Home > Products > GE > GE Multilin 369-HI-R-M-0-0-0-E Motor Management Relay – Protection, Monitoring, and Control for Critical Motors
GE Multilin 369-HI-R-M-0-0-0-E Motor Management Relay – Protection, Monitoring, and Control for Critical Motors
- T/T L/C PayPal D/P Western Union Other
You May Like
-
EMERSON 38B5786X132 – OEM Mounting/Linkage Assembly for Valve Positioners and Actuators
-
ABB 3BHB003688R0001 IGCT Module – High?power switching element for medium?voltage drives and converters
-
ABB 3BHB004027R0101 IGCT Gate Unit – Reliable drive control for medium-voltage power stacks
-
ABB 3BHE042816R0101 – Control Board Module for Industrial Drive and Power Electronics Systems
-
ABB 3BSE017235R1 – S800 I/O/AC 800M Accessory for Reliable I/O Expansion
-
SCHNEIDER 490NRP25300 – Modicon fiber network repeater for extending and securing control networks
Product Description
The GE Multilin 369 series is a workhorse motor management relay designed to protect and optimize medium and large induction motors in harsh industrial environments. The 369-HI-R-M-0-0-0-E build typically combines robust motor protection (thermal, jam/stall, ground fault) with temperature monitoring and enhanced metering. From my experience, it fits well in MCC buckets and switchgear retrofits where reliability, clear diagnostics, and straightforward wiring are priorities.
You might notice that sites choose the 369 for its stable thermal model and its flexible I/O. It seems to deliver a good balance between protection depth and day?to?day usability, especially when the team wants Modbus visibility in DCS/SCADA without adding extra hardware.
Key FeaturesComprehensive motor protection – Overload (thermal model), jam/stall, undercurrent, phase loss, phase unbalance, and ground fault to guard against common process and electrical faults.
Integrated temperature monitoring – The “R” option in this build appears to include RTD inputs for stator and bearing temperature; typically supports multiple Pt100 channels for early warning.
Advanced metering – The “M” option provides true RMS metering of currents and key electrical values, reducing the need for a separate feeder meter in many cases.
Flexible current inputs – Works with standard 1 A or 5 A secondary CTs; a separate ground CT can be used for sensitive ground fault protection.
Event records and diagnostics – Time?stamped trips/alarms and trending help maintenance teams pinpoint root causes faster.
SCADA connectivity – RS?485 Modbus RTU is commonly supported for remote monitoring, control, and data collection.
Rugged, plant-ready design – Built for panel or switchgear door mounting with a clear front interface for local operators.
Start control and permissives – Digital inputs/outputs allow permissive logic, interlocks, and start inhibit based on thermal capacity or temperature.
This relay is typically deployed on conveyor drives, pumps, fans, compressors, and mixers where both mechanical and electrical stresses can appear without much warning. In many cases, plants standardize on the 369 for their process?critical motor feeders to keep trip logic and SCADA tags consistent across units.
Mining and aggregates – Crushers, conveyors, slurry pumps with jam/stall trip logic to prevent mechanical damage.
Oil & gas – Produced water pumps, cooling fans, and export pumps with RTD?based thermal restraint.
Water & wastewater – Aeration blowers and high?service pumps needing ground fault sensitivity and starts?per?hour limits.
Pulp & paper – Refiners and vacuum pumps, where unbalance and overload events are common during grade changes.
Metals and cement – High?inertia drives benefiting from start supervision and thermal capacity tracking.
Power & utilities – Balance?of?plant motors with consistent Modbus telemetry back to DCS.
Reliable protection logic – The thermal model and jam/stall functions reduce nuisance trips while still reacting fast to real faults.
Retrofit?friendly – Works with existing 1 A/5 A CTs and standard ground CTs; panel cutouts are straightforward in most MCC doors.
Lower total installed cost – With the “M” metering option, many users drop a separate feeder meter and wiring.
Maintenance visibility – Event logs and RTD trends help teams troubleshoot without dragging portable instruments to site.
Lifecycle support – Widely used platform with stable firmware and broad field experience; spares and know?how are easy to source.
Mounting – Panel/door mount on a clean, vibration?controlled surface; follow the 369 cutout drawing and maintain clearance for terminal access.
Power & grounding – Use a dedicated control power circuit with proper fusing; bond the relay ground to the panel ground bar to minimize noise.
CT/VT wiring – Observe CT polarity; never open?circuit a live secondary. For sensitive ground fault, use a window (core?balance) CT around phase conductors.
RTD and I/O – Route RTD leads separately from power; use shielded twisted pairs and land shields at one end to reduce interference.
Ventilation – Keep ambient within spec; provide cabinet ventilation if mounting alongside heat?generating drives or soft starters.
Configuration – Commission with conservative protection pickups, then tune using event logs and thermal capacity feedback after a few weeks of operation.
Routine care – Annually verify trip circuits, clean terminals, back up settings files, and update firmware when validated for your site standard.
Spare strategy – For critical lines, many sites hold 1:10 spares, plus one ground CT and a set of pre?terminated RTD harnesses.
Core?balance ground CT sized to your feeder cables for sensitive earth?fault detection.
Pt100 RTDs for stator slots and bearing housings; three?wire configuration is typical for accuracy.
RS?485 to Ethernet gateway (if your SCADA is Ethernet?only) with Modbus pass?through.
Miniature control power breaker and surge suppressors for the control supply circuit.
CE compliant for EMC and Low Voltage directives (model dependent and region specific).
UL/cUL listing for industrial control equipment is commonly available on 369 series builds.
RoHS alignment where applicable; consult the exact build code for material declaration.
Manufacturer’s warranty: typically 2 years from shipment when installed per the manual.
Company Profile

Xiamen Xiongba E-commerce Co., Ltd. is a control system component company, located in Siming District, Xiamen, a beautiful coastal city. Xiamen Xiongba E-commerce Co., Ltd. is one of the largest control system components in China, focusing on industrial automation PLC and DCS modules. Our company has 20 years of experience in the field of automatic control. We specialize in supplying world-renowned brands: Allen Bradley, ABB, General Electric, Triconex, Honeywell, Bentley Nevada, Schneider, Hima, and even some...
Contact Us
- Xiamen Xiongba e-commerce Co., LTD
- Contact nameLynn Chat Now
- Phone86-86-18059884797
- AddressRoom 2009, Chuangxiang Center, No. 1733, Luling Road, Siming District, Xiamen xmxblynn@163.com, Xiamen, Fujian
Product Categories
New Products
-
SCHNEIDER 490NRP25400 – Modbus Plus Network Repeater for Segment Extension and Isolation
-
HONEYWELL 51196655-100 – Legacy DCS Board Assembly for TPS/TDC Systems
-
HONEYWELL 51304644-175 – OEM Control System Module for TPS/Experion Maintenance and Uptime
-
HIMA 5203 – Interface Module for Integrating Safety Controllers with Plant Networks
-
GE 531X303MCPARG1 AC Power Board – Stable control power for legacy GE drive systems
-
GE 531X303MCPBBG1 Main Control Power Board – Stable AC-to-DC control power for GE drive and excitation systems
-
GE 531X303MCPBDG1 – MCPB Control Board for AC/DC Drive Platforms
-
GE 531X304IBDARG1 PC Basic Driver Card – Reliable signal interface for legacy GE drive platforms
-
GE 531X304IBDASG1 Inverter Bridge Driver Card – Reliable gate drive and protection for GE industrial drives
-
GE 531X305NTBANG1 Terminal Board – Reliable Field I/O Termination for GE Drive Systems
-
GE 531X305NTBAPG1 – NTBA Terminal Board for Field I/O Termination in Legacy GE Drives and Control Systems
-
GE 531X307LTBAHG1 LAN Terminal Board – Reliable field I/O and LAN termination for legacy GE drive systems
-
GE 531X307LTBAJG1 LAN Terminal Board – Reliable field wiring interface for GE drive networks
-
Emerson 5X00034G01 – Reliable Ovation DCS I/O Module for Plant Automation
-
Emerson 5X00058G01 – HART Analog Input Module for Ovation DCS
-
EMERSON 5X00109G01 HART Analog Input Module – Smart 4–20 mA acquisition with HART diagnostics
-
EMERSON 5X00109G02 Analog Input Module – Stable, accurate process signal acquisition for Ovation DCS
-
EMERSON 5X00119G01 – 8?Channel RTD Input Module for Precision Temperature Monitoring in Ovation Systems
-
EMERSON 5X00226G01 Relay Output Module – Reliable dry-contact switching for Ovation DCS
-
EMERSON 5X00226G02 Solid-State Relay Output Module – Clean, Durable Digital Switching for DCS Applications
-
EMERSON 5X00226G03 – Ovation I/O Module for dependable DCS signal processing and spares coverage
-
EMERSON 5X00241G02 – Ovation I/O Module for Reliable Field Signal Integration
-
Emerson 5X00270G01 Ovation I/O Module – Reliable field signal interface for installed Ovation DCS
-
EMERSON 5X00300G02 – Ovation I/O Module for Stable, Plant?wide Control
Find Similar Products By Category
- Industrial Equipment & Components > Other Equipment & Components

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Lynn
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile