Gas Chromatography Analyzer
Product Model: JF0713
Working Conditions
1.1 Operating temperature: 5 ℃ to 40 ℃
1.2 Ambient humidity: 5 % to 95 % in non-operating state and 20 % to 50 % in operating state
1.3 Working voltage: 220 V ± 10 % 50Hz
Column temperature box parameters
2.1 Furnace size: 28×30×18 cm. Can accommodate two 105 m x 0.530 mm internal diameter
capillary columns or two 10 ft glass filled columns (coiled 9 in., 1/4 in. Od) or two 20 ft
stainless steel filled columns (1/8 in. Od) in air heated type volume ≥15 L
Apparent dimensions: 59 x 52 x 51 cm
2.2 Operating temperature range: above Rt +4℃ ~ 450℃
2.3 Programmable temperature rise: 20 stages 21 platforms
2.4 Temperature control accuracy: 0.01℃
2.5 Maximum heating rate can be set: 120℃/min
2.6 Column box cooling (22℃ room temperature) : from 450℃ to 50℃ less than 360s
(optional fast fan)
2.7 Maximum one-time method running time: 999.99min
2.8 Compensation for Runnable column loss (Dual channel)
2.9 Heating area: 6 independent control heating area control
(not including furnace temperature control)
2.10 Maximum operating temperature of auxiliary heating area: 300℃
2.11 Heating area of independent column box can be set
2.12 It has the automatic protection function of column box temperature
Parameters of the injection port
3.1 A maximum of two injection ports can be installed
3.2 It can be used with septum purge packed column injector (PIPP) standard and inert flow
shunt/non-shunt capillary injector (S/SL) cold cylinder injector (COC)
3.3 Packed column injector
3.3.1 Maximum operating temperature 450°C
3.3.2 High precision electronic pressure/flow control
3.3.3 Cylinder pressure setting range: 0 ~ 100psi
3.3.4 Cylinder pressure control setting accuracy: 0.001psi
3.3.5 Total flow setting range: 0 ~ 100 mL/min
3.3.6 Flow setting accuracy: 0.001mL/min
3.3.7 Replacement reducer ADAPTS to 1/4 inch, 1/8 inch filled column, and 0.53/0.32mm capillary
column
3.4 Shunt/Non-Shunt Capillary Column Inlet
3.4.1 Maximum operating temperature 450℃
3.4.2 High precision electronic pressure/flow control
3.4.3 Cylinder pressure setting range: 0 ~ 100psi
3.4.4 Cylinder pressure control setting accuracy: 0.001psi
3.4.5 Total flow setting range: 0 ~ 1000 mL/min (helium) 0 ~ 200 mL/min (nitrogen)
3.4.6 Accuracy of flow setting: 0.001 mL/min
3.4.7 Maximum shunt ratio: 1:7500
3.4.8 Program boost/current: Step 3
3.4.9 Gas control mode: constant pressure, constant flow, programmed rise/fall, programmed
rise/fall
3.5 Cold cylinder Injector (COC)
3.5.1 Maximum operating temperature: 450°C, third stage heating or furnace temperature tracking
3.5.2 Electronically controlled spacer purge flow
3.5.3 Setting range of cylinder pressure: 0 ~ 100psi
3.5.4 Direct injection into the capillary column ensures quantitative sample transfer without thermal
degradation
3.5.5 Direct automatic liquid injection into a 0.53/0.32mm bore column
Detector parameters
4.1 A maximum of two independent temperature control detectors can be installed
4.2 All detectors are included as electronic flow control modules
4.3 Optional detector: FID, TCD, u-ECD, FPD, PDHID, MS
4.4 Hydrogen Flame Ionization Detector (FID)
4.4.1 High precision electronic flow/pressure control
4.4.2 Fit packed column and capillary column
4.4.3 Maximum operating temperature 450°C
4.4.4 Detection limit ≤1.5pg C/s (n-cetane)
4.4.5 Baseline Drift (30min) ≤3×10-13A
4.4.6 Baseline noise ≤ 5× 10-14A
4.4.7 Dynamic linear range ≥107
4.4.8 Data collection frequency: Maximum 500Hz
4.5 Thermal Conductivity Detector (TCD)
4.5.1 High precision electronic flow/pressure control
4.5.2 Fit packed column and capillary column
4.5.3 Maximum Operating temperature 400°C
4.5.4 Detection limit ≤1500 pg/ml (benzene-toluene)
4.5.5 Sensitivity ≥5000 mV·mL/mg (benzene-toluene)
4.5.6 Baseline Drift (30 min) ≤0.2mV
4.5.7 Baseline noise ≤0.1 mV
4.5.8 Dynamic linear range ≥105
4.5.9 Data collection frequency: Maximum 500Hz
4.5.10 Unique fluid switching design (monofilm microcell), from the start of the switch quickly
reach balance (within 5min), low drift
Injector parameters
5.1 Optional processing capacity: 16 bits, 152 bits
5.2 B76 automatic sampler
5.2.1 Sample number: 16
5.2.2 At most two samples can be loaded at the same time to realize double column sampling
5.2.3 Automatic cleaning function of syringe before and after injection: solvent A and B are
automatically cleaned for 0 ~ 15 times
5.2.4 Sampling accuracy deviation: <1%
5.2.5 Viscosity delay: 0 ~ 7 s
5.2.6 Sample size range: 2%-50% (depending on syringe size, minimum 0.02ul)
5.2.7 Residence time before and after injection: no more than 1min
5.2.8 Software Anti-control
5.3 B152 automatic sampler with 3D guide rail
5.3.1 Sample number: 152
5.3.2 XYZ sampling and injection mode, which does not occupy the sampling port, can realize the
sampling at the front and back ports
5.3.3 Adjustable injection size: Drop down option 2% 10% 20% 30% 40% 50% or custom input,
minimum 0.01ul (related to injection needle)
5.3.4 Injection needle Specifications: 1ul, 5ul, 10ul, 100ul, 500 ul
5.3.5 Sample bottle specification: 2ml solvent bottle specification: 10ml waste liquid bottle
specification: 10ml
5.3.6 Sampling mode: conventional liquid sampling, air-tight sampling (liquid + air),
sandwich sampling (sample + air + solvent)
5.3.7 Sampling port: forward sampling port, rear sampling port, front + rear sampling port
5.3.8 Sampling speed: 0-7 grades
5.3.9 Injection speed: fast/slow speed
5.3.10 Residence time before and after injection: 0-1min
5.3.11 Software reverse control automatic sampler
Chromatographic workstation
6.1 Windows 7/10 32-bit Graphical User Interface (including User assistant and other functions)
6.2 Can quickly set the parameters of the front and rear inlet, the front and rear detector, the
temperature procedure of column temperature chamber, column conditions and valve events
6.3 It has powerful application functions such as double-click automatic identification of
chromatographic peak retention time, automatic sampler sequence collection for multigraph comparison and repeatability analysis, automatic integral correction and output report
6.4 Peak integration processing function, qualitative function (supporting multiple relative retention time, grouping), quantitative function (area percentage method, correction area percentage method, internal standard method, external standard method), calibration points and levels, manual production of working curve function, column performance calculation, data comparison function
6.5 GC automatic stop/automatic start, system confirmation (GC self-diagnosis), function, status recording function
6.6 Chinese and English are optional
7. Data communication: Advanced Ethernet (LAN), remote start/finish (wireless interconnection)
8 kinds of auxiliary electronic flow control modules are optional
8.1 Single-channel gas flow Control Module (Pressure control mode)
8.2 Single-channel Auxiliary Pressure Control Module (Pressure Control Mode)
8.3 Dual-channel Auxiliary Pressure Control Module (Pressure Control Mode)
8.4 Three-channel auxiliary Pressure control Module (Pressure control mode)
9. Instrument control panel: touch screen
Contact Us
- Hunan Addition Instruments and Apparatus Co., Ltd.
- Contact nameSalinna Chat Now
- Phone86-0731-86865808
- AddressHuangxing Avenue, Changsha, Hunan
Product Categories
Benzene | Crude,F(xiàn)uel oil,Biodiesel | Antifreeze, Brake Fluid Type | Quenching Oil |
Paraffin,Pitch | Natural Gases | Lubricant | Lab Supplies |
Engine Coolants Tester |
New Products
-
ASTM D3336 Automatic Lubricating Greases in Ball Bearings at Elevated Temperatures Tester
-
ASTM D2983 Low Temperature Brookfield Viscosity Tester
-
ASTM D2619 Hydraulic Oil Hydrolysis Stability Tester
-
ASTM D1078 Automatic Benzene Products Distillation Range Tester
-
ASTM D1321 Auto Needle Penetration of Petroleum Waxes Tester
-
ASTM D127 Petroleum Waxes and Oil Grease Drop Melting Point Tester
-
ASTM D87 Auto Melting Point of Wax Tester
-
ASTM D1534 Auto Acid Number in Transformer and Turbine Oils in Service by BTB Method
-
ASTM D5182 FZG Gear Oil Wear Testing Machine
-
ASTM D1551 Sulfur Content of Petroleum Products Tester (Tubular Furnace Method)
-
ASTM D2602 Full Automatic CCS Cold Cranking Simulator Apparent?Viscosity of Engine Oils Tester (16 test units)
-
ASTM D524 Petroleum Ramsbottom Carbon Residue?Tester
-
SY7509 Residues in Liquefied Petroleum Gases Tester
-
Conradson?Carbon?Residue of Petroleum Products Tester
-
ADDITION Petroleum Products Electric Furnace Carbon Residue Tester
-
IS 10512 ADDITION Petroleum Asphalt Wax Content Tester
-
CNOMO D65 5212 ADDITION Metalworking Fluid Anti-Foaming Tester
-
ADDITION Auto Portable Particle Counter Hydraulic Fluid Cleanliness Tester
-
ADDITION Auto Asphalt Rotary Film Oven Rolling Thin Film Oven Test
-
Automatic Quinoline and Toluene Insolubles Non-Toxicity Tester
-
ADDITION Auto Liquid Hydrocarbon Flash Vaporisation Sampler
-
ASTM D665 ISO7120 DIN51585 ADDITION Rust-Preventing Characteristics Tester
-
ADDITION Chemical Stability of Refrigeration Oil Tester
-
ASTM D4290 ADDITION Automotive Wheel Bearing Grease Leakage Tendencies Tester Under Accelerated Conditions
Popular Searches
- Analyzer Gas Chromatograph
- Gas Chromatography Machine
- lab equipment
- analysis instrument
- Gas Analyzer
- testing machine
- lab instrument
- test equipment
- hydrogen generator
- hplc
- Transformer Oil
- hydrogen gas generator
- Air Generator
- gas chromatograph
- liquid chromatography
- chromatography system
- gc
- chromatograph
- mass spectrometer
- Solvent Gas
- Chromatography Analyzer
- Chromatography Instrument
- Chromatography Machine
- silica gel
- medical equipment
- analysis instrument
- spectrophotometer
- Gas Analyzer
- Storage Box
- medical appliance
Recommended Products
- Automotive Resistance Spot Welding Analyzer
- Medical Syringe Needle Toughness Tester
- Used TA Instruments DMA Q800 Dynamic Mechanical Analyzer
- online water quality monitor
- Whiteness Meter DB22-226
- Basic coating thickness gauge DB20-CM212S
- Anticorrosion Coating Thickness Gauge DB22-CM222H
- TC-YSY3000 Electronic Compression Tester Digital Display Infrared Sealed Portable Automatic Precision
- Electronic peel strength testing machine, tape adhesive product peel testing machine, horizontal tensile testing machine
- Five point heat sealing tester, five point gradient heat sealing tester, automatic heat sealing testing machine
- Manufacturer supplies cardboard box rupture strength tester, cardboard box durability tester with high precision
- Paper, corrugated cardboard, metal foil, folding resistance tester, folding fatigue strength tester, wrinkle resistance tester
Find Similar Products By Category
- Instruments & Meters > Analysis Instrument > Other Analysis Instruments

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Salinna
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile