Module spare parts YOKOGAWA A1P830
- xiamen
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
You May Like
Product Details
Brand Name | YOKOGAWA | Model Number | YOKOGAWA A1P830 |
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
YOKOGAWA A1P830 |
The airway module includes a single use D-fend water trap. The water trap has a hydrophobic membrane that prevents condensed water and secretions from entering the airway module measuring chamber. The condensed water and secretions are collected in a washable container. Airway module error alarm messages related to the D-fend are shown until the condition is corrected. Connecting the airway module and module bay The airway module bay may be attached on either side of the ventilator. Do not place the airway module in the lower slot when the airway module bay is on the right side of the system. Exhaust from the gas exhaust port will adversely affect the accuracy of airway module CO2 and O2 measurements. Install only one airway module into the airway module bay. The system does not support the use of multiple airway modules. Only install single width airway modules (E-miniC and CARESCAPE respiratory modules) in the upper right slot of the airway module bay. The upper left slot of the module bay does not support communication between the module and the system. The airway module bay port must only be used for connecting the module bay to the ventilator. 1. Lock the ventilator cart wheels. 2. Connect one end of the cable to the airway module bay connection on the back of the ventilator, and tighten the screws. 3. Attach the module bay to the desired side of the ventilator. ? Loosen the thumbscrews. ? Slide the airway module bay behind the thumbscrews and tighten. 4. Connect the end of the cable to the 2065490-001 Airway modules Airway modules measure and monitor gases delivered to and from the patient. Airway modules have: ? Nondispersive infrared technology to measure CO2, N2O, and anesthetic agents. ? Paramagnetic technology to measure O2. The displayed FiO2 is adjusted by the ratio of the barometric pressure and 1.3 second moving average of the cyclic pressures obtained by the inspiratory pressure transducer. ? Differential pressure detection to measure spirometry inputs from the D-lite(+) or Pedi-lite(+) sensor. ? D-fend water trapping system to prevent moisture from entering the measurement chamber. Some measurements are made by internal sensors in either the ventilator or the airway module. The Airway Module (Patient) data icon is shown below the airway pressure bar when selected as the data source. The Ventilator data icon is shown when it is selected as the data source. Ventilator Data Source Icons Ventilator data Airway Module (Patient) data When Airway Module is selected as the data source, the data source icon will not be updated until the module is able to provide information. This may take 2 to 5 minutes when a module is first installed into the module bay. Only information available from the installed airway module will be displayed on the ventilator; all other data will be from the ventilator. For example, if a module capable of measuring CO2 and O2 only is installed, CO2 and O2 data displayed will be from the module; all other data will be from the ventilator. If Airway Module is selected as the data source and the airway module is removed from the module bay, the data source icon will show Ventilator as the data source. Monitoring that is critical to patient safety comes from both the ventilator and the airway module when the data source is Airway Module. In some conditions, alarms might be triggered by the ventilator sensors, while the measurements shown are from the airway module sensors. The airway module spirometry keys do not function when it is installed in the ventilator. These functions are available through the ventilator.
Contact Us
- Xiamen xiongba e-commerce Co., Ltd
Product Categories
ABB | EPRO | PROSOFT | NI |
REXROTH | Schneider | Miscellaneous brand | EMERSON |
SEW | SIEMENS | GE | SST |
A-B | TRICONEX | WATLOW | WOODWARD |
YAMATAKE | YOKOGAWA | HONEYWEL | BENTLY |
FOXBORO | FSC | ENTERASYS | HIMA |
TRIPLEX |
New Products
-
Module spare parts 05701-A-0301
-
Module spare parts 05701-A-0302
-
Module spare parts 05701-A-0325
-
Module spare parts 05701-A-0326
-
Module spare parts 05701-A-0329
-
Module spare parts 05701-A-0502
-
Module spare parts 05704-A-0121
-
Module spare parts 05704-A-0144
-
Module spare parts07AC91 GJR5252300R0101
-
Module spare parts 07DC91C GJR5251400R0202
-
Module spare parts 07EA90-SI GJR5251200R0101
-
Module spare parts 07KR51 1SBP260011R1001
Popular Searches
Recommended Products
- ABB 2004AP10150A
- ABB 200-IE8/S200-IE8+S200-TB3
- ABB S200-PS13/200-PS1.3
- ABB PHARPSCH100000
- ABB PHARPS32200000 /F8G2B9B3B6
- ABB GH V783 5100 R0000 DZ3510W
- DC filter Reactor
- Dynamic Braking Resistor
- ABB 6240BP10411 6240BP10421 6240BP10431
- ABB XE08B5-d04 1SBP260106R1001
- ABB 07KR51-O22 1SBP260011R1001
- ABB TU515 /1SAP212200R0001
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile