Home > Products > Overhead type > Overhead line short-circuit and ground fault indicator
Overhead line short-circuit and ground fault indicator
- Zhuhai/Guangzhou/Shenzhen
You May Like
Product Details
Place of Origin | Guangdong, China | Brand Name | Gene Cosmos | |
Model Number | CSM-AK3 |
Product Description
1 Summarize
Day Night
CSM-AK3 is used in 6-35 KV power transmission and distribution line, used for indicating the position of fault current section including the short-circuit fault and ground-fault. Furthermore, it can choose a way to indicate red flag indication or led indication according to day or night. When the fault happens, the patrol personnel can locate the fault section and find out the fault point rapidly depends on the red alarm display of the fault indicator. It can greatly improve the work efficiency and shorten the time of power outage. It makes the transmission reliable.
2 Feature
Fault indication | When the line is normal, the flag indication area is white. When the fault happens, the flag indication area is red.
|
Working | It can be mounted under live conditions directly without maintenance.
|
Good adaptation | Automatic judgment, it can show the indication as red flag at day and led flash at night. In this way it can improve efficiency.
|
Strong anti-interference | The signal is not affected by the line, magnetizing inrush current, high order harmonics, current fluctuations, especially the ring of the cable distribution capacitor.
|
Reset automatically | The indicator can reset automatically after the fault indication with the impact of the recovery power transmission.
|
Be mounted under live conditions | It can be mounted under live conditions with the help of an adapter and a hot stick.
|
3 Technical parameters
Applicable voltage level: | U≥6KV | Applicable wire current: | I≤1000A |
Action response time: | 0.06S≤T≤3S | static power consumption | ≤10μw |
Reset time: | 12,24hours optional | Operation: | ≥3000times |
Ambient Temperature: | -40℃≤T≤+75℃ | Weight | 460g |
Applicable conductor wire diameter: | 25mm2≤d≤400mm2 |
4 Applied range
- Ø Install the indicators at the middle of a long line or the entrance of branch: they can indicate the fault section and fault branch.
- Ø Install the indicators at the exit of substation: they can judge if the fault happens indoor or outdoor.
- Ø Install the indicators at the high voltageincoming line of the user’s distribution transformer: they can judge if the fault is caused by the user.
- Ø Install the indicators at the junction of the cable and overhead line, they can distinguish if the fault is located at the cable side.
Contact Us
- Zhuhai Gene Cosmos Electric Technology Co., Ltd.
- Contact nameCarin Fung Chat Now
- Phone0086-0756-3639183
- Address3/F, Building E, No.18 Technology Road 7 High-tech Zone, Zhuhai, Guangdong
Product Categories
New Products | Overhead type |
Popular Searches
- switchgear
- distribution board
- Zinc Oxide Varistor
- Lightning Rod
- spd
- surge protector
- surge arrester
- surge suppressor
- power surge
- lightning arrester
- zinc oxide lightning arresters
- Lightning Arrester Rod
- Lightning Rod Tower
- Polymer Surge Arrester
- electrical switchgear
- zinc oxide varistors
- power distribution unit
- pdu
- Power Supply Device
- distribution cabinet
- Metal Oxide Varistor
- cabinet pdu
- rack pdu
- power distribution cabinet
- Power Resistor
- High Voltage Resistor
- switchboard
- hv switchgear
- gas insulated switchgear
- ring main unit
Recommended Products
- Polyester Enclosure Fiberglass box IP65 waterproof GRP Cabinet distribution box
- AC LV Withdrawable Switchgear
- SF6 Fully Insulated Ring Main Unit
- Combined Busbar Hydraulic Turret-Type 3 in 1 Processing Machine with CE certified (EU standards) & ISO 9001
- Double Ended CNC Busbar Trunking Bending Machine
- Automatic Servo Turret CNC Three-table Busbar Processing Machine
- Open-Type Manual Control Hydraulic Turret-Type 3 in 1 Busbar Processing Machine-Heavy-Duty
- Open-Type Hydraulic Turret-Type 3 in 1 CNC busbar processing machine/303A,303B,303/503C,303/503D
- CNC Double Table 3 in 1 Turret-Type Busbar Processing Machine close type ISO 9001 BT-C303C/BT-C503C/BT-C803C
- Manual Control Hydraulic Turret-Type 3 in 1 Busbar processing Machine-Closed Type BT-M303C/BT-M503C
- Wholesales NSPV MLJ-01 connector Solar PV Panel Mini Junction Box
- 17.5 KV Full-enclosed Outdoor Epoxy Resin Casting and Double Pole Insulated Voltage Transformer
Find Similar Products By Category
- Electrical & Electronics > Power Supply & Distribution > Power Distribution Cabinet & Box
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Carin Fung
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile