Home > Products > Moisture Meter > Hot Sale Digital LDS-1K Coffee moisture meter
Hot Sale Digital LDS-1K Coffee moisture meter
- 800 Set / Sets per Month
- Shanghai
- Credit Card PayPal
You May Like
Product Details
Place of Origin | Zhejiang, China | Brand Name | Reign | |
Model Number | LDS-1K |
Product Description
Specifications
1. Coffee moisture meter2. temperature compensation
3. test coffee bean and coffee furit.
grain moisture meter, seed moisture meter, cereal moisture meter
Because of the zone and species difference and the limitation to the pre-established standard species parameters, it is possible to find the error when using the default parameters defined by the factory. The customer can use following way to calibrate the error and standard to make sure the precision.
1) revisory value confirmation:
Based on the standard samples by means of 105°C over, the corrective value means the standard value minus the test result. For example, the Tested moisture is 13.6% and the actual moisture needed to display is 14%, so we should add 0.4, and the current revisory value is 0.4. Otherwise it will be the negative value.
2) In revising status:
Spill the sample from the instrument, press the species key for long time till flash and then loose it. The red lamp under the low left corner of the display will be bright, and the instrument will display the default revisory value “0.0”. It means that the instrument is now in the revising status;
3) revision:
Press the “+” key to add 0.4, then press the OK key to save. The revision is completed when the lamp flashes. Press the species key or switch off to exit.
The complete procedure refers to following illustration
Standard setup
If you want to add the measurable species or you can prepare the standard sample by yourself, you can use following way to set up the standard.
1) Prepare the standard sample: Prepare three kinds of standard samples with high, middle and low moisture by means of 105°C oven (if the actual Test range is less than 6%, it is enough to only use two standard samples with high and low moisture.). In order to make the standard setup representation and veracity , the moisture in the high and low standard sample must be in the two ends of the actual moisture range. The suitable moisture difference among the standard samples is 3-6%. (for examples: the moisture of wheat is 18%, 14% and 10%)
2) Enter into the standard setup: Spill the sample from the instrument, press the “OK” key for long time and loose it when the display flashes. The red lamp under the low left corner of the display will be bright, and the species code is showed on the display. It indicates that the instrument is now in standard setup.
3) Select the species code: Press “ “ or “ “ key to select the species code.
4) Note the setup order: You should follow the following order to set standard: first is the low moisture, next is the high moisture and final is the middle moisture.
5) Set low moisture standard: take low moisture sample and fall them into the sensor. When the test result is displayed, change the Test result (display 11%) into the standard value (10%). Then press “OK” key and loose it till the digits flash. One standard setup is completed.
For example:
note: one standard setup can be also the approach to calibrate the error.
6) Set high moisture standard: Spill the sample but don’t switch off the instrument. Again take high moisture sample and fall them into the sensor. When the test result is displayed, change the Test result (display 17%) into the standard value (18%). Then press “OK” key and loose it till the digits flash. Two standards setup is completed.
7) Test the standard samples again: Test the standard sample again. If the error is equal or less than 0.5%, it indicates the standard setup is successful. Switch off the instrument to exit the standard setup. If the error is large, it needs to reset the standard setup.
8) The third standard setup: If the gap between the low and high moisture standard sample is too large ( exceed the 6%), the middle moisture standard sample can be used as the third standard setup. The setup approach is the same as it used in high and low moisture standard setup.
Contact Us
- Hangzhou Reign Instrument Co., Ltd.
- Contact nameSteven Wong Chat Now
- Phone0086-571-88039102
- AddressRoom1007,Building B of Ruiding Mansion, NO.200 Zhenhua Road, Sandun , Xihu District, Hangzhou, Zhejiang
Product Categories
New Products
-
high quality UV Integrator
-
SHZ Digital Water Bath Oscillator/ Thermo Shaker
-
portable autoclave pressure steam sterilizer
-
Stainless Steel water Distiller
-
hot sale hand held Handheld Refractometer for 0-100% low price
-
Digital Refractometer
-
Portable Leaf Area Meter for plant in stock
-
Semi-Auto Biochemistry Analyzer
-
Hand pressure type sealing machine
-
Pedal-powered sealing machine
-
Pedal-powered sealing machine Aluminum frame Type
-
Pocket PH Meter
Popular Searches
- Carbon Analyzers
- sulfur analyzer
- element analyzer
- infrared carbon sulfur analyzer
- Carbon Sulfur Analyzer
- Total Organic Carbon Analyzer
- Carbon Sulphur Analyzer
- Silicone Analyzer
- Carbon Silicone Analyzer
- Metal Analyzer
- bet surface area analyzer
- food safety testing equipment
- food safety tester
- fat analyzer
- carbon analyzer
- diffraction
- Infrared Analyzer
- Content Analyzer
- Soil Tester
- Soil Ph Analyzer
- Metal Element Analyzer
- protein analyzer
- plant leaf meter
- Oil Moisture Sensor
- steel analyzer
- Sulfur Content Analyzer
- soil nutrient tester
- Soil Fertilizer Nutrient Tester
- Npk Soil Nutrient Tester
- particle size analyzer
Recommended Products
- ANEMOMETER DB22-236C
- YS264 type sanitary napkin absorption rate tester
- WSB-3A type whiteness meter
- Fully Automated ELISA Analyzer Newton Series
- SEAZENE Auto Blood Grouping System
- Side Pressure Tensimeter DB25-204SPT-5KN-100KN
- Belt Tension Tester DB22-280S
- Optometer Illuminometer LX-1261R
- GB/T 11007 Automatic Electrolyte Conductivity Tester
- ASTM D4603 Viscosity of Polyethylene Terephthalate PET Tester Glass Capillary Viscometer Method
- ASTM D6594 Diesel Engine Oil Corrosion Performance Tester at 135℃
- ASTM D97 D2500 Two-Slot Four-Hole Multi-Function Pour Point and Cloud Point Tester Oil Bath
Find Similar Products By Category
- Instruments & Meters > Analysis Instrument > Other Analysis Instruments
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Steven Wong
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile