Brand Name | Honeywell | Place of Origin | China | |
Model Number | FC-PSU-UNI2450U V1.0 |
Product Description
Brand:Honeywell
Type:FC-PSU-UNI2450U V1.0
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
Extraction Turbines The 505E control can be configured to operate single automatic extraction turbines by controlling the interaction of the governor (HP or high pressure) valve and the extraction (LP or low pressure) valve. (The 505E can also operate the governor valve and the first extraction valve of multiple extraction turbines). Single automatic extraction turbines have a high pressure stage and a low pressure stage, each controlled by a valve. Steam enters the turbine through the HP valve (see Figure 1-2). At the downstream end of the HP turbine stage and before the LP valve, steam can be extracted. The LP valve controls the entry of steam into the LP turbine stage, and the diverting of steam through the extraction line. As the LP valve is opened, more steam enters the LP stage and less is extracted. In most cases, the operator of an extraction turbine needs to maintain both turbine speed/ load and extraction pressure/flow at constant levels. Changing the position of either the HP valve or the LP valve affects both turbine speed/load and extraction. If either the load on the turbine or the extraction demand changes, both the HP valve position and the LP valve position must be changed to maintain speed/load and extraction. The movement of both valves is automatically calculated by the 505E’s ratioing logic based on the turbine performance parameters to minimize valve/process interaction.
The 505E control can be configured to operate single automatic admission turbines by controlling the interaction of the governor (HP or high pressure) valve and the extraction (LP or low pressure) valve. Single automatic admission turbines have a high pressure stage and a low pressure stage, each controlled by a valve. Steam enters the turbine through the HP valve (see Figure 1-3) and at the downstream end of the HP turbine stage, before the LP valve. The LP valve controls the entry of steam into the LP turbine stage and through the admission line. As the LP valve is opened, more steam enters the LP stage. In most cases, the operator of an admission turbine needs to maintain both turbine speed/ load and admission pressure/flow at constant levels. Changing the position of either the HP valve or the LP valve affects both turbine speed/load and admission. If either the load on the turbine or the admission demand changes, both the HP valve position and the LP valve position must be changed to maintain speed/load and admission. The movement of both valves is automatically calculated by the 505E’s ratioing logic based on the turbine performance parameters to minimize valve/process interaction.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Product Categories
New Products
Popular Searches
- food processor
- log splitter
- network switch
- network hardware
- cisco module
- industrial computer
- poe splitter
- poe
- poe injector
- cisco
- motherboard
- network equipment
- firewall
- video wall processor
- Audio Processor
- cisco network module
- interface processor
- plug-in module
- route
- led module
- Led Lighting
- laser machine
- fiber optic
- ftth
- diode
- laser equipment
- Laser Diode
- laser module
- media converter
- sfp transceiver
Recommended Products
- Bently Nevada 330101-00-38-90-02-00
- ABB 2004AP10150A
- ABB 200-IE8/S200-IE8+S200-TB3
- ABB S200-PS13/200-PS1.3
- ABB PHARPSCH100000
- ABB PHARPS32200000 /F8G2B9B3B6
- ABB GH V783 5100 R0000 DZ3510W
- DC filter Reactor
- Dynamic Braking Resistor
- ABB 6240BP10411 6240BP10421 6240BP10431
- ABB XE08B5-d04 1SBP260106R1001
- ABB 07KR51-O22 1SBP260011R1001
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile