Home > Products > CONTROLLER > InteliMains GSC SW1IM2GSCXX MainsCompact NT MC-NT InteliLite Telecom IL-NT TLC InteliLite Telecom DC IL-NT TLC-DC InteliBifuel 20 IBF-20 InteliBifuel 2 IBF-2 InteliDrive FLX Lite ID-FLX-LITE InteliDrive Fire Pump ID2DCUINBAA ID2DCUINBLA
InteliMains GSC SW1IM2GSCXX MainsCompact NT MC-NT InteliLite Telecom IL-NT TLC InteliLite Telecom DC IL-NT TLC-DC InteliBifuel 20 IBF-20 InteliBifuel 2 IBF-2 InteliDrive FLX Lite ID-FLX-LITE InteliDrive Fire Pump ID2DCUINBAA ID2DCUINBLA
You May Like
-
MainsCompact NT MC-NT ID2DCUINBAA InteliDrive Mobile ID-MOBILE InteliDrive Mobile Logger ID-MOBILE LOGGER Inteli AIO9/1 I-AIO9/1 AIO9/1 I-AOUT8
-
IS-PCM IGS-NT-LSM+PMS IGS-NT-LSM-PMS IGS-NT-GeCon-PCM IGS-NT-GeCon-LSM+PMS IGS-NT-GeCon-LSM+PMS I-RB16 I-RB8 I-LBA IG-MTU-C IG-MTU-2-1 IG-MTU/MAR IG-MTU Marine
-
InteliVision 8 Marine IL-NT RD IC-NT RD IG-DISPLAY LT GC I-RD-CAN-ID-DCU-MARINE IS-DISPLAY IS-DISPLAY MARINE IS-RD ID-Display D13-V ID-Display 2600
-
ICHG-65-24-A InteliCharger 65 24-A BC224V20BOB InteliCharger 480 24 20A ICHG-120 12-24 ICHG-240 24 ICHG-120 12 ICHG-60-24-AF ICHG-60-24-A
-
DSE2510 DSE2520 DSE8003 MKII DSEP962 DSEP961 DSEP915 DSEP124 DSEP120 DSEP100 DSEL401 BC1205
-
InteliVision 12Touch OEM RD112OEMBZH InteliVision 13Touch RD1IV13TBME MainsPro G99TT MP199TTAAB IGS-LOG-WINSCOPE DONGLE
Product Description
1.2 Mounting the Unit
The unit is designed for panel mounting. The user should not be able to access parts of the unit other than the front panel.
Mount the unit on a flat, vertical surface. The unit fits into an opening of 116x86 millimeters. Before mounting, remove the retaining steel spring and connectors from the unit, then pass the unit through the mounting opening. The unit will be maintained in its position by the steel spring.
The output of the current transformers shall be 5 Amperes. The input current rating of the current transformers may be selected as needed (between 10/5 and 9000/5 amps). Current transformer outputs shall be connected by separate cable pairs from each transformer, to related inputs. Never use common terminals or grounding. The power rating of the transformer should be at least 5 VA. It is recommended to use 1% precision transformers.
If analogue senders (e.g. temperature or oil pressure) are connected to the unit, it is not possible to use auxiliary displays, otherwise the unit may be destroyed. If temperature or oil pressure displays are already present on the generator control panel, do not connect the senders to the unit. The unit is factory programmed for VDO type senders. However different types of senders are selectable via programming menu. Please check the programming section.
The programmable digital inputs are compatible with both ‘normally open’ and ‘normally closed’ contacts, switching either to BAT- or BAT+.
The charge alternator connection terminal provides also the excitation current, thus it is not necessary to use an external charge lamp.
This output provides energy to the generator contactor. If the generator phases do not have acceptable voltage or frequency values, the generator contactor will be de-energized. In order to provide extra security, the normally closed contact of the mains contactor should be serially connected to this output.
This output provides energy to the mains contactor. If the mains phases do not have acceptable voltages, the mains contactor will be de-energized. In order to provide extra security, the normally closed contact of the generator contactor should be serially connected to this output.
The positive terminal of the DC Supply shall be connected to this terminal. The unit operates on both 12V and 24V battery systems.
This relay is used for fuel solenoid control. It is internally connected to terminal 16 for supplying the charge alternator’s excitation current.
Connect the charge alternator’s D+ terminal to this terminal. This terminal will supply the excitation current and measure the voltage of the charge alternator.
Contact Us
- Zhongnan electronic technology co. LTD
- Contact nameLIAO Chat Now
- AddressSHANTOU, Shantou, Guangdong
Product Categories
CONTROLLER |
New Products
-
InteliNano AMF 5 IN2AMF5XBAA IN2AMF5XBAANP Mains (Utility) Protection Relays & Power Meters Manual & Auto Start Control Module
-
Digital Automatic Voltage Regulators AVR Remote Communications & Overview Display IN2AMF5XBAA IN2AMF5XBAANP
-
ComAp Microgrid Controller Remote Display Mains Controller ATS Controller Mains Protections Communications
-
ComAp IC-NT-CT-BIO7 ID-RPU ID-SCM ID-SCM1 IG-IOM IGL-RA15 IG-PCLSM IG-PCLSM/MAR IG-PCM IGS-PTM IL-NT-AIO IL-NT-AOUT8 IL-NT-BIO8
-
ComAp IL-NT-232-485 IL-NT-RS232 IL-NT-GPRS I-LB+ IL-NT-S-USB ID-MOBILE GPRS GNOME Modbus-SNMP Converter
-
DSEG8600 DSEG8660 DSEG8680 DSEM812 DSE9462 DSE335 MKII DSE9130 DSE9150 DSE9155
-
DSE9470 MKII DSE9472 MKII DSE9480 MKII DSE9481 MKII DSE9483 DSE9484 DSE9701 DSE9702 DSE103 MKII
-
DSEA109 DSEP961 DSEP962 DSEP915 DSEP124 DSEP120 DSEP100 Intelligent Battery Chargers and Power Supplies
-
InteliGateway 100 CM2GW100BAB InteliGateway 300 CM2GW300BAB InteliGateway 101 CM2GW101BAB InteliGateway 301 CM2GW301BAB ComAp Extended module, Communications module, I/O input/output module,intelligent charging module
-
ComAp ICHG-60-12-AF ICHG-500 ICHG-60-12-A InteliCharger 120 12-24 ICHG-120 12-24 InteliCharger 240 24 BC124V10BNB
-
ComAp ID-MOBILE GPS I-CR I-CR-R ID-COM IG-COM IG-COM/MAR I-CB/CAT DIESEL I-CB/CAT GAS I-CB/DEUTZTEM I-CB/Modbus I-RD-CAN-ID-DCU-MARINE
-
ComAp InteliLite NT AMF 25 IL-NT AMF25 Auto Mains Failure (AMF) Gen-set Controller
-
ComAp InteliLite NT AMF 20 IL-NT AMF20 Auto Mains Failure AMF Gen-set Controller
-
ComAp InteliLite NT MRS 16 IL-NT MRS16 Manual Remote Start (MRS) Gen-set Controller
-
ComAp InteliLite NT MRS 10 IL-NT MRS10 Manual Remote Start (MRS) Gen-set Controller
-
ComAp InteliLite MRS 16 IL3MRS16BAA Manual Remote Start (MRS) Gen-set Controller
-
ComAp InteliLite MRS 11 IL3MRS11BAA Manual Remote Start MRS Gen-set Controller
-
ComAp InteliLite AMF 25 IL3AMF25BAA Auto Mains Failure (AMF) Gen-set Controller
-
ComAp InteliLite AMF 20 IL3AMF20BAA Auto Mains Failure AMF Gen-set Controller
-
ComAp InteliLite 9 IL3LAMF9BAA single gen-set applications Controller
-
DSE8610 MKII Synchronising & Load Sharing Control Module
-
DSE8660 MKII Auto Transfer Switch & Mains (Utility) Control Module
-
DSE7320 MKII & DSE7320 Auto Mains (Utility) Failure Control Module
-
DSE8620 Synchronising & Load Sharing Auto Mains (Utility) Failure Control Module
Popular Searches
- Generator Parts & Accessories
- Voltage Regulator Avr
- generator parts
- avr
- Ac Part
- Free Energy Permanent Magnet Alternator
- Free Energy Magnet Alternator
- ac spare parts
- generator radiator
- Generator Control Panel
- cooling modules
- Generator Automatic Voltage Regulator
- alternator voltage regulator
- car voltage regulator
- ac dc voltage regulator
- Alternator Voltage Avr
- Generator Avr
- Diesel Generator Avr
- Ac Automatic Voltage Avr
- Generator Ignition Coil
- Generator Part
- generator parts accessories
- Rotating Rectifier
- Rectifier For Generator Alternator
- Marine Spare Part
- Generator Spare Part
- generator spare parts
- recoil starter
- Gasoline Generator Spare Part
- Diesel Generator Part
Recommended Products
- governor test stand Feedback Unit
- governor test stand UEG Actuator Tester
- Reconditioned governor WOODWARD UG-ACTUATOR
- Reconditioned governor WOODWARD UG-25+
- Reconditioned governor WOODWARD UG-10L
- Reconditioned governor ZEXEL RHD6
- Reconditioned governor WOODWARD UG40
- Reconditioned governor WOODWARD 3161
- Reconditioned governor WOODWARD UG-8L
- governor test stand HMM50-A(Economic)
- governor test stand HMM50-AB(Standard)
- 2674A807 Turbocharger Garrett GT2560S TurboPerkins engine 1104 Tier 3 Electronic Fueling CAT C4.4 785828-5002
Find Similar Products By Category
- Industrial Equipment & Components > Power & Generating Sets > Generator Parts & Accessories
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
LIAO
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile