Brand Name | Gold APP Instruments | Place of Origin | China | |
Model Number | V-Sorb 2800S |
Product Description
V-Sorb 2800S BET surface area analyzer parameters
Analysis Method: static volumetric nitrogen adsorption principle
Versatility: Adsorption and desorption isotherms, Single and multi-point BET (Brunauer-Emmett-Teller) surface area, Average particle diameter estimation, t-plot external surface area, True density analysis, Langmuir surface area, carbon black (STSA-Statistical thickness surface area), adsorption constant C.
Measuring Ranges: 0.01 m2/g (by nitrogen)/ 0.0005m2/g (by krypton) to no known upper limit
Accuracy: repeatability errors ≤1%
Vacuum System: V-Sorb unique monolithic manifolds and solenoid valve control system, greatly reduce the dead volume; improve the adsorbate micro-change sensitivity; enhance pore size distribution analysis resolution; decrease connecting points; strengthen sealing performance and prolonged instrument life
Coolant Level Prober: V-Sorb original coolant level control system with temperature probe, ensure the coolant level unchanged when compares with sample cells in the whole analysis process, completely eliminate the analysis errors caused by dead volume change
Sample Treatment: the whole treatment procedures are controlled by dedicated software, as well with a start time preset function which can realize unattended operation at night
Control System: programmable solenoid valve system with high integration and strong anti-interference ability, enhance instrument stability and life
Sample Ports: two samples analyzing and two samples degassing concurrently
Pressure Measurement: imported sectional measuring dual pressure transducer, notably improve the measuring accuracy at low P/Po point, 0-1000Torr (0-133Kpa), 0-10Torr (0-1.33Kpa)
Transducer Accuracy: imported silicon thin film pressure transducer, accuracy can reach 0.1% of real reading, better than 0.1% of F.S.(full-scale), far accurate than Pirani resistance vacuum gauge(general error is 10%-15%)
Partial Pressure: P/Po controllable accuracy range is 5x10-6-0.998
Ultimate Vacuum: 4x10-2Pa (3x10-4 Torr)
Vacuum Pump: built-in bipolar vacuum pump controlled by patented software which can auto control pump’s start/stop
15. Sample Types: powders, nanoparticle, fiber, flakes and other materials
Adsorbate Gas: high purity nitrogen (≥99.999%), Ar, Kr, CO, CO2, C4H10 etc. non-corrosive gases are optional
Data Acquisition: high-precision and high integration data acquisition modules, minimal error, strong anti-interference ability
Data Reduction: Windows?-based independent developed Gold APP Instruments softwareTM, perfect versatility, produced full featured and multi-model reports
Our policy of continuous development may cause the information and specifications contained herein to change without notice or liability.
Contact Us
- Gold APP Instruments Corporation China
- Contact nameGoldAPP Instruments Chat Now
- Phone86-10-82132122
- AddressFloor 6th, Tianli Building, No. 56th, Zhichun Rd., Haidian Dist, Beijing 100098, Liaocheng, Shandong
Product Categories
New Products
-
surface area and pore size analyzer
-
static volumetric principle to determine surface area
-
BJH pore size distribution measurement apparatus
-
Langmuir surface area analyzer by static volumetric method
-
Langmuir surface area analyzer
-
BET specific surface area analyzer
-
high pressure gas sorption analyzer
-
gas pycnometer helium true density analyser by gas displacement principle
-
high pressure gas adsorption analyser by volumetric principle
-
surface area and volume measurement analyser for nanomaterials
-
helium pycnometry true density analyzer
-
high pressure volumetric equipment for hydrogen storage materials analysis
-
surface area and volume measurement analyser for active carbon
-
gas pycnometer density | gas pycnometer definition | automatic gas displacement pycnometer
-
gas expansion pycnometer | automated gas expansion pycnometer | gas pycnometer formula | helium gas pycnometer
-
gas sorption analysis | gas sorption analyser | gas sorption theory
-
gas adsorption | gas adsorption isotherm | gas adsorption theory | gas adsorption porosimetry
-
pressure composition diagram data analyzer
-
pressure composition temperature isotherm equipment supplier
-
pycnometer density testing equipment
-
helium pycnometer, helium pycnometer price
-
helium pycnometer density, helium pycnometer manual
-
helium pycnometer astm, helium pycnometer calculation
-
volumetric co2 analyzer, volumetric adsorption analyzer
Recommended Products
- Honeywell eZtrend? GR Advanced Graphic Recorder agent
- Honeywell DR4300 Circular Chart Recorder agent
- Honeywell DR45AR Truline? Circular Chart Relay Expansion Recorder agent
- Lora Wireless CO2 Sensor
- TOC offline analyzer
- TOC analyzer online analysis
- TOC analyzer TA-200
- TOC analyzer TA-5.0
- TOC analyzer online test
- TOC analyzer offline test
- TOC analyzer
- Qualified HST CS Series Iron ore carbon sulfur analyzer
Find Similar Products By Category
- Instruments & Meters > Analysis Instrument > Element Analyzer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
GoldAPP Instruments
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile