Product Details
Place of Origin | Hunan, China | Brand Name | ZHONGPU SHENGDE | |
Model Number | DXH06-AVC/24 |
Product Description
1. APPLICATION:
This kind of SPD has lots of excellent characteristics, such as low residual voltage, small fading, easy installation and large discharge current capacity. It can protect the power supply, video signal, control part and network of the equipment.
The product is applicable to the video signals of monitoring system, video display, cable TV and home TV for the purpose of protecting the sensitive video lines and of preventing them from being damaged by the induced lightning overvoltage, power interference, and static discharge.
2. NAMING RULES:
3. TECHNICALS PARAMETERS
Model DXH06- | AVC(AN)/24 | ||
Target to be protected | Power Supply | Video part | Control part |
Interface Type | 3P Terminal | BNC | 2P Terminal |
Max. Continuous Operating Voltage (Uc) | 40VAC | 8V | 24V |
Protection Level(Up) | ≤170V | ≤20V | ≤40V |
Load Current(I) | 5A |
|
|
Insert Loss (dB) |
| ≤0.2dB | ≤0.2dB |
Nominal Discharge Current Capacity(In) | 5kA(8/20μs) | ||
Max. Discharge Current Capacity(Imax) | 10kA(8/20μs) | ||
Grounding Resistance(R) | ≤4Ω | ||
Protection Level of the Shell | IP20 | ||
Operating Temperature | -40℃~+70℃ | ||
Overall Size(mm) | 132×75×47 |
4. Installation Method and Attentions
1. Confirm the interface and connecting way.
2. SPD must be wired in series between signal channel and the protected device.
3. The input (IN) of the lightning protector shall be connected with the signal channel, and the output (OUT) shall be with the protected device. They can’t be confused.
4. The grounding shall be reliable and the earth line shall be as short, coarse and straight as possible for purpose of reducing the influence of distributed electric inductance on the discharge of thunder & lightning.
5. No special maintenance is needed for the lightning protector. In case of a fault during the operation, the lightning protector can be dismantled. After that, if the system is operated normally, it is necessary to replace the lightning protector.
5. Certificates:
Contact Us
- Hunan Zhongpu Lightning Protection Co., Ltd.
- Contact nameDerain Tan Chat Now
- Phone86-0731-22461398
- AddressBldg 5, SME Promotion Park, Zhuzhou, Hunan
Product Categories
DC Surge Protection Device | Lightning Protection Socket | New Products | Photovoltaic Surge Protection Device |
Signal Surge Protection Device | Wind Power Generation Surge Protection Device |
New Products
-
50kA 10/350us CLASS I Wind Power Generation Surge Arrester
-
50kA 10/350us CLASS I Wind Power Generation SPD
-
50kA 10/350us CLASS I Wind Power Generation Lightning Protection Device
-
50kA 10/350us CLASS I Wind Power Generation AC Surge Protector
-
50kA 10/350us CLASS I Wind Power Generation 440V Surge Protector
-
50kA 10/350us CLASS I Wind Power Generation Lightning Arrester
-
50kA 10/350us CLASS I Wind Power Generation Under Voltage Protector
-
50kA 10/350us CLASS I Wind Power Generation Surge Protector
-
50kA 10/350us CLASS I Wind Power Generation Lightning Protection
-
Class II N-PE Wind Power Generation Surge Protection Device
-
Class II N-PE Wind Power Generation Outdoor Surge Protector
-
Class II N-PE Wind Power Generation AC Surge Protector
-
Class II N-PE Wind Power Generation 690V Surge Protector
-
Class II N-PE Wind Power Generation Surge Protector
-
Class II N-PE Wind Power Generation Lightning Arrester
-
Class II N-PE Wind Power Generation Lightning Protection
-
Class II N-PE Wind Power Generation Lightning Protection Device
-
Class II N-PE Wind Power Generation 30kA Surge Protector
-
Class II N-PE Wind Power Generation Surge Protection
-
Class II N-PE Wind Power Generation SPD
-
Class II N-PE Wind Power Generation Lightning Surge Protector
-
Class II N-PE Wind Power Generation Surge Arrester
-
Class II N-PE Wind Power Generation Lightning Protector
-
Class II N-PE Wind Power Generation Under Voltage Protector
Popular Searches
- power transformer
- distribution service
- current transformer
- high frequency transformer
- electrical transformer
- energy saver device
- step up converter
- ac drive converter
- frequency drive converter
- lightning conductor
- copper lightning rod
- electronic transformer
- toroidal transformer
- auto transformer
- current transformer inductor
- voltage transformer
- control transformer
- power supply transformer
- led lighting transformer
- waterproof transformer
- electric transformer
- low frequency transformer
- flyback transformer
- core transformer
- output inductor
- power distribution equipment
- power distribution transformer
- transformer substation equipment
- oil immersed transformer
- filter reactor
Recommended Products
- Pepperl+Fuchs HIC2831
- Pepperl+Fuchs HIC2821
- Pepperl+Fuchs HIC2883
- Pepperl+Fuchs KCD2-SCD-EX1
- ABB 3BHE024415R0101 5SHX1060H0003
- ABB HESG 324258 R1 HESG324258R11/P
- TECMOTION SM4065-P32/4.28-E2-500-157-I
- Siemens 6DD2920-0AU1
- Siemens SA5E32882577THT
- Siemens SA5E32882672THT
- Siemens SA5E32882578THT
- ABB 560CVT10
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Derain Tan
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile