TOSHIBA 2N3A3120-D
- 146 Piece / Pieces per Month
- T/T
- 1 days
You May Like
Product Details
Brand Name | TOSHIBA | Place of Origin | China | |
Model Number | 2N3A3120-D |
Product Description
Brand:TOSHIBA
Type:2N3A3120-D
Origin: the United States
Warranty: 365 days
Colour: new/used
Shipping method: Courier delivery
Module of PLC, DCS, ESD system card, the card is a vibration monitoring system, steam turbine control system module, the advantages of the gas generator spare parts brand: Allen Bradley, BentlyNevada, ABB, Emerson Ovation, Honeywell DCS, Rockwell ICS Triplex, FOXBORO, Schneider PLC, GE Fanuc, Motorola, HIMA, TRICONEX, Prosoft etc. Various kinds of imported industrial parts
Our main products are widely used in metallurgy, petroleum, glass, aluminum manufacturing, petrochemical industry, coal mine, papermaking, printing, textile printing and dyeing, mechanical, electronic manufacturing, automobile manufacturing, plastic machinery, electric power, water conservancy, water treatment/environmental protection, boiler heating, energy, power transmission and distribution and so on.
ALARM (F1): Displays the reason for any alarm condition (last/newest alarm) when the key’s LED indicator is illuminated. Press the Scroll down arrow (diamond key) to display additional alarms. OVERSPEED TEST ENABLE (F2) : Permits the speed reference to be raised beyond the maximum controlling speed setpoint to test either the electrical or mechanical overspeed trip. F3 (function key): Programmable function key for enabling or disabling programmable control functions. F4 (function key): Programmable function key for enabling or disabling programmable control functions. EMERGENCY SHUTDOWN BUTTON: Large red octagonal button on the front of the enclosure. This is an Emergency Shutdown command for the control. Watchdog Timer/CPU Fault Control A watchdog timer and CPU fault circuit monitors the operation of the microprocessor and microprocessor memory. If the microprocessor fails to reset the timer within 15 milliseconds of the last reset, the CPU fault-control will activate the reset output. This resets the CPU, de-energizes all relay outputs and turns off all milliamp outputs.
This chapter provides instructions on how to mount and connect the 505E into a system. Hardware dimensions, ratings, and jumper configurations are given to allow a customer to mount, wire, and configure the 505E package to a specific application. Electrical ratings, wiring requirements, and options, are provided to allow a customer to fully install the 505E into a new or existing application. Mechanical Data and Hardware Installation If so labeled on the enclosure, the 505E is UL/CUL listed for use in hazardous locations in UL file E156028. This Equipment is suitable for use in Class I, Division 2, Groups A, B, C, and D (Class I, Zone 2, Group IIC) or non-hazardous locations only. This equipment is suitable for use in European Zone 2, Group II environments per compliance with EN60079-15, Electrical apparatus for explosive atmospheres – Type of protection ‘n’ These listings are limited only to those units bearing the certification identification.
Field wiring must be rated at least 75 °C for operating ambient temperatures expected to exceed 50 °C. Wiring must be in accordance with North American Class I, Division 2 or European Zone 2 wiring methods as applicable, and in accordance with the authority having jurisdiction. Peripheral equipment must be suitable for the location in which it is used. WARNING Explosion Hazard–Do not connect or disconnect while circuit is live unless area is known to be non-hazardous. Explosion Hazard–Substitution of components may impair suitability for Class I, Division or Zone applications. AVERTISSEMENT Risque d’explosion–Ne pas raccorder ni débrancher tant que l’installation est sous tension, sauf en cas l’ambiance est décidément non dangereuse. Risque d’explosion–La substitution de composants peut rendre ce matériel inacceptable pour les emplacements de Classe I, applications Division ou Zone. WARNING Do not use any test points on the power supply or control boards unless the area is known to be non-hazardous.
Contact Us
- Temporal Ming sheng automation equipment co., LTD
Product Categories
New Products
Popular Searches
- food processor
- log splitter
- network switch
- network hardware
- cisco module
- industrial computer
- poe splitter
- poe
- poe injector
- cisco
- motherboard
- network equipment
- firewall
- video wall processor
- Audio Processor
- cisco network module
- interface processor
- plug-in module
- route
- led module
- Led Lighting
- laser machine
- fiber optic
- ftth
- diode
- laser equipment
- Laser Diode
- laser module
- media converter
- sfp transceiver
Recommended Products
- ABB 3BHE024747R0101 GDC801A101
- ABB HIEE300900R0001 PPC322 BE
- Bently Nevada 330104-00-16-10-11-00
- ABB SDCS-CON-4 3ADT313900R1501
- Honeywell 51451326-504
- Bently Nevada 330500-00-00
- Bently Nevada 330101-23-34-10-02-05
- Bently Nevada 330902-00-25-10-02-05
- ABB CI867AK01
- ABB CI858K01
- ABB SPHSS03
- ABB CI856K01
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile