Brand Name | DA YAO | Place of Origin | China | |
Model Number | DY-JDL600 | Temperature Range | 300-1200c | |
Usage | Industrial | Theory | Temperature Controller | |
Accuracy | ±0.5c |
Product Description
DY-JDL600 Thermocouple calibration furnace
1.Overview:
DY-JDL600 Thermocouple calibration furnace is a kind of electric heating system providing heat energy for thermocouple.It is made up of heating element and insulation layer.Calibration furnace can be divided into two types,namely,furnace vertical and horizontal furnace.Based on shape-appearance,it can be divided into a short one and a long one.
2.Range:
This calibration furnace contains horizontal and tubular type with or without thermostat,capable of offering temperature field (300℃-1200℃). It is used for calibrating standard thermocouple or thermal resistance.Thereinto,noble metal thermocouple calibration furnace,base metal thermocouple calibration furnace and short thermocouple calibration furnace are included.
3.Verification regulation:
JG351-1996《Verification regulation of base metal thermocouple》
JJG75-95《Verification regulation of standard platinum-rhodium 10 and platinum thermocouple》
JJG141-2000《Verification regulation of noble metal thermocouple》
4.Product model and technical parameters:
Model | DY-JDL600 |
Temperature range | 300-1200℃ |
Heat source | electric heating |
Uniform temperature field | The axial deviation between the center of maximum uniform temperature field and geometric center is no greater than 10mm. The length of uniform temperature field is no less than 60mm, difference in temperature ≤1℃.
|
Axial temperature field | ≤±0.5℃ |
Radial temperature field | ≤±0.4℃ |
Furnace length | 600mm |
Furnace mouth | 40mm |
Overall dimension | 625×300×360 |
Power consumption | 1000w |
Power supply | 220V 50HZ |
5.Preparation before testing:
u Check the inner tube in the furnace before testing. Crack and obvious deformation is not allowed.
u Before plugging in, Use digital multipurpose meter to measure the resistance value of heater strip under normal temperature. Usually,it should be several ohm to more than ten ohm.
u With regard to calibration furnace laid aside for a long time.If necessary,drying oven process in advance is a must.
6.Testing method:
u When heating-up, its power consumption should be controlled at 8A or so. In a general way,it takes 90 minutes to rise to 1000 centigrade.Test begins when it is stable (usually 60 minutes).
u Preparation before testing.Alundum tube should be clean and pollution-free.Quartz tube and refractory materials used in base mental thermocouple calibration furnace is not allowed to be used in noble mental thermocouple calibration furnace.
u Use straight scale to measure the distance from one end to the other and calculate the central point of calibration furnace. On the insulating tube,calculate the central point from business end.Cover the standard thermocouple with high aluminum protective tube.And the thermocouple that is being calibrated should be covered with high aluminum porcelain bead. Use fine nichrome wire to bundle these two thermocouples into circular shape.Its diameter is no greater than 20mm.
u When bundling up, make the measuring terminal of thermocouple that is being calibrated circle around the measuring terminal of standard thermocouple and let it vertically lie in the same cross section of standard thermocouple.
u Put the bundled thermocouple into the inside of tubular furnace.And the measuring junction of thermocouple should be in the geometric center of tubular furnace’s high temperature region. Standard thermocouple has to be in the axial position of tubular furnace. The reference end of these two thermocouple must be put into the same freezing point thermostat.The depth of immersion should be same,approximately 100-150mm.
u The temperature in the furnace must be controlled at a level that is close to the temperature points for testing. The difference it deviates from temperature points for testing should be no greater than ±5℃.When temperature variation meets the requirements of 0.2℃/min, measurement can be started. For further details of measurement and operation ,Please refer to the JJG351—1996 verification regulation of base mental thermocouple.
If you have any questions,please feel free to contact me.
Tel:+86 186 5382 5886
Email:tadmjd3@gmail.com
Contact Us
- Taian Demei Electromechanical Equipment Co.,LTD.
- Contact nameMia Chat Now
- Phone86-0538-6518016-019
- AddressTaishan District, Tai'an, Shandong
Product Categories
New Products
-
DY-GTL800XA Portable Touch-screen Dry Block Temperature Calibration
-
DY-HT4 Cavity Blackbody Radiation Source
-
DY-CTRE200 Intelligent Dry Block Analyzer
-
DY-JDL600 Cheap Metal thermocouple calibration furnace (300℃-1200℃)
-
DY-XJY Portable Multi-Channel Temperature and Humidity Field Testing System
-
DY-XJY01B Portable Multi-Channel Temperature and Humidity Field Testing System
-
Portable Multi-Channel Temperature and Humidity Field Testing System
-
DY-JDL1600 Laboratory Temperature calibration thermocouple calibration furnace(800-1600°C)
-
DY-GTL1200XA Portable Touch-screen Dry Block Temperature Calibration
-
DY-HT2M-70 small size high precision surface source blackbody furnace (radiation surface 70mm)
-
DY-HT4-1 Blackbody furnace/blackbody radiation source (800℃-1450℃)
-
DY-GTL650X High Precision Dry Block Temperature Calibrator/Dry Block Calibrator Definition High Temperature
-
DY-XJY01B Portable Multi-Channel Temperature and Humidity Field Testing System
-
DY-WSX02 Temperature and Humidity Test Chamber
-
DY-WSX01 Temperature and Humidity Calibration Chamber/Temperature and Humidity Test Box
-
DY-WSX01 Temperature and Humidity Calibration Chamber/Temperature and Humidity Text Chamber
-
DY-HTY Special blackbody radiation source for portable thermometer
-
DY-HT1M-70 small size high precision surface source blackbody furnace (radiation surface 70mm)
-
DY-HTX1 Blackbody Radiation Source for Thermal Image Public Entrance Temperature Test
-
DY-GTL150X Hot Selling Portable Dry Well Furnace Dry Block Temperature Calibrator Sensor Calibration for Lab
-
DY-HT1 Cavity blackbody radiation source
-
DY-LD01 Chilled mirror dew point meter
-
DY-WSX01A Temperature and Humidity Calibration Chamber/Temperature and Humidity Test Box
-
DY-HT3 Cavity blackbody radiation source
Popular Searches
- recorder
- thermometer hygrometer
- bath thermometer card
- data measurement
- temperature data logger
- digital thermostat
- fan thermostat
- control thermostat
- temperature recorder
- temperature humidity data logger
- data recorder
- humidity data logger
- usb data logger
- temperature sensor data logger
- temperature recorder data logger
- sms alarm data logger
- usb temp data logger
- thermometer data logger
- temperature monitor data logger
- wireless data logger
- external probe data logger
- data logger
- humidity sensor data logger
- power meter data logger
- temperature thermostat
- gps logger
- remote control thermostat
- gprs data logger
- usb recorder
- digital thermometer fork
Recommended Products
- High-Performance PC4 Dual-Spectrum PTZ Security Camera with 12μm Uncooled Infrared Detector for 24/7 Monitoring
- Compact Infrared Speed Dome Security Camera with 20× Zoom and AI Human Detection
- Smart Dual-Spectrum PTZ Security Camera with 256×192 Thermal and 5MP Visible Resolution
- Portable Thermal Imaging Camera with 640×512 Resolution and RJ45/RS485/PoE/USB for Easy Integration
- Compact Infrared Thermal Camera with 12μm Detector and 25Hz Frame Rate for Real-Time Monitoring
- Ultra-High Temperature Thermal Camera with 640×512 Infrared Resolution and 0~2000°C Measurement Range
- USB-Compatible Smart Thermal Camera with H.265 Video Output and Onboard SD Card Storage
- Smart AI-Powered Thermal PTZ Security Camera with Tripwire and Intrusion Detection for Critical Infrastructure Protection
- Advanced PTZ Thermal Security Camera with -40℃ to +70℃ Wide Temperature and IP66 Weatherproof Protection
- Compact Multi-Spectrum Security Camera with 360° PTZ Rotation and 1280×1024 Thermal Imaging Resolution
- Portable Long-Range PTZ Security Camera with 30–225mm Thermal Lens and 15–775mm HD Optical Zoom
- High-Definition Multi-Spectrum PTZ Security Camera with 3km Laser Illuminator and Intelligent Fire Detection
Find Similar Products By Category
- Instruments & Meters > Meter for Liquid & Gas > Thermometer & Hygrometer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Mia
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile