We require design and supply of steam boiler systems for LPG processing with the following specifications:
1. Storage Bullets: 50 m3 mounded design, ASME VIII Div.1 compliant, 17-20 barg pressure rating, dual PRVs with changeover system, complete with level monitoring and safety features.
2. Vaporizers: Water-bath type with 400 kg/h capacity base configuration or 200 kg/h modular setup, including safety relief systems and temperature controls.
3. Full compliance with ASME B31.3 piping standards and NFPA 58 safety requirements for entire system integration.
All components must include proper pressure regulation stages from 6-8 barg down to 0.1-0.3 bar burner supply.
                                            Yemen
                                        Posted at: 2025-09-23 15:07:12R******Email:****** - 
                        
Inquiry about GRP Cartridge Filter Housings for Seawater RO Plants
Scope: Seawater filtration in RO plants (Max TDS 41,000 mg/L, a?¤30?°C, pH 4a??9). Technical Specifications: Flow Capacity: a?¥475m3/hr at 6 bar. Pressure Drop: a?¤2bar (inlet to outlet). Filter Elements: Minimum 140 per housing (40", double open-ended, individual replacement). Materials: Housing: Food-grade certified FRP/GRP (defect-free). Wetted Parts: Stainless Steel (PREN a?¥42). Design: RO Plant 1: EN1092 DN300 PN10 flanges. RO Plant 2: ASME B16.5 12" Class 150 flanges. Max Height: 3,000 mm (including davit arm).
                                            United States
                                        Posted at: 2025-05-12 21:50:05
                                            ******Email:******