Baudcom 40Gb/s 40km QSFP+ Transceiver
- Shanghai
- T/T L/C D/P D/A Credit Card PayPal Other
You May Like
Product Details
Brand Name | baudcom | Place of Origin | China | |
Model Number | 1 |
Product Description
Description:
The BD-OPQC40 is a transceiver module designed for 40Km optical communication applications. The design is compliant to 40GBASE-ER4 of the IEEE P802.3ba standard. The module converts 4 inputs channels(ch) of 10Gb/s electrical data to 4 CWDM optical signals, and multiplexes them into a single channel for 40Gb/s optical transmission. Reversely, on the receiver side, the module optically de-multiplexes a 40Gb/s input into 4 CWDM channels signals, and converts them to 4 channel output electrical data.
The central wavelengths of the 4 CWDM channels are 1271, 1291, 1311 and 1331 nm as members of the CWDM wavelength grid defined in ITU-T G694.2. It contains a duplex LC connector for the optical interface and a 38-pin connector for the electrical interface. To minimize the optical dispersion in the long-haul system, single-mode fiber (SMF) has to be applied in this module.
The product is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP Multi-Source Agreement (MSA). It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference.
The module operates from a single +3.3V power supply and LVCMOS/LVTTL global control signals such as Module Present, Reset, Interrupt and Low Power Mode are available with the modules. A 2-wire serial interface is available to send and receive more complex control signals and to obtain digital diagnostic information. Individual channels can be addressed and unused channels can be shut down for maximum design flexibility.
This product converts the 4-channel 10Gb/s electrical input data into CWDM optical signals (light),
by a driven 4-wavelength Distributed Feedback Laser (DFB) array. The light is combined by the
MUX parts as a 40Gb/s data, propagating out of the transmitter module from the SMF. The receiver
module accepts the 40Gb/s CWDM optical signals input, and de-multiplexes it into 4 individual
10Gb/s channels with different wavelength. Each wavelength light is collected by a discrete avalanche photodiode (APD), and then outputted as electric data after amplified first by a TIA and then by a post amplifier.
The BD-OPQC40 is designed with form factor, optical/electrical connection and digital diagnostic interface according to the QSFP Multi-Source Agreement (MSA). It has been designed to meet the harshest external operating conditions including temperature, humidity and EMI interference. The module offers very high functionality and feature integration, accessible via a two-wire serial interface.
Features:
2 4 CWDM lanes MUX/DEMUX design
2 Up to 11.2Gbps per channel bandwidth
2 Aggregate bandwidth of > 40Gbps
2 Duplex LC connector
2 Compliant with 40G Ethernet IEEE802.3ba and 40GBASE-ER4 Standard
2 QSFP MSA compliant
2 Up to 40km transmission
2 Compliant with QDR/DDR Infiniband data rates
2 Single +3.3V power supply operating
2 Built-in digital diagnostic functions
2 Temperature range 0°C to 70°C
2 RoHS Compliant
Applications
2 Rack to rack
2 Data centers Switches and Routers
2 Metro networks
2 Switches and Routers
2 40G BASE-ER4 Ethernet Links
l Absolute Maximum Ratings
Parameter | Symbol | Min. | Typical | Max. | Unit |
Storage Temperature | TS | -40 | +85 | °C | |
Supply Voltage | VCCT, R | -0.5 | 4 | V | |
Relative Humidity | RH | 0 | 85 | % |
l Recommended Operating Environment:
Parameter | Symbol | Min. | Typical | Max. | Unit |
Case operating Temperature | TC | 0 | +70 | °C | |
Supply Voltage | VCCT, R | +3.13 | 3.3 | +3.47 | V |
Supply Current | ICC | 1100 | mA | ||
Power Dissipation | PD | 3.5 | W |
l Electrical Characteristics (TOP = 0 to 70 °C, VCC = 3.135 to 3.465 Volts)
Parameter | Symbol | Min | Typ | Max | Unit | Note |
Data Rate per Channel | - | 10.3125 | 11.2 | Gbps | ||
Power Consumption | - | 2.5 | 3.5 | W | ||
Supply Current | Icc | 0.75 | 1.1 | A | ||
Control I/O Voltage-High | VIH | 2.0 | Vcc | V | ||
Control I/O Voltage-Low | VIL | 0 | 0.7 | V | ||
Inter-Channel Skew | TSK | 150 | Ps | |||
RESETL Duration | 10 | Us | ||||
RESETL De-assert time | 2000 | ms | ||||
Power On Time | 2000 | ms | ||||
Transmitter | ||||||
Single Ended Output Voltage Tolerance | 0.3 | 4 | V | 1 | ||
Common mode Voltage Tolerance | 15 | mV | ||||
Transmit Input Diff Voltage | VI | 150 | 1200 | mV | ||
Transmit Input Diff Impedance | ZIN | 85 | 100 | 115 | ||
Data Dependent Input Jitter | DDJ | 0.3 | UI | |||
Receiver | ||||||
Single Ended Output Voltage Tolerance | 0.3 | 4 | V | |||
Rx Output Diff Voltage | Vo | 370 | 600 | 950 | mV | |
Rx Output Rise and Fall Voltage | Tr/Tf | 35 | ps | 1 | ||
Total Jitter | TJ | 0.3 | UI |
Note:
1. 20~80%
l Optical Characteristics (TOP = 0 to 70°C, VCC = 3.135 to 3.465 Volts)
Parameter | Symbol | Min | Typ | Max | Unit | Ref. |
Transmitter | ||||||
Wavelength Assignment | L0 | 1264.5 | 1271 | 1277.5 | nm | |
L1 | 1284.5 | 1291 | 1297.5 | nm | ||
L2 | 1304.5 | 1311 | 1317.5 | nm | ||
L3 | 1324.5 | 1331 | 1337.5 | nm | ||
Side-mode Suppression Ratio | SMSR | 30 | - | - | dB | |
Total Average Launch Power | PT | - | - | +10.5 | dBm | |
Average Launch Power, each Lane | -2.7 | - | +4.5 | dBm | ||
Difference in Launch Power between any two Lanes (OMA) | - | - | 6.5 | dB | ||
Optical Modulation Amplitude, each Lane | OMA | -0.7 | +5 | dBm | ||
Launch Power in OMA minus Transmitter and Dispersion Penalty (TDP), each Lane | -1.5 | - | dBm | |||
TDP, each Lane | TDP | 2.6 | dB | |||
Extinction Ratio | ER | 5.5 | - | - | dB | |
Transmitter Eye Mask Definition {X1, X2, X3, Y1, Y2, Y3} | {0.25, 0.4, 0.45, 0.25, 0.28, 0.4} | |||||
Optical Return Loss Tolerance | - | - | 20 | dB | ||
Average Launch Power OFF Transmitter, each Lane | Poff | -30 | dBm | |||
Relative Intensity Noise | Rin | -128 | dB/HZ | 1 | ||
Receiver | ||||||
Damage Threshold | THd | 3.8 | dBm | 1 | ||
Average Power at Receiver Input, each Lane | R | -21.2 | -4.5 | dBm | ||
Receiver Power (OMA), each Lane | -1 | dB | ||||
RSSI Accuracy | -2 | 2 | dB | |||
Receiver Reflectance | Rrx | -26 | dB | |||
Receiver Power (OMA), each Lane | - | - | 3.5 | dBm | ||
Stressed Receiver Sensitivity in OMA, each Lane | - | - | -16.8 | dBm | ||
Receiver Sensitivity(OMA), each Lane | Sen | - | - | -19 | dBm | |
Difference in Receive Power between any two Lanes (OMA) | 7.5 | dB | ||||
Receive Electrical 3 dB upper Cutoff Frequency, each Lane | 12.3 | GHz | ||||
LOS De-Assert | LOSD | -22 | dBm | |||
LOS Assert | LOSA | -35 | dBm | |||
LOS Hysteresis | LOSH | 0.5 | dB |
Note:
1. 12dB Reflection
Contact Us
- Shanghai Baudcom Communication Device Co.Ltd
Product Categories
Communication equipment |
New Products
-
1U 16PON Port Baudcom EPON OLT
-
8/16 Ports GEPON OLT Access System
-
PON OEO Repeater EPON Amplifier
-
2PON OEO GPON Repeater Amplifier
-
PON OEO Repeater GPON Amplifier
-
Economical and Practical FTTH GE+FE+CATV GEPON ONU
-
GEPON ONU: 4Fast Ethernet+RF CATV
-
Triple Play ONU:4FE+POTS+CATV
-
Economical Pratical 1GE 3FE wifi EPON ONU
-
8*10/100M GEPON ONU
-
One PON and One Fast Ethernet GEPON ONU
-
4Port Fast Ethernet GEPON ONU
Popular Searches
- optical cable
- copper cable
- optical module
- transceiver module
- cwdm
- optical transceiver
- fiber transceiver
- fiber optic transceiver
- cisco sfp
- Optical Transceiver Module
- sfp+ transceiver
- sfp dwdm
- cwdm sfp
- copper sfp 10gb
- qsfp copper cable
- Qsfp Module
- Optical Cable Qsfp
- qsfp aoc
- qsfp cables
- Module Qsfp
- fiber optic qsfp
- Transceiver Module Cisco Qsfp
- Optic Cable Qsfp
- Optical Transceiver Qsfp
- Gigabit Qsfp
- walkie talkie
- interphone
- fiber optic
- telecommunication
- video transceiver
Recommended Products
- Horizontal type mechanical sealing 50 pairs to max 600 pairs Copper aerial closure from China manufacturer TAEPO for Sale
- 19 inch 12U network server racks Wall mounted data cabinet glass door with curved meshed door panel from China Manufacturer TAEPO
- Rj11 male to Dual RJ11 female 6P4C wall jack telephone line splitter Duplex adapter from China Factory TAEPO
- 180 degree CAT6A 8P8C RJ45 STP shielded Keystone modular jack from China Factory TAEPO
- Sample Free 2 port CAT3 6P4C telephone jack wire connection box from China Factory TAEPO
- Sample Free CAT3 telephone wire connection box with 6P4C RJ11 jack with RoHS Certificate from China Factory TAEPO
- Sample Free UK CAT3 6P6C 1 port RJ11 telephone jack cable junction box from China Factory TAEPO
- Sample Free CAT5E RJ45 8P8C UTP 8 port surface mount box Compatible with both UTP and STP keystone jack
- 86x86mm German style 1 port 2 port RJ45 network face plates for outlets from China Factory TAEPO
- Sample Free 86x86mm UK style 1 port 2 port face plate Compatible with keystone jack
- Telephone MDF ADSL splitter 2+ over POTS for 72 ports splitter block
- Sample Free 3 Electrode Gas Discharge Tube GDT for LSA over voltage protection magazine from China Factory TAEPO
Find Similar Products By Category
- Electrical & Electronics > Antenna > Communication Antenna

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile