Home > Products > GE > GE 531X305NTBAPG1 – NTBA Terminal Board for Field I/O Termination in Legacy GE Drives And Control Systems
GE 531X305NTBAPG1 – NTBA Terminal Board for Field I/O Termination in Legacy GE Drives And Control Systems
- T/T L/C PayPal D/P Western Union Other
You May Like
-
GE 531X307LTBAHG1 LAN Terminal Board – Reliable Field I/O And LAN Termination for Legacy GE Drive Systems
-
GE 531X307LTBAJG1 LAN Terminal Board – Reliable Field Wiring Interface for GE Drive Networks
-
Emerson 5X00034G01 – Reliable Ovation DCS I/O Module for Plant Automation
-
Emerson 5X00058G01 – HART Analog Input Module for Ovation DCS
-
EMERSON 5X00109G01 HART Analog Input Module – Smart 4–20 mA Acquisition With HART Diagnostics
-
EMERSON 5X00109G02 Analog Input Module – Stable, Accurate Process Signal Acquisition for Ovation DCS
Product Description
The GE 531X305NTBAPG1 (often referenced as an NTBA terminal board) is a field I/O termination platform used in GE legacy drive and control packages. In practical terms, it serves as the landing point between cabinet wiring and the controller, handling mixed discrete and analog signals with basic filtering and protection. It’s typically chosen to keep legacy GE systems running reliably, especially where a drop-in electrical fit is needed to minimize downtime.
Field I/O termination – Screw terminals provide a tidy, serviceable interface for cabinet wiring to the control electronics.
Mixed-signal handling – Typically accommodates 24 VDC digital inputs/outputs and low-level analog signals (such as ±10 V or 4–20 mA), depending on system configuration.
Onboard protection and conditioning – You might notice RC filtering, surge suppression, and opto-isolation in many builds, which helps reduce noise and nuisance trips.
Ribbon/edge interconnects – From my experience, the board mates to the controller via ribbon cable headers or edge connectors common to the GE 531X/DS200 family.
Service-friendly layout – Clear terminal labeling and separation of analog vs. digital points make field checks and troubleshooting faster.
Legacy system continuity – Suited as a replacement in older GE drive and excitation cabinets where keeping the existing wiring harness is key.
This board shows up in mature GE platforms used across heavy industry. You’ll typically see it in:
Steel and metals processing lines where mixed analog/digital I/O needs robust termination in noisy environments.
Pulp & paper mills, especially on legacy GE drives still running reliably after many years.
Mining and cement facilities where downtime avoidance is more valuable than a complete controls redesign.
Power generation auxiliaries and excitation systems that favor drop-in maintenance parts over platform changes.
General industrial retrofits when maintaining existing harnesses and terminations saves commissioning time.
Reduced downtime – It seems to be a straightforward electrical fit in many GE legacy cabinets, so swap-outs are quicker.
Compatibility – The NTBA layout is well known in the 531X/DS200 family; still, verifying pin-out and revision against your controller is the safe move.
Lower retrofit risk – Keeps existing field wiring and signal scaling intact in most cases, avoiding a snowball of rewiring.
Serviceability – Clear terminals and accessible test points help maintenance teams diagnose issues fast.
Lifecycle support – A practical option to extend the usable life of installed GE assets while planning long-term upgrades.
Cabinet & mounting – Install in a clean, ventilated control cabinet. Use the original standoff pattern; maintain adequate clearance around terminal strips.
Wiring practices – Separate analog from high-voltage cabling, shield analog pairs, and bond shields at the recommended single point to cut down noise.
Terminal torque – Re-torque screw terminals after initial thermal cycles; loose terminations are a common, preventable fault.
ESD handling – Handle the board with ESD precautions; store in antistatic packaging when off the machine.
Jumper/settings – Some NTB variants include jumpers or configurable ranges. Confirm positions match your controller’s I/O expectations before energizing.
Routine checks – Inspect for discoloration, damaged traces, or buildup of dust. Clean with approved electronics cleaner; avoid moisture.
A maintenance lead at a paper plant told us they swapped a worn NTBA for the 531X305NTBAPG1 during a 4?hour window—no rework on harnesses, and their analog scaling lined up right away. That’s fairly typical when the revision matches the installed controller.
Manufacturing quality – Produced under GE’s quality system (commonly aligned with ISO 9001 practices for industrial electronics).
CE/UL context – Compliance is typically tied to the complete drive/control assembly; this board is intended for use within that certified system.
RoHS – Depending on build date and region, earlier legacy boards may not be RoHS. If that’s a requirement, specify at time of order.
Warranty – Standard limited warranty terms (often 12 months repair/replace) are available; exact coverage can vary by supply channel and condition (new, surplus, or refurbished).
If you’re replacing an existing NTBA, match the model and revision (531X305NTBAPG1) against your installed controller documentation and backplane connector map. When in doubt, share a photo of your current board’s terminal layout and connector labels—we can cross-check compatibility and any required jumper positions before you schedule the changeout.
Company Profile

Xiamen Xiongba E-commerce Co., Ltd. is a control system component company, located in Siming District, Xiamen, a beautiful coastal city. Xiamen Xiongba E-commerce Co., Ltd. is one of the largest control system components in China, focusing on industrial automation PLC and DCS modules. Our company has 20 years of experience in the field of automatic control. We specialize in supplying world-renowned brands: Allen Bradley, ABB, General Electric, Triconex, Honeywell, Bentley Nevada, Schneider, Hima, and even some...
Contact Us
- Xiamen Xiongba E-commerce Co., LTD
- Contact nameLynn Chat Now
- Phone86-86-18059884797
- AddressRoom 2009, Chuangxiang Center, No. 1733, Luling Road, Siming District, Xiamen xmxblynn@163.com, Xiamen, Fujian
Product Categories
New Products
-
EMERSON 5X00119G01 – 8?Channel RTD Input Module for Precision Temperature Monitoring in Ovation Systems
-
EMERSON 5X00226G01 Relay Output Module – Reliable Dry-contact Switching for Ovation DCS
-
EMERSON 5X00226G02 Solid-State Relay Output Module – Clean, Durable Digital Switching for DCS Applications
-
EMERSON 5X00226G03 – Ovation I/O Module for Dependable DCS Signal Processing And Spares Coverage
-
EMERSON 5X00241G02 – Ovation I/O Module for Reliable Field Signal Integration
-
Emerson 5X00270G01 Ovation I/O Module – Reliable Field Signal Interface for Installed Ovation DCS
-
EMERSON 5X00300G02 – Ovation I/O Module for Stable, Plant?wide Control
-
Emerson 5X00321G01 – Ovation DCS Module for Reliable I/O Interface And System Upkeep
-
EMERSON 5X00357G03 Ovation I/O Module – Stable Field Signal Interface for Critical Control
-
EMERSON 5X00419G01 – Ovation DCS Module for Reliable Field I/O Integration And System Maintenance
-
EMERSON 5X00481G01 – Ovation I/O Module for Reliable Field Signal Integration
-
EMERSON 5X00481G04 – Ovation DCS I/O Module for Dependable Plant Signal Interfacing
-
EMERSON 5X00497G01 – Ovation DCS Module for Robust Plant I/O And System Expansion
-
EMERSON 5X00501G01 – Ovation DCS I/O Module for Dependable Field Signal Interfacing
-
EMERSON 5X00583G01 – Ovation DCS I/O Module for Reliable Plant Control And Lifecycle Spares
-
EMERSON 5X00594G01 – Ovation I/O Module for Reliable Plant Control And Fast Spares Replacement
-
National Instruments SCXI-1124 – Multi?Channel Analog Output for SCXI Test & Control Racks
-
PROSOFT 6104-WA-PDPM – PROFIBUS DP Master Gateway for Plant-wide Integration
-
GE Multilin 750-P1-G1-S1-HI-A20-G – Feeder Protection Relay for Reliable MV/LV Distribution
-
Rotary Encoder 750-P5-G5-D5-HI-A20-R – Incremental Feedback for Precise Motion Control
-
8101-HI-TX-02 High?Isolation Two?Channel Signal Transmitter for DIN?Rail I/O
-
ABB 83SR04C-E (GJR2390200R1411) – Relay Output Module for Procontrol P14 Systems
-
8521-EB-MT Ethernet–Modbus TCP Gateway for PLC/SCADA Connectivity
-
GE PAC8000 8521-HC-MT – HART Maintenance Access for Remote Field I/O
Find Similar Products By Category
- Industrial Equipment & Components > Other Equipment & Components

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Lynn
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile