℃/100℃, -20℃-80℃/100℃)
-
DY-WDJ High-precision digital thermometer
-
DY-JDL600 Thermocouple calibration furnace(300-1200c)
-
DY-69 high-precision digital thermometer (-50~450℃)
-
DY-07 Handheld high-precision digital thermometer
-
DY-HT70MD portable intelligent multi-faceted blackbody furnace (room temperature +5°C~150℃)
-
Laboratory High Precision Thermocouple Calibration Furnace/ Thermocouple Calibration Furnace
-
DY-07 Handheld high-precision digital thermometer
-
Laboratory High Precision Thermocouple Calibration Furnace/ Thermocouple Calibration Furnace
-
DY-HT1-Y Low temperature bath black body radiation source
-
DY-GTL450X Dry Block Temperature Calibrator/High Precision Calibration with Rapid Heating
-
DY-HT2 Cavity blackbody radiation source
-
Laboratory High Precision Thermocouple Calibration Furnace/ Thermocouple Calibration Furnace
-
DY-GTLB Transformer Oil Level Thermometer Detection Device (-20℃-150℃)
Popular Searches
Recommended Products
- Smart Type Pressure Transmitter PMP71 Pressure Transmitter Oem Pressure Sensor
- LCD Electromagnetic Flowmeter 5HBB50 Proline Promag H 10
- ThermoProbe TP7-D Intrinsically Safe Portable Electronic Thermometer
- Intelligent all-in-one temperature transmitter
- Dixell electronic expansion valve controller XEV32D-1N1C0 stepping driver
- Dixell digital scroll solenoid valve controller XEV02D-5P1B0B driver Copeland digital scroll compressor
- Dixell digital scroll controller XC35CX-5B33H thermostat 230V
- Dixell heat pump chiller controller IC261L-10110 main control board 24V
- Carel programmable controller PRK300L0F0-C control board PGN1000F00
- NANBEI Laboratory BTC-706 High and Low Temperature Testing Chamber
- Endress+Hauser Temperature transmitters
- DY-GTLB transformer oil level thermometer detection device (-20℃-150℃)
Find Similar Products By Category
- Instruments & Meters > Meter for Liquid & Gas > Thermometer & Hygrometer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Mia
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile