TP867 3BSE043664R1
- 154 Piece / Pieces per Month
- T/T
- 1 days
You May Like
Product Details
Brand Name | ABB | Place of Origin | China | |
Model Number | TP867 3BSE043664R1 |
Product Description
Brand:ABB
Type:TP867 3BSE043664R1
Origin: the Swiss
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
ADMISSION or EXTR/ADM Control The procedure for enabling the Extr/Adm PID with Admission or Extraction/Admission applications is the same. In all cases it is assumed that an external trip valve or a trip-and- throttle valve is used to completely stop any admission steam from entering the turbine upon a system shutdown condition. Admission (Adm) or extraction/admission (Extr/Adm) control can be enabled and performed after one of the three starts has been performed. After a start-up, the HP and LP valve limiters should normally both be fully open. If either limiter is not fully opened, it will interfere with automatic governor operation. To perform a bumpless transfer into Adm or Extr/Adm control the pressures on each side of the Adm trip valve or T&T valve should be matched. The following procedure allows a bumpless transfer into Admission or Extraction/Admission control to be performed.
Adm or Extr/Adm Enabling procedure: 1. Verify that all “Extr/Adm enable permissives” are met (listed above). 2. Match the Extr/Adm setpoint to that of the pressure on the plant side of the Extr/Adm T&T valve. (Skip this step if Setpoint Tracking is used.) 3. Vary the Extr/Adm Demand setpoint to match the turbine’s internal Extr/Adm pressure to that of the pressure on the plant side of the Ext/Adm T&T valve. 4. Open the Extr/Adm Trip-and-Throttle valve. 5. Enable Adm or Extr/Adm control. All the functions required to bumplessly enable and disable Adm or Extr/Adm control can be performed through the 505E keypad, contact inputs, or Modbus. To perform the above procedure from the 505E’s keypad, press the Ext/Adm key to view the Extr/Adm control screen (adjust setpoint), press the Scroll Down key to display the “Extr/Adm Demand” screen (adjust to match pressures), then press the Scroll Up key to display the Extr/Adm Status screen (press the “Yes” key to enable the function). The 505E only accepts an enable command if all related permissives are met (see enable permissive list above). An enable/disable command may be given from the 505E keypad, a contact input, or through Modbus. The last command given from any of these three sources dictates the state of the Extraction control.
When a contact input is programmed to function as an enable/disable command a closed state represents an enable command and an open state represents a disable command. This contact can either be open or closed when a 505E trip condition is cleared. If the contact is open it must be closed to issue an enable command. If the contact is closed, it must be opened and re-closed to issue an enable command. The following procedure allows Adm or Extr/Adm control to be disabled in a controlled manner: Adm or Extr/Adm Disabling procedure: 1. Disable Adm or Extr/Adm control. (At this point the Extr/Adm Demand setpoint will step to the Extr/Adm PID’s last position, take control of the process from the PID, then ramp back to the setting that was used to enable Extr/Adm control. This setting should be at or close to the zero flow level.) 2. If necessary manually adjust the Demand setpoint to reach zero Extr/Adm flow. 3. Close the Extr/Adm Trip-and-Throttle valve.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Product Categories
New Products
-
ICS TRIPLEX T8231
-
PM865K01 3BSE031151R1
-
3BHL000986P0006
-
5SHY3545L0010 3BHB013088R0001 3BHE009681R0101 GVC750BE101
-
5SHY4045L0001 3BHB018162R0001 3BHE009681R0101 GVC750BE101
-
5SHY4045L0006 3BHB030310R0001 3BHE039203R0101 GVC736CE101
Popular Searches
- food processor
- log splitter
- network switch
- network hardware
- cisco module
- industrial computer
- poe splitter
- poe
- poe injector
- cisco
- motherboard
- network equipment
- firewall
- video wall processor
- Audio Processor
- cisco network module
- interface processor
- plug-in module
- route
- led module
- Led Lighting
- laser machine
- fiber optic
- ftth
- diode
- laser equipment
- Laser Diode
- laser module
- media converter
- sfp transceiver
Recommended Products
- Siemens 6ES7332-5HD01-0AB0
- Siemens 6DD1607-0CA1
- Emerson PR6423/010-110 CON021
- Allen Bradley 1769-OF8C
- ABB 3BHE0031482R0101
- ABB DSCA180A 57520001-GY
- ABB ICSF08D1 FPR3323101R1012
- Allen Bradley 2080-LC20-20QWB
- Allen Bradley 1606-XLB480E
- Honeywell DC-TAIX11
- Schneider Electric 140CPU31110
- Emerson PR6423/00R-010-CN CON021/913-030
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile