Home > Products > HV Power Factor Correction System > High voltage automatic reactive power compensation device
High voltage automatic reactive power compensation device
- NINGBO or SHANGHAI
- T/T
You May Like
Product Details
Place of Origin | Zhejiang, China | Brand Name | JKCN | |
Model Number | TBB0.4(Outdoor Type) |
Product Description
Specifications
High voltage automatic reactive power compensation deviceis saving energy device for end user
Application
The shunt capacitor is suitable for the power system of power frequency (50 or 60Hz), to increase the power factor, reduce line loss,improve voltage quality.
Main Technical Parameter
1. The relative error between capacitance and rating shall not exceed -5%~+5% or capacitor unit.
2. For the three-phase capacitor, the ratio of maxi and minimum capacitances between any two phase terminals shall not exceed 1.08.
3. For the full film capacitor, Tangent of capacitor loss angle shall not exceed 0.0005, for the film and paper mixed capacitor, it shall not exceed 0.0012
4. Each capacitor shall withstand alternating U = 2.15U or DC voltage Ut = 4.3U voltage between terminals, test duration 10s, it shall have no break t N n own and flashover.
5. AC voltage test between terminal and shell: all capacitors whose all terminals insulated from outer shell shall comply with the requirement of clause 18.1 in the standard of GB/711024.1-2010: during test, no breakdown and flashover shall happen.
6. Power frequency steady over-voltage and its running time of capacitor and the elements shall comply with sheet 2. In order to extend the working life,the capacitor shall run under voltage not over ratings.
7. The capacitor is allowed to work under not over 1.3I steady over-current for long time which caused by rising voltage and high harmonics, for the capacitor with maxi positive deviation, the permissible current up to 1.37I . In order to extend the service life, the capacitor shall work under rated current. n
8. The capacitor can withstand the surge up to 100 times of rated current, the times of such surging impact shall not exceed 1000, among these, some of surging impact shall happen at the capacitor inside temperature not more than 0°C.
9. The capacitor with built-in resistance, can discharge automatically and the voltage between terminals shall fall down to 75V or lower within 10 minutes.
10. High voltage shunt capacitor (more than 1000V) complies with national standard GB/T11024.1-2010 (eqv. IEC871-1)
Contact Us
- Zhejiang Jiukang Electric Co., Ltd.
- Contact namemarco qu Chat Now
- Phone86-577-67398302 67398303 67
- AddressWuniu Town Industrial Zone, Wenzhou, Zhejiang
Product Categories
New Products
-
New Float switch/fluid level controller
-
Water level Controller
-
Float Switch Level Float Controller
-
Liquid Switch/Float Switch/Water Level Regulator
-
Automatic water level sensor
-
Float sensors for water level mesuring
-
water level float switch/liquid lelvel sensor for liquid controlling
-
electronic lelvel sensor
-
lelvel sensor
-
float type level switches
-
float switch for water pump
-
Cable Float Switch Liquid Level Control
Popular Searches
- switchgear
- distribution board
- Zinc Oxide Varistor
- Lightning Rod
- spd
- surge protector
- surge arrester
- surge suppressor
- power surge
- lightning arrester
- zinc oxide lightning arresters
- Lightning Arrester Rod
- Lightning Rod Tower
- Polymer Surge Arrester
- electrical switchgear
- zinc oxide varistors
- power distribution unit
- pdu
- Power Supply Device
- distribution cabinet
- Metal Oxide Varistor
- cabinet pdu
- rack pdu
- power distribution cabinet
- Power Resistor
- High Voltage Resistor
- switchboard
- hv switchgear
- gas insulated switchgear
- ring main unit
Recommended Products
- SF6 Fully InsulatedRing Main Unit
- Combined Busbar Hydraulic Turret-Type 3 in 1 Processing Machine with CE certified (EU standards) & ISO 9001
- Double Ended CNC Busbar Trunking Bending Machine
- Automatic Servo Turret CNC Three-table Busbar Processing Machine
- Open-Type Manual Control Hydraulic Turret-Type 3 in 1 Busbar Processing Machine-Heavy-Duty
- Open-Type Hydraulic Turret-Type 3 in 1 CNC busbar processing machine/303A,303B,303/503C,303/503D
- CNC Double Table 3 in 1 Turret-Type Busbar Processing Machine close type ISO 9001 BT-C303C/BT-C503C/BT-C803C
- Manual Control Hydraulic Turret-Type 3 in 1 Busbar processing Machine-Closed Type BT-M303C/BT-M503C
- Wholesales NSPV MLJ-01 connector Solar PV Panel Mini Junction Box
- 17.5 KV Full-enclosed Outdoor Epoxy Resin Casting and Double Pole Insulated Voltage Transformer
- JDZX10-10 Single Phase Indoor Fully Insulated Resin Integrated MV&HV Transformer 10kv High Voltage JDZ10-10A/B
- JDZ10 Sheep Angle Enclosed 10kV Indoor High-voltage Transformer
Find Similar Products By Category
- Electrical & Electronics > Power Supply & Distribution > Power Distribution Cabinet & Box
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
marco qu
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile