Place of Origin | Hunan, China | Brand Name | ZHONGPU SHENGDE | |
Model Number | DXH06-F/3+1AC690R30 |
Product Description
1. APPLICATION
Huge energy released by the lightning would cause the wind turbine blades damaged, insulation breakdown, control components overburdened, etc. Therefore wind power SPD has became one of the powerful guarantees for safe and normal operation of the wind turbine.
2.TECHNICALS PARAMETERS
Model DXH06-F/ | 3+1AC690R30 | 3 AC690R30 |
Type (IEC 61643-1) | Class II /Type 2 | |
Max. Continuous Operating Voltage(Uc) | 1000VAC | 750VAC |
Nominal Continuous Operating Voltage(Un) | 690VAC | 690VAC |
Nominal Discharge Current Capacity (In) | 15kA(8/20μs) | |
Max. Discharge Current Capacity (Imax) | 30kA(8/20μs) | |
Protection Mode | L~PE | |
Protection Level(Up) | ≤4.2kv | ≤3.0kv |
Response Time(T) | <25ns | |
Fault Indicator | Available | |
Live Line(mm² ) | ≥6 | |
Earth line(mm² ) | ≥10 | |
Grounding Resistance(R) | ≤4Ω | |
Protection Level of the Shell | IP20 | |
Operating Temperature | -40℃~+70℃ | |
Overall Size(mm) | 144×90×68 | 54×90×65 |
Installation Method | 35 mm DIN-rail |
3. Wiring Diagram
4. Installation Method and Attentions
1) Wiring as shown in Figure;
2) The connecting lead shall use many strands of copper wires of more than 6mm2, and the earth wire shall use many strands of copper wires of more than 10mm2. The connecting wire shall be as short, straight and coarse as possible. Grounding Resistance should be no less than 4Ω;
3) The front of lightning arrester shall be connected with proper fuse in series or be opened;
4) The power supply must be cut off while conducting the installation. It is prohibited to conduct the operation with the charge. The connecting lead must conform to the requirement;
5) After completing the installation, the lightning protection module shall be inserted tightly and inspected;
6) When there is RED for the fault indicator of the lightning arrester module (warning signal of remote-signaling port), it indicates that the lightning protection module has degraded and shall be replaced;
7) The SPD needn't special maintenance, but only check the connection and indicating state periodically.
5. Certificates:
Contact Us
- Hunan Zhongpu Lightning Protection Co., Ltd.
- Contact nameDerain Tan Chat Now
- Phone86-0731-22461398
- AddressBldg 5, SME Promotion Park, Zhuzhou, Hunan
Product Categories
DC Surge Protection Device | Lightning Protection Socket | New Products | Photovoltaic Surge Protection Device |
Signal Surge Protection Device | Wind Power Generation Surge Protection Device |
New Products
-
48V DC 30kA Lightning Arrester
-
Surge Arrester 48V DC 30kA
-
48V DC 30kA Lightning Protection
-
24V DC 20kA Lightning Arrester
-
24V DC 20kA Lightning Surge Protector
-
24V DC 20kA Lightning Protection
-
Surge Arrester 24V DC 20kA
-
Lightning Surge Protector 48V DC 40kA
-
Surge Protection Device 24V DC 20kA Power Supply
-
48V DC 40kA Lightning Protection
-
SPD 48V DC 40kA Power Supply
-
Surge Arrester 48V DC 40kA
Popular Searches
- power transformer
- distribution service
- current transformer
- high frequency transformer
- electrical transformer
- energy saver device
- step up converter
- ac drive converter
- frequency drive converter
- lightning conductor
- copper lightning rod
- electronic transformer
- toroidal transformer
- auto transformer
- current transformer inductor
- voltage transformer
- control transformer
- power supply transformer
- led lighting transformer
- waterproof transformer
- electric transformer
- low frequency transformer
- flyback transformer
- core transformer
- output inductor
- power distribution equipment
- power distribution transformer
- transformer substation equipment
- oil immersed transformer
- filter reactor
Recommended Products
- JDS UNIPHASE 2214-308LQTC
- JDS UNIPHASE 2214-30SLQTA
- ICS Triplex T9451
- KOYO DL240CPU
- Honeywell FC-PDB-ARTF05
- Allen Bradley A5E32168144
- Allen Bradley 80190-580-01-R?
- Allen Bradley 80190-560-01-R
- Bently Nevada 84661-66
- Bently Nevada 330980-70-05
- Bently Nevada 330910-00-12-10-02-00
- Bently Nevada 330102-00-48-10-02-05
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Derain Tan
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile