Home > Products > Pressure Composition Isotherm Analyzer > pressure composition temperature isotherm equipment supplier
pressure composition temperature isotherm equipment supplier
- T/T L/C D/P D/A
- 7 days
You May Like
Product Details
Brand Name | Gold APP Instruments | Place of Origin | China | |
Model Number | H-Sorb 2600 |
Product Description
H-Sorb 2600 high pressure gas adsorption volumetric principle analyzer introduction
Gas sorption analysis is important in many fields of materials, such as energy storage materials, improved catalysts for petrochemical processing, advanced pharmaceuticals and food industries. At present, there is tremendous interest in the development of innovative materials for the transition to renewable energy. The science of gas sorption has become particularly critical in the advancement of materials for storing fuel gases such as hydrogen or natural gas, as well as for sequestration of greenhouse gases.
The H-Sorb 2600 high pressure gas sorption analyzer adopts the volumetric technique principle which consists of dosing a known amount of gas adsorptive into measurement tubes where lying samples (such as zeolites, carbon nanotubes, rocks, catalysts, activated carbons, molecular sieve, hydrides etc. ) to be analyzed. When samples reach equilibrium with the adsorbate gas (such as hydrogen, methane, carbon dioxide, nitrogen, argon, krypton etc.), detailed and comprehensive final equilibrium pressures will be recorded automated by Gold APP Instruments company dedicated and patented software. These data are used to calculate the quantity of gas adsorbed by samples. This measurement procedure automatically repeated by software under given temperature and pressure intervals until finalized the maximum preselected pressure. Finally, each of the equilibrium points’ volume adsorbed, equilibrium pressure, absolute pressure etc. data are plotted to produce the isotherm. By using the isotherm data, operators can calculate further more information such as Langmuir fitting isotherm, the adsorption rate curve, PCT (pressure-composition-temperature) or PCI (pressure-composition-isotherm) curve etc.
Pressure-Composition Isotherms (PCI) and Pressure-Composition Temperature (PCT) is one of the most informative sorption measurements. The result is a plot of the equilibrium absorbed gas concentration in the material as a function of pressure and temperature.
Gold APP Instruments high pressure and high temperature gas sorption analyzer H-Sorb 2600 adopts static volumetric principle to determine adsorption and desorption isotherms under high pressure (atmospheric to 200Bar) and high temperature (atmospheric to 500℃) with a stainless steel VCR manifolds system, fully automated operation can control system and multi calculation methods, all these guarantee H-Sorb 2600 to produce a highly repeatibility and highly precision analysis data.
H-Sorb 2600 high pressure gas adsorption volumetric principle analyzer parameters
Analysis Method: static volumetric principle, high pressure gas sorption principle
Versatility: adsorption/desorption isotherms measurement (atmospheric to 500℃), Gibbs supercritical adsorption measurement
Data Reduction: Langmuir model regression isotherm, PCT(Pressure-Composition-Temperature) or PCI (Pressure-Composition-Isotherm) diagram/curve/isotherm measurement, Langmuir maximum adsorption constant L and adsorption pressure constant B measurement; Langmuir correction model loading-ratio correlation regression (LCR) isotherm; Ono-Kondo (OK) lattice model isotherm regression; adsorptive gas density and vapor-liquid equilibrium accuracy calculation under different pressures and temperatures
Measuring Ranges: continuous adsorption and desorption measurement from atmospheric to 200Bar pressure
Accuracy: repeatability errors <3%
Temperature Range: cryogenic to 500℃, accuracy±0.1℃
Sample Ports: two samples analyzing and two degassing, stainless-steel micro welding sample cells, software integrated temperature PID adjustment
Transducer Accuracy: imported high precision transmitter, accuracy can reach 0.05% of F.S. (full-scale), long-duration usage stability is 0.025% of F.S.
Ultimate Vacuum: 4x10-2 Pa (3x10-4 Torr), molecular pump system (1x10-6 Pa) is optional
Adsorbate Gas: high purity nitrogen, CO2 or others (Ar, Kr, H2, CH4 etc.)
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Contact Us
- Gold APP Instruments Corporation China
- Contact nameGoldAPP Instruments Chat Now
- Phone86-10-82132122
- AddressFloor 6th, Tianli Building, No. 56th, Zhichun Rd., Haidian Dist, Beijing 100098, Liaocheng, Shandong
Product Categories
New Products
-
high pressure gas sorption measurement
-
porosimetry measurement, porosimetry ppt, porosimetry BET
-
high pressure hydrogen adsorption apparatus
-
high pressure hydrogen adsorption in the zeolites
-
high pressure CH4 and CO2 sorption isotherms
-
high pressure methane adsorption, high pressure methane and carbon dioxide adsorption
-
high pressure methane adsorption in the metal-organic-frameworks
-
hydrogen and methane adsorption in metal-organic frameworks
-
High-Pressure Adsorption of Methane and Ethane in Activated Carbon and Carbon Fibers
-
adsorption in porous meterials at high pressure
-
high pressure adsorption equilibria of methane and carbon dioxide
-
high-throughput single point BET analyzer
Popular Searches
- sulfur analyzer
- element analyzer
- steel alloy analyzer
- infrared carbon sulfur analyzer
- carbon sulfur analyzer
- total organic carbon analyzer
- carbon sulphur analyzer
- silicone analyzer
- carbon silicone analyzer
- metal analyzer
- bet surface area analyzer
- food safety testing equipment
- food safety tester
- fat analyzer
- carbon analyzer
- diffraction
- infrared analyzer
- content analyzer
- soil tester
- soil ph analyzer
- metal element analyzer
- protein analyzer
- plant leaf meter
- oil moisture sensor
- steel analyzer
- sulfur content analyzer
- soil nutrient tester
- soil fertilizer nutrient tester
- npk soil nutrient tester
- particle size analyzer
Recommended Products
- Industrial M9.03 Dual Flow Monitor | IP65 Front, Multi-Color Backlight, Compatible with Hall Effect & F6.60 Sensors
- FLS M9.02 Flow Monitor – 4" Full-Graphic Display, 4-20mA Output for FLS Sensors (Panel/Wall-Mount)
- FLS F6.30 Paddlewheel Flow Transmitter with 4-20mA/Pulse Output for DN15-DN600 Pipes, IP65 & ±0.75% Linearity
- Ion Contamination Tester Bamtone Ict4063
- Ion Pollution Tester Bamtone/Ict3020
- Ion Contamination Tester Ict7563
- Desktop Hole Copper Surface Test T70
- Handheld Hole Copper Tester Bamtone T65
- Industrial Epoxy-Body FIP C150-200 Conductivity Probe for Chemical/Water Treatment, 7Bar Pressure & Pt100 Temperature Compensation
- High-Precision FIP C150-200 Graphite/Platinum Conductivity Sensor with 0.1-10 Cell Constants, ISO 9001 & CE Certified
- Corrosion-Resistant FIP C100-300 Conductivity Sensor (PP/SS Body) for Ultrapure Water & Wastewater Monitoring
- Multi-Application FIP C100-300 Conductivity Transmitter with Pt1000, Compatible with PLC/DCS Systems
Find Similar Products By Category
- Instruments & Meters > Analysis Instrument > Other Analysis Instruments
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
GoldAPP Instruments
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile