Home > Products > True Density Analyzer > helium pycnometer density analyzer supplier
helium pycnometer density analyzer supplier
- T/T L/C D/P D/A
- 7 days
You May Like
Product Details
Brand Name | Gold APP Instruments | Place of Origin | China | |
Model Number | G-DenPyc 2900 |
Product Description
G-DenPyc 2900 gas pycnometer true density analyzer parameters
Analysis Method: Volume displacement method/gas expansion principle
Versatility: true (also terms as real, absolute, apparent or skeletal) density analysis, rigid foam materials’ percentage of open/closed spaces analysis
Experimental Pressure: external vacuum pump is available, can adopt negative pressure (0-1Bar) or positive pressure (1-2Bar) two modes to analysis
Accuracy: accuracy ±0.02%, repeatability ±0.01%, resolution can reach 0.0001 g/cc
Sample Ports: three samples analysis ports
Sample Container: provide 3ml, 10ml, 15ml and 70ml standard containers, also can customize any volume containers from 1-500ml.
Pressure Accuracy: imported high-precision pressure transducer, accuracy can reach 0.05% F.S., stability 0.025% F.S.
Adsorbate Gas: high purity Helium or air or Nitrogen
G-DenPyc 2900 gas pycnometer true density analyzer features
Data Reduction: high-precision PρT gas density calculation model eliminates measurement errors caused by non-ideality gas state, can increase analysis accuracy
Thermostatic System: analysis modules designed with thermostatic system can control temperature up and down easily, also hold modules stay at the best temperature(25 C) which can restrain transducer reading’s temperature drift and keep system temperature uniformity; System can maintain temperature at a fixed value for some fixed-temperature-required samples
Control System: programmable logic controller (PLC) system obtains high integration and strong anti-interference, software operated fully automated analysis enables freely choose of multi measurement modes
Analysis Management: programmable built-in system, touch screen, USB type external keyboard and mouse, operated by connecting to computer is available
Manifolds System: patented V-Sorb monolithic manifolds system can improve sealing performance and reduce dead space largely, enhance system temperature’s uniformity and anti-interference ability, all lead to a high accuracy and repeatability data
Splash-proof Measures: installed with a detachable filter in sample cell’s bottom, can prevent samples be suctioned into manifolds; inputting gas from bottom of cavity can avoid samples splash and software controlled H-Sorb two-stage-stepping mode further ends splash happening
Sample Container: Exclusive G-DenPyc filling technology supports to choose different volumetric aluminum blocks to fill cell instead change other sizes cells according to samples’ volume, this innovative method realizes minimal free space in cells and improve experiment accuracy
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Contact Us
- Gold APP Instruments Corporation China
- Contact nameGoldAPP Instruments Chat Now
- Phone86-10-82132122
- AddressFloor 6th, Tianli Building, No. 56th, Zhichun Rd., Haidian Dist, Beijing 100098, Liaocheng, Shandong
Product Categories
New Products
-
Langmuir surface area analyzer by static volumetric method
-
Langmuir surface area analyzer
-
BET specific surface area analyzer
-
high pressure gas sorption analyzer
-
gas pycnometer helium true density analyser by gas displacement principle
-
high pressure gas adsorption analyser by volumetric principle
-
surface area and volume measurement analyser for nanomaterials
-
helium pycnometry true density analyzer
-
high pressure volumetric equipment for hydrogen storage materials analysis
-
surface area and volume measurement analyser for active carbon
-
gas pycnometer density | gas pycnometer definition | automatic gas displacement pycnometer
-
gas expansion pycnometer | automated gas expansion pycnometer | gas pycnometer formula | helium gas pycnometer
-
gas sorption analysis | gas sorption analyser | gas sorption theory
-
gas adsorption | gas adsorption isotherm | gas adsorption theory | gas adsorption porosimetry
-
pressure composition diagram data analyzer
-
pressure composition temperature isotherm equipment supplier
-
pycnometer density testing equipment
-
helium pycnometer, helium pycnometer price
Popular Searches
- alcohol tester
- alcohol breath tester
- alcohol tester breathalyzer
- alcohol detector
- breathalyser
- breath tester
- alcohol breathalyzer mouthpiece
- alcohol analyzer
- breath alcohol tester
- alcohol content tester
- keychain breath alcohol tester
- alcohol breathalyzer tester
- alcohol breathalyzer
- gas detector
- breathalyzer
- gas analyzer
- oxygen analyzer
- nitrogen analyzer
- carbon dioxide analyzer
- carbon monoxide analyzer
- carbon dioxide meter
- analyzer co2 meter
- concentration analyzer
- concentration controller
- gas instrument
- o2 analyzer
- o2 tester
- oxygen instrument
- gas detector analyzer
- gas purity analyzer
Recommended Products
- K6050AP Hydrogen Purity and Purge Gas Analyser
- K1650 hydrogen purity and purge gas Analyser
- 2025 KEONE Ultimate Wearable Gas Detector
- 2025 Wrist-Mounted Multi-Gas Detector
- Portable Biomethane Analyzer Gasboard-3200L
- Rexroth Pumps
- Siemens Gas Analyzers
- ABB laser gas analyzers
- ABB Gas Chromatograph Analyzers
- Endress+Hauser Gas Analyzers
- SICK Gas Analyzers
- Continuous Emissions Monitoring System for Marine Exhaust Gas Gasboard-9085
Find Similar Products By Category
- Instruments & Meters > Analysis Instrument > Gas Analyzer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
GoldAPP Instruments
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile