Product Details
Brand Name | Dehler | Place of Origin | China | |
Model Number | S11 |
Product Description
Company Introduction:
Dehler Technology Co., Ltd. specializes in producing high and low voltage switchgear, box type substation, cable branch box, outdoor vacuum circuit breaker, isolation switch, grounding switch, load switch and low voltage components and other products.
Product Introduction
The products implement the National Standard GB1094-2013 Power Transformer and GB / T6451-2015 Three-phase Oil-immersed Power Transformer Technical Parameters and Requirements, and are recommended as the major equipment products for the national urban and rural power grid construction and retrofit by the State Economic and Trade Commission.
S11 series transformer adopts high quality material for copper winding, especially applying the new technology and new material for the coil insulation and active parts, thus the no-load and the load loss are obviously reduced, the performance and structure are more reliable and superior.
Product Features
1.Good Economic Performance
The no-load loss for S11 series products decreased 10.3% averagely, no-load current decreased 22.4% based on S9 series.
2.Long Service Life
Transformer tank adopts hermetical structure, tank and tank cover can be connected by bolts or welded firmly, the transformer oil won't contact with air, so that extend the service life effectively.
3.High Operation Reliability
Improve the relevant sealing parts for the tank, increase the reliability and advance the technical level to ensure the reliability of the seal.
4.Small Installation Area
S11-M series transformer tank uses the corrugated plate radiator. When the oil temperature changes, the corrugated plate will proceed thermal expansion, which can replace the role of the oil conservator. the corrugated plate tank has beautiful appearance, less occupied area.
Model and Meaning
Table 1: 6Kv, 10kV & 30kVA-2500kVA Power Transformer With Off Circuit Tap Changer
Rated Capacity (kVA) | Voltage Combination | Connection Group Symbol | No-load Loss R(W) | Load Loss R(W)75oC | Impedance Voltage (%) | No-load Current(%) | Length L(mm) | Width W (mm) | Height H(mm) | Gauge Horizontal*Vertical (mm) | Active parts Weight(Kg) | Oil Weight(Kg) | Total Weight(Kg) | ||
High Voltage (KV) | Tapping Range of High Voltage | Low Voltage (KV) | |||||||||||||
30 | 6 6.3 10 10.5 | ±5% ±2×2.5% | 0.4 | Dyn11 Yzn11 Yyn0 | 100 | 630/600 | 4.0 | 2.8 | 980 | 735 | 1145 | 400*400 | 178 | 78 | 355 |
50 | 130 | 910/870 | 2.5 | 1017 | 758 | 1205 | 450*400 | 240 | 92 | 415 | |||||
63 | 150 | 1090/1040 | 2.4 | 1035 | 785 | 1285 | 450*400 | 285 | 105 | 505 | |||||
80 | 180 | 1310/1250 | 2.2 | 1065 | 800 | 1290 | 450*400 | 330 | 110 | 540 | |||||
100 | 200 | 1580/1500 | 2.1 | 1072 | 820 | 1305 | 450*400 | 345 | 116 | 590 | |||||
125 | 240 | 1890/1800 | 2.0 | 1155 | 1105 | 1310 | 450*550 | 415 | 135 | 705 | |||||
160 | 280 | 2310/2200 | 1.9 | 1235 | 850 | 1535 | 550*550 | 485 | 155 | 835 | |||||
200 | 340 | 2730/2600 | 1.8 | 1282 | 860 | 1557 | 550*550 | 582 | 168 | 965 | |||||
250 | 400 | 3200/3050 | 1.7 | 1310 | 940 | 1605 | 550*550 | 695 | 210 | 1135 | |||||
315 | 480 | 3830/3650 | 1.6 | 1465 | 1120 | 1915 | 660*650 | 855 | 255 | 1520 | |||||
400 | 570 | 4520/4300 | 1.5 | 1440 | 1165 | 1725 | 660*660 | 950 | 295 | 1590 | |||||
500 | 680 | 5410/5150 | 1.4 | 1510 | 1250 | 1845 | 660*650 | 1150 | 320 | 1905 | |||||
630 | 810 | 6200 | 1.3 | 1650 | 1140 | 1920 | 660*650 | 1500 | 435 | 2015 | |||||
800 | 980 | 7500 | 4.5 | 1.2 | 2125 | 1175 | 2315 | 820*820 | 1910 | 760 | 3510 | ||||
1000 | 1150 | 10300 | 1.1 | 2150 | 1380 | 2570 | 820*820 | 2125 | 880 | 3850 | |||||
1250 | 1360 | 12000 | 1.0 | 2355 | 1485 | 2570 | 820*820 | 2605 | 960 | 4610 | |||||
1600 | 1640 | 14500 | 0.9 | 2385 | 1750 | 2630 | 820*820 | 3125 | 1150 | 5420 | |||||
2000 | 1940 | 18300 | 5.0 | 0.4 | 1940 | 1400 | 1700 | 820*820 | 2420 | 780 | 4200 | ||||
2500 | 2290 | 21200 | 0.4 | 2050 | 1480 | 1800 | 820*820 | 2560 | 880 | 4680 |
Notes:
1.The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2.For the transformer of rated capacity up to 500kVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11 or Yzn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
Technical Parameter for S11 Series 20kV Power Transformer With Off Circuit Tap Changer
(KVA)Rated capaci | Voltage Combination | Connection Group Symbol | No-load Loss(W) | Load Loss (W)75oC | No-load Current (%) | Short-circuit Impedance(%) | ||
High Voltage (KV) | Tapping ranges of High Voltage | Low Voltage(KV) | ||||||
30 | 20 | ±5% ±2×2.5% | 0.4 | Dyn11 Yzn11 Yyn0 | 100 | 690/660 | 2.1 | 5.5 |
50 | 130 | 1010/960 | 2.0 | |||||
63 | 150 | 1200/1150 | 1.9 | |||||
80 | 180 | 1440/1370 | 1.8 | |||||
100 | 200 | 1730/1650 | 1.6 | |||||
125 | 240 | 2080/1980 | 1.5 | |||||
160 | 290 | 2540/2420 | 1.4 | |||||
200 | 340 | 3000/2860 | 1.3 | |||||
250 | 400 | 3520/3350 | 1.2 | |||||
315 | 480 | 4210/4010 | 1.1 | |||||
400 | 570 | 4970/4730 | 1.0 | |||||
500 | 680 | 5940/5660 | 1.0 | |||||
630 | 810 | 6820 | 0.9 | 6.0 | ||||
800 | 980 | 8250 | 0.8 | |||||
1000 | 1150 | 11330 | 0.7 | |||||
1250 | 1380 | 13200 | 0.7 | |||||
1600 | 1660 | 15950 | 0.6 | |||||
2000 | 1950 | 19140 | 0.6 | |||||
2500 | 2340 | 22220 | 0.5 |
Notes:
1.The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2.For the transformer of rated capacity up to 500kVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11 or Yzn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
3.The performance parameters in the table are also applicable for HV with dual voltage 20 (10)kV three-phase transformer.
Technical Parameter for S11 Series 35kV Power Transformer With Off Circuit Tap Changer
Model | Voltage Combination | Connection Group Symbol | No-load Loss (W)75oC | Load Loss R(W) | Impedance Voltage (%) | No-load Current(%) | Length L(mm) | Width W(mm) | Height H(mm) | Gauge Horizontal*Vertical (mm) | Active parts Weight(Kg) | Oil Weight(Kg) | Total Weight(Kg) | ||
High Voltage (kV) | Tapping Range of High Voltage% | Low Voltage (kV) | |||||||||||||
50 | 35 38.5 | ±2×2.5% ±5% | 0.4 | Dyn11/ Yyn0 | 160 | 1200/1140 | 6.5 | 1.3 | 1195 | 935 | 1825 | 660*660 | 300 | 330 | 860 |
100 | 230 | 2010/1910 | 1.1 | 1200 | 995 | 1935 | 660*660 | 470 | 383 | 1130 | |||||
125 | 270 | 2370/2260 | 1.1 | 1235 | 940 | 1955 | 660*660 | 550 | 465 | 1335 | |||||
160 | 280 | 2820/2680 | 1.0 | 1285 | 895 | 1950 | 660*660 | 580 | 485 | 1475 | |||||
200 | 340 | 3320/3160 | 1.0 | 1310 | 1150 | 1985 | 660*660 | 680 | 595 | 1755 | |||||
250 | 400 | 3950/3760 | 0.95 | 1450 | 1090 | 2010 | 660*660 | 860 | 650 | 2000 | |||||
315 | 480 | 4750/4530 | 0.95 | 1930 | 1065 | 2320 | 820*820 | 980 | 765 | 2290 | |||||
400 | 580 | 5740/5470 | 0.85 | 1850 | 1165 | 2015 | 820*820 | 1170 | 885 | 2725 | |||||
500 | 680 | 6910/6580 | 0.85 | 2045 | 1205 | 2415 | 820*820 | 1340 | 960 | 3090 | |||||
630 | 830 | 7860 | 0.65 | 2085 | 1240 | 2515 | 660*660 | 1550 | 895 | 3810 | |||||
800 | 980 | 9400 | 0.65 | 2305 | 1615 | 2685 | 820*820 | 1990 | 1030 | 4510 | |||||
1000 | 1150 | 11500 | 0.65 | 2545 | 1540 | 2590 | 1070*1070 | 2415 | 1475 | 5055 | |||||
1250 | 1400 | 13900 | 0.60 | 2495 | 2010 | 2675 | 820*820 | 2480 | 1405 | 5290 | |||||
1600 | 1690 | 16600 | 0.60 | 2680 | 2100 | 2770 | 820*820 | 2600 | 1490 | 5450 | |||||
2000 | 1990 | 19700 | 0.55 | 2790 | 2180 | 2860 | 820*820 | 2720 | 1590 | 5600 | |||||
2500 | 2360 | 23200 | 0.55 | 2900 | 2290 | 2980 | 1070*1070 | 2830 | 1720 | 5760 |
Notes:
1.The Dimension and weight will be changed according to the requirements. These two data in the table will be subject to the factory documents.
2.For the transformer of rated capacity up to 500KVA, the value of load loss above the oblique line in the table is applicable to the connection group Dyn11. The value of load loss under the oblique line is applicable to the connection group Yyn0.
S11 Series 35kV 630kVA-31500kVA Three-phase Dual Winding Power Transformer With Off Circuit Tap Changer
Model | Voltage Combination | Connection Group Symbol | No-load Loss (W) | Load Loss R(W) | No-load Current(%) | Short circuit impedance (%) | Length L(mm) | Width W(mm) | Height H(mm) | Gauge Horizontal*Vertical (mm) | Active parts Weight(Kg) | Oil Weight(Kg) | Total Weight(Kg) | ||
High Voltage (kV) | Tapping Range of High Voltage% | Low Voltage (kV) | |||||||||||||
630 | 35 | ±2×2.5%±5% | 3.15 6.3 10.5 | Yd11 | 830 | 7860 | 0.65 | 6.5 | 2400 | 1700 | 2210 | 820*820 | 2210 | 900 | 3250 |
800 | 980 | 9400 | 0.65 | 2500 | 1850 | 2390 | 820*820 | 2350 | 1030 | 3500 | |||||
1000 | 1150 | 1150 | 0.65 | 2700 | 1950 | 2510 | 820*820 | 2490 | 1180 | 3860 | |||||
1250 | 1400 | 1390 | 0.55 | 2900 | 2050 | 2630 | 820*820 | 2600 | 1350 | 4350 | |||||
1600 | 1690 | 1660 | 0.45 | 3050 | 2130 | 2750 | 820*820 | 2810 | 1580 | 4855 | |||||
2000 | 2170 | 1830 | 0.45 | 3105 | 2195 | 2805 | 1070*1070 | 2800 | 1800 | 5300 | |||||
2500 | 2560 | 1960 | 0.45 | 3150 | 2535 | 2980 | 1070*1070 | 3525 | 2060 | 7665 | |||||
3150 | 35-38.5 | ±2×2.5%±5% | 3.15 6.3 10.5 | 3040 | 2300 | 0.45 | 7.0 | 3920 | 2725 | 2840 | 1070*1070 | 3995 | 2205 | 8565 | |
4000 | 3610 | 2730 | 0.45 | 3310 | 2915 | 3070 | 1070*1070 | 4825 | 2560 | 10115 | |||||
5000 | 4320 | 3130 | 0.45 | 3480 | 3020 | 3145 | 1070*1070 | 5700 | 2635 | 11305 | |||||
6300 | 5240 | 3500 | 0.45 | 8.0 | 3590 | 2905 | 3210 | 1475*1475 | 7120 | 3240 | 13510 | ||||
8000 | 35-38.5 | ±2×2.5% | 3.15 3.3 6.3 6.6 10.5 | YNd11 | 7200 | 3840 | 0.35 | 4070 | 3050 | 3595 | 1475*1475 | 8875 | 3840 | 16690 | |
10000 | 8700 | 4530 | 0.35 | 4106 | 2795 | 3655 | 2000*1475 | 10305 | 3600 | 17690 | |||||
12500 | 1000 | 5380 | 0.30 | 4570 | 3010 | 3840 | 1475*1475 | 12830 | 4310 | 20990 | |||||
16000 | 1210 | 6580 | 0.30 | 5235 | 3295 | 4615 | 2000*1475 | 16010 | 6650 | 27660 | |||||
20000 | 1440 | 7950 | 0.30 | 5360 | 3415 | 4660 | 2000*1475 | 18820 | 7600 | 32170 | |||||
25000 | 1700 | 9400 | 0.25 | 10.0 | 5830 | 3810 | 4860 | 2000*1475 | 22360 | 9800 | 42600 | ||||
31500 | 2020 | 112000 | 0.25 | 6290 | 4290 | 5260 | 2000*1475 | 25110 | 12010 | 49960 |
Note: 1: For the transformer of low voltage 10.5kV, the connection group symbol is applicable to Dyn11.
Note: 2: For the transformer of rated capacity 3150kVA or above, the -5% tapping position is for maximum current tap.
Note: 3: When the annual average load rate for the transformer is between 35% to 45%, the loss value in the table can obtain the highest operational efficiency.
Contact Us
- DEHLER TECHNOLOGY CO.,LTD
- Contact nameAda Chat Now
- Phone86-0577-62787833
Product Categories
circuit breaker | arrester | fuse | switchgear |
insulator | disconnecting switch | transformer | clamp |
Line Hardware |
New Products
-
SPD Home Lightning Protection / Surge / Surge Protector Dl5-20ka-1p Lightning Arrester
-
SPD Home Lightning Protection / Surge / Surge Protector Dl5-10ka-1p Lightning Arrester
-
SPD Household Lightning Protection / Surge / Surge Protector 40ka-1p Communication Signal Lightning Protection
-
Home Lightning Protection Surge Arrester Surge Protector 40ka-3p Communication Signal Lightning Protection SPD
-
SPD Home Lightning Protection Surge Protector 40ka-4p Communication Signal Lightning Protection
-
Surge Lightning Protection Module 40ka-2p Surge Protector Household Lightning Arrester SPD
-
Amorphous Alloy Iron Core Oil-Immersed Distribution Transformer
-
Three Coherent Solid Distribution Transformers with Wound Core
-
Three-Phase Oil-Immersed Solid Distribution Transformer with Wound Core
-
High Voltage Zinc Oxide Arrester Outdoor High-Voltage Arrester
-
Zinc Oxide Surge Arrester High Voltage Composite Arrester
-
High-Voltage Load Zinc Oxide Arrester Capacitor Type Lightning Arrester
-
Hy5wz-108/281 Composite Zinc-Oxide Lightning Surge Arrester
-
Hy5wx-54/150 Outdoor Composite High Voltage 35kv Lightning Arrester
-
Hy5wx-51/134 Outdoor Composite High Voltage 33kv Lightning Arrester
-
Polymeric Metal-Oxide Gapless 35kv Surge Arrester Using in High-Tension Lines
-
Hy5wz-12.7/45 Zinc-Oxide Arrester Metal Oxide Arrester
-
Hy5ws-17/50q Metal Oxide Polymer Housing Surge Lighting Arrester Low Price
-
Hy5ws-17/50 Low Price 17kv Gapless Surge Arrester or Lightning Arrester with Different Types
-
Hy5ws-12.7/50 12.7kv High Voltage Polymer Housed Metal Oxide Arrester
-
10kv Power Distribution Lightning Arrester Zinc Oxide Lightning Arrester
-
7.6kv Power Distribution Gapless Lightning Arrester Zinc Oxide Lightning Arrester
-
Zinc Oxide Arrester Blue (new) 10kv Maintenance-Free Ceramic Arrester
-
35kv Three-Phase Combined Arrester Overvoltage Protector Insulated Zinc Oxide Arrester
Popular Searches
- power supply
- power adapter
- battery charger
- led driver
- power inverter
- power transformer
- Solar Power System
- ac/dc adapter
- current transformer
- High Frequency Transformer
- Electrical Transformer
- ct
- solar inverter
- electronic transformer
- toroidal transformer
- power transmission
- voltage transformer
- Electric Transformer
- Power Distribution Transformer
- Oil Immersed Transformer
- inductor
- Distribution Transformer
- Dry Type Transformer
- Split Core Current Transformer
- bathroom accessories
- home furniture
- bathroom vanity cabinet
- bathroom furniture
- wooden furniture
- wooden cabinet
Recommended Products
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Ada
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile