Home > Products > best sellers > stainless steel valve for freon, water oil gas
stainless steel valve for freon, water oil gas
- 500 Piece / Pieces per Month
- FOBshanghai
You May Like
Product Details
Standard or Nonstandard | Standard | Structure | Pilot | |
Pressure | High Pressure | Power | Solenoid | |
Material | Stainless Steel | Temperature of Media | Other, -25℃~100℃ | |
Media | Other, Ammonia Freon CFC,HCFC,HFC,water and E-machine oil with viscosityd | Port Size | 15mm 20mm 25mm | |
Place of Origin | Shanghai, China | Model Number | ADF | |
Brand Name | STF |
Product Description
Specifications
stainless steel valve1.Certificate: CE,CQC ISO9001 and UL
2.CFC HCFC HFC oil gas
3.Biggest client:Carrier,York
stainless steel valve
Features:
1.Coil of this type is hermetic by plastic.It features moisture proof,anti-viberation,and anti-corrosive.All parts are made by stainless steel.It can be used for ammonia and Freon refrigerating system,pneumatic hydraulic and water supply system.
2. suitable for HFC,HCFC refrigerants and Ammonia; clean water ;</=viscosity machine oil
3.Coil type:
AC:24V 36V 110V 220V
DC: 12V 24V 110V 200V
4:opening pressure diff:
AC: 0.05----21bar
DC:0.05-17bar
5:Max working pressure :30bar
6:working range:---25°Ccentigrade to 100°C
Operating principle
ADF series solenoid valve is pilot type valve.When energized the coil,it lead a magnet and pick up plug,open the small orifice,course to pressure in upside of valve reduced.So the pres sure difference happen both side of diaphragm. The pressure difference lift diaphragm to open the main Orifice.When main orifice open,dia phragm shouldnt drop even if pressure difference both side of diaphragm exist too,because of flow inertia function.When coil deenergized,plug drop to close small orifice because of reset spring. Media flow to upside of valve through throttle orifice.Then balance pressure both side of diaphragm,so diaphragm return to close the mail valve.
Installation:
1.The valve must install in horizontal pipe line under vertical position. The flow direction must be meet the arrow direction in valve boby.
2.Installing position should be low viberation.
3.Must install filter before solenoid valve in order to prevent block throttle port and lead to no function.
4.The coil input power must meet rated input power showed on the label.
5.System operating pressure must be meet open valve pertormance.
6.Departure coil from valve when en ergized in coil is limited in order to avoid damage the coil.
7.According to valve with manual function.It must turn manual bar to open the vaNe bemre doing system air tightness, in order to avoid to damage diaphragm.
Contact Us
- Shanghai Thermostat Factory Co., Ltd.
- Contact nameShirly Xiao Chat Now
- Phone86-21-60537189
- AddressNo. 1, Canghui Road
Product Categories
ball valves | best sellers | controls | discharge-bypass valves |
filter dryers | New Products | sight glasses | take-apart expansion valves |
Thermal expansion valves | unloader valves |
New Products
-
constant pressure expansion valve(BV)
-
automatic expansion valve(BV)
-
expansion valve BV series
-
fixed pressure expansion valve(BV)
-
pressure controller device(JC3.5)
-
flow control F-1
-
float switch or cut-off protection
-
float switch or remote switch
-
2-3 way valve for oil, water and freon(FDF1.2S1)
-
2 position 3 way solenoid valvefor oil, water and freon(FDF1.2S1)
-
unloader 3 way solenoid valve
-
non returning valve for HCFC HFC
Popular Searches
- expansion valve
- control valve
- refrigerant r134a
- refrigerant
- Air Conditioner Expansion Valve
- refrigerant gas
- ball valve
- temperature regulator
- Ball Accessory
- forged valve
- Clamp Cast Forged
- cleaning ball
- Clamp Spray Nozzle
- viton
- Butterfly Valve
- pipe thread
- temperature control iron
- Rocker Arm Assembly
- fire valve
- fire extinguishing agents
- Gate Valve
- Gas Control Valve
- Magnet Valve
- flow control
- water flow indicator
- flow valve
- Sample Valve
- freon gas
- gas regulator
- pressure regulator
Recommended Products
- Brand new original genuine inventoryBurkert solenoid valve 00061321 000167415
- DGMFN-H8-Y-A2W-B2W-10 DGMFN-3-Y-A2W-41 DGMR-3-A1-FWA-B1-FWA-50 DGMC2-5-AB-GW-BA-GW-30 DGMC-5-PT-GW-B-30 DGMX2-5-PP-GW-B-30 DGMC2-3-AT-CW-BT-CW-41
- EATON VICKERS DANFOSS DGFN-06-50 DGMFN-3-Y-A1W-B1W-41 DGMR-3-A1-FHB-B1-FHB-50 DGMFN-5-Y-A2W-30 DGMC-5-PT-FW-B-30 DGMX2-5-PB-FW-B-30 DGMFN 3 X B2W 41
- EATON VICKERS DGMPC-7-BAK-30 DGMFN-3-X-A2W-B2W-41 DGMPC-5-ABM-BAM-30 DGMFN-5-Y-A2W-B2W-30 DGMC-5-BT-GW-B-30 DGMX2-5-PA-GW-B-40 DGMFN-3-X-A2W-41
- EATON VICKERS DANFOSS DGMPC-7-ABK-30 DGMFN-3-Y-A2W-B2W-41 DGMPC-5-ABK-30 DGMFN-5-X-A2W-B2W-30 DGMC-5-AT-GW-B-30 DGMX2-3-PP-CW-S-40 DGMC-3-AT-BW-B-41
- EATON VICKERS DANFOSS DGMPC-7-ABK-BAK-21 DGMDC-5-Y-PM-30 DGMPC-5-BAK-30 DGMX2-5-PP-FW-E-B-30 DGMC-5-AT-FW-B-30 DGMX2-3-PP-BW-S-40 DGMC-3-AT-GW-41
- EATON VICKERS DANFOSS DGMPC-7-ABK-BAK-21 DGMDC-5-Y-AK-30 DGMPC-5-ABK-BAK-30 DGMX2-5-PP-BW-E-B-30 DGMC-3-PT-GW-B-41 DGMX2-3-PP-CW-B-40 DGMC-3-AT-CW-41
- EATON VICKERS DANFOSS DGMFN-7-Y-A2W-B2W-30 DGMDC-5-X-TK-30 DGMPC-3-ABN-BAN-41 DGMX2-5-PP-BW-B-30 DGMC-3-PT-CW-B-41 DGMX2-3-PB-CW-B-40 DGMC-3-AT-BW-41
- EATON VICKERS DANFOSS DGMX-7-PP-GW-21 DGMDC-5-Y-PK-30 DGMPC-3-BAK-41 DGMX2-5-PP-AW-B-30 DGMC-3-PT-GW-41 DGMX2-3-PA-AW-B-40 DGMC-3-AT-AW-41
- \DGMX-7-PP-GH-20 DGMDC-3-Y-AK-BK-41 DGMPC-3-ABK-41 DGMX2-5-PB-FW-E-B-30 DGMC-3-PT-CW-41 DGMX2-3-PB-FW-B-40 DGMC2-3-AT-GW-BT-GW-41
- DGMX-7-PP-BH-20 DGMDC-3-Y-BK-41 DGMPC-3-ABM-BAM-41 DGMX2-5-PB-BW-E-B-30 DGMC-3-PT-BW-41 DGMX2-3-PA-FW-B-40 DGMC2-3-AT-CW-BT-BW-41
- DGMC-7-PT-GW-21 DGMDC 3 Y AK 41 DGMPC-3-ABK-BAK-41 DGMX2-5-PB-BW-B-30 DGMC-3-BA-CW-41 DGMX2-3-PP-FW-B-40 DGMC-3-AT-GW-B-41
Find Similar Products By Category
- Industrial Equipment & Components > Valve > Ball Valve
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shirly Xiao
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile