Home > Products > Oilfield dedicated instruments and equipments > A80 Gas chromatograph
A80 Gas chromatograph
- 5 Set / Sets per Month
- Shenyang
- T/T D/P D/A
You May Like
Product Details
Place of Origin | Liaoning, China | Brand Name | HK | |
Model Number | A80 |
Product Description
The functions:
- Built-in touch screen industrial PC
- Multi-detector for selection
- Split system with micro-packed column
- Vacuum negative pressures for ample injection
- Automatic selection module of many sample flow paths
- Design of Explosion-proof armor heating
- Integration module design with multi-column and multi-valve
- Sweep protection and leak-tightness automatic sample injection diaphragm valve
A80 Main technical Parameter
- Structural composition
Column box:4 separated electrical heating Column box, working temperature:ambient~350°C Temperature controlling precision: ±0.1°C
Detector: TCD, FID, HID, ECD, PID. working temperature: ambient~350°C
Sampling/ Column cut valve: membrane valve, rolling piston valve, High temperature high Pressure valve, blow through valve Corrosion resistant valve
Chromatographic column: 1/16 1/8packed column, capillary column
EFC: Though max 9 access EFC
- Performance
Measuring scope: TCD: 5ppm~100%, FID: 0.1ppm~100%, HID: ppb~100ppm,
ECD: 0.01ppt~10ppm, PID: 0.1ppb~1000ppm
Repeatability: ±3%RSD
Analytical period: 5 seconds~3hours
- Communication function
LAN TCP:/IP Agreement port open
USB2.0
RS232
- Gas sampling requirements
Sample flow: 10~100ml/min
Sample filter: 2μ
Min pressure: 3~5psi lower pressure can be chosen
Max pressure: 75psi Higher pressure can be chosen
Highest sample temperature standard: 100°C, higher temperature can be chosen
Sampling tube material: Teflon tube, Stainless steel tube, polyimide tube Other materials can be chosen
- Standardization
Mode: manual or automatic
Null point: automatic baseline revise
Measuring scope: steel cylinder Regulator
Quickly on-site logging analysis
One machine with double functions: 25 sec isolates C1~C5, 115 sec isolates C1~C8
All intelligent control, automatic ignition, automatic null point Calibration, automatic fault diagnosis
Measuring scope: component 5*10 -6-100%, total hydrocarbon: 10-5-100%
Natural chromatographic analysis
Separation for many valves and columns, TCD system analysis H2, O2, CH4, CO, C2H6, CO2, H2S, C2H4, C3H8, C3H6, C4, C5, C6+ and ect.
Analytical process
The analytical system consists of a ten connection valve, two 6-way valve, four Chromatographic column and one thermal conductivity detector.
The flow diagram lies in original state, when put the sample into No. 9 mouth of valve V1 into quantitative tube 1, after sweeping clean, switch V1 from OFF to ON, carrier gas 1 takes sample into analytical column DC200, before components flowing out, switch valve 1 from OFF to ON, C6+ was flow back to TCD, examined.
Components O2, N2, CH4, CO, CO2 and C2 flow out from DC200 and flow into chromatographic column PQ, and when components H2S, C3 and above have not flowed out, switch the valve V2 from OFF to ON. Then H2S, C3 and above will be brought into detector TCD by gas carrier 2 and be detected, switch the valve V2 from ON to OFF. Before CO2 and C2 flowing out, O2, N2, CH4, CO flow into chromatographic column 13X, switch the valve V3 from OFF to ON. Components CO2 and C2 will be detected by TCD in sequence. Switch the valve V3 from ON to OFF, components O2, N2, CH4 and CO will be detected. Analysis process finish.
Contact Us
- Liaoning Huake Petroleum Apparatus Science & Technology Co., Ltd.
- Contact nameJack Lee Chat Now
- Phone86-24-23468791
- Address No. 57 Nanwu Road, Heping district, Shenyang, Liaoning,China, Shenyang, Liaoning
Product Categories
New Products
-
Mud viscometer
-
Density sensor
-
HK-A80 Gas chromatograph for comprehensive mud logging
-
HK-A80 comprehensive mud logging gas chromatograph
-
KHH-700 High-purity hydrogen generator
-
Mud water loss meter
-
Mud sand content meter
-
HK-1003C Automatic distillation apparatus for petroleum products
-
Common Glass Container Verification Device (Volumetric Method)
-
Common Glass Container Verification Device (Volumetric Method)
-
Air generator
-
Hydrogen generator
Popular Searches
- Carbon Analyzers
- sulfur analyzer
- element analyzer
- steel alloy analyzer
- infrared carbon sulfur analyzer
- Carbon Sulfur Analyzer
- Total Organic Carbon Analyzer
- Carbon Sulphur Analyzer
- Silicone Analyzer
- Carbon Silicone Analyzer
- Metal Analyzer
- bet surface area analyzer
- food safety testing equipment
- food safety tester
- fat analyzer
- carbon analyzer
- diffraction
- Infrared Analyzer
- Content Analyzer
- Soil Tester
- Soil Ph Analyzer
- Metal Element Analyzer
- protein analyzer
- plant leaf meter
- Oil Moisture Sensor
- steel analyzer
- Sulfur Content Analyzer
- soil nutrient tester
- Soil Fertilizer Nutrient Tester
- Npk Soil Nutrient Tester
Recommended Products
- TKGF-8000A/B Coal quality industrial analyzer Ash determination Coal quality detection
- Wireless Transmission of Cleanliness Monitor: Particle Counter, Temperature, Humidity, Dew Point, and Wind Direction Data Measurement
- ANEMOMETER DB22-236C
- YS264 type sanitary napkin absorption rate tester
- WSB-3A type whiteness meter
- Fully Automated ELISA Analyzer Newton Series
- SEAZENE Auto Blood Grouping System
- Side Pressure Tensimeter DB25-204SPT-5KN-100KN
- Belt Tension Tester DB22-280S
- Optometer Illuminometer LX-1261R
- GB/T 11007 Automatic Electrolyte Conductivity Tester
- ASTM D4603 Viscosity of Polyethylene Terephthalate PET Tester Glass Capillary Viscometer Method
Find Similar Products By Category
- Instruments & Meters > Analysis Instrument > Other Analysis Instruments
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jack Lee
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile