Standard or Nonstandard | Standard | Structure | Diaphragm | |
Pressure | Low Pressure | Power | Solenoid | |
Material | Brass | Temperature of Media | Medium Temperature | |
Media | Gas | Port Size | 1/8",1/4",1/2",3/4",1",2" | |
Place of Origin | Gujarat, India | Model Number | L2003, L2004, L2005, L3009,L3012, L3014,L3018 | |
Brand Name | Rotex |
Product Description
Specifications
Pneumatic Latching Solenoid ValveTwo wire Latch coil Can also be supplied
Suitable to operate in high Temperature zone
Make
Latching Solenoid Valve
WORKING PRINCIPLE :
In Fluid Control applications where sudden/ momentary loss of power which can result in safety issues, create a major shut down, affecting up time and in applications where continuous power consumption affects the life of power supply, Latch coil solenoid valves offer the ideal solution.
Using a Magnetic Latching principle, the Latch type solenoid has two coils with opposing windings and a permanent magnet.The solenoid has three terminals, for latching (energizing) and De-latching (de- energizing).
On energizing the Latch coil (either by a pulse of power or continuous power), plunger is pulled and latched magnetically.
The Latch solenoid is designed for continuous energization in case the application demands. Loss of power or switching off the Latch coil will not change the valve position. Momentary pulse to the De-latch coil will de-energize the solenoid valve.Optionally a manual override can also manually Latch/manually De-latch the Solenoid valve.
The Latch type Solenoid system has been designed in a manner to facilitate conversion of single solenoid valve to a stay put the device i.e. on power failure to retain last position. However, Manual override feature on single solenoid valve (if installed) cannot be used to de-energize the Solenoid valve manually. These valve have to be de-enegized electrically.
For AC power supply, a full bridge rectifier is used to convert AC into DC internally.
The latch solenoid can be used to convert any of the rotex single solenoid valve to work as impulse operated for such valve.
The manual override will only latch the valve has to be delatched electrically.
SOLENOID LC
Solenoid has inbuilt two windings and a permanent magnet. Both the windings have inbuilt rectifier. Its one end is common and providing supply to latch coil to pull plunger upward. The magnet keeps plunger pulled and even if supplies to latch coil is removed. The plunger resets when DL coil is momentarily energised.
RC : Rectifier bridge
P : Permanent magnet
LC : Terminal Latch
COM : Common
DL : Delatch terminal
The solenoid consists of single winding and a permanent magnet. The magnet is not strong enough to pull the plunger of its own however it is strong enough to retain the plunger in position once actuated.
The current passed the coil generates magnetic force which assists the magnetic force of the magnet. Due to this plunger gets actuated. Now, due to magnet plunger remains actuated even when power supply to the solenoid is removed.
The plunger can be deactivated by passing current in the coil in reversed direction.
Usually DC powered solenoid can only be offered with this arrangement.
FEATURES :
Continuous duty
Suitable to operate in high temperature zone (near boiler).
Ex d version available
Valves are provided with Manual override for latch.
Most valves can be latched manually by turning knob anticlockwise
and delatched by turning knob clockwise.
In normal condition Manual Override knob has to be maintained in horizontal position
Wide range of 2, 3, 5 port Direct/ Pilot operated Valves can be supplied
Two wire latch coil can also be supplied (Require reversal of
power supply for changing valve Position)
Ambient / Fluid Temperature : - 20°C to 80°C
Media :
Air , Inert , Gases , Water , Oil
Application :
2 , 3 or 5 port single solenoid valve required to retain position in case of power failure.
VALVE TYPE :
Valve Type | Model No. |
2 PORT DIRECT ACTING NORMALLY CLOSED SOLENOID VALVE | L2003 |
2 PORT INTERNAL PILOT OPERATED NORMALLY CLOSED SOLENOID VALVE | L2005 |
3 PORT DIRECT ACTING NORMALLY CLOSED SOLENOID VALVE | L3009 |
3 PORT INTERNAL PILOT OPERATED NORMALLY CLOSED SOLENOID VALVE | L3012 |
3 PORT INTERNAL PILOT OPERATED NORMALLY OPEN SOLENOID VALVE | L3013 |
3 PORT 2 POSITIONS UNIVERSAL EXTERNAL SOLENOID VALVE | L3014 |
3 PORT 2 POSITIONS UNIVERSAL INTERNAL SOLENOID VALVE | L3019 |
3 PORT 2 POSITIONS UNIVERSAL INTERNAL / EXTERNAL SOLENOID VALVE | L3017 |
3 PORT 2 POSITIONS UNIVERSAL INTERNAL / EXTERNAL SOLENOID VALVE | L3018 |
5 PORT 2 POSITIONS SINGLE SOLENOID VALVE | L5004 |
5 PORT 2 POSITIONS SINGLE SOLENOID VALVE | L5005 |
5 PORT 2 POSITIONS SINGLE SOLENOID VALVE | L5006 |
Contact Us
- ROTEX AUTOMATION LIMITED
- Contact nameDeepak Chaudhary Chat Now
- Phone91-265-3044120
- Address987-11, GIDC Estate, Makarpura
Product Categories
Angle Seat Valves | Butterfly Valve | Limit Switch Box | New Products |
Pneumatic Actuators | Pneumatics | Solenoid Valve | Valve automation System |
New Products
-
External Air Operated Solenoid valve
-
2 Port Air Operated Normally Open Solenoid valve
-
2 Port Air Operated Valve
-
Air Operated Normally Closed Solenoid valve
-
High Pressure Solenoid Valve
-
2 way direct acting solenoid valve
-
High Pressure Poppet solenoid Valve
-
5 Port Pilot Operated Solenoid valve, Solenoid Valve
-
5 Port Air Operated Valve
-
5/2 Pilot Operated High Orifice Valve
-
5 way air operated Sub base Poppet valve
-
5 Way Spring return Manifold valve
Popular Searches
- expansion valve
- control valve
- refrigerant r134a
- refrigerant
- Air Conditioner Expansion Valve
- refrigerant gas
- ball valve
- temperature regulator
- Ball Accessory
- forged valve
- Clamp Cast Forged
- cleaning ball
- Clamp Spray Nozzle
- viton
- Butterfly Valve
- pipe thread
- temperature control iron
- Rocker Arm Assembly
- fire valve
- fire extinguishing agents
- Gate Valve
- Gas Control Valve
- Magnet Valve
- flow control
- water flow indicator
- flow valve
- Sample Valve
- freon gas
- gas regulator
- pressure regulator
Recommended Products
- 1/2Double outer wire ball valve,Fixed ball valve,Water heater ball valve,electroplateCopper ball valve,Kitchen ball valve
- 1/2Internal and external threaded ball valve, Gas professional ball valve,Kitchen gas fittings, Copper ball valve,Gas valve switch
- DN15Internal and external threaded ball valve, Gas professional ball valve,Kitchen gas fittings,Copper ball valve,Gas valve switch
- Vickers Solenoid Valve DG4V-3-2A-M-U-H7-60
- ATOS solenoid valve AGMZO-TERS-PS-10 210 I 54
- Vickers Solenoid Valve DGMFN-3-Y-A2W-41
- Vickers Solenoid Valve DG4V-3-2A-M-U-H7-60
- Yuken Hydraulic valve DSG-03-3C2-A220-50-50HZ
- Yuken Hydraulic valve DSG-01-3C60-D24-N1-50
- ATOS solenoid valve DKZOR-AE-171-S5 10
- Vickers Solenoid Valve DG4V-3-6C-M-U-H7-60
- Rexroth Gear Pump AZPF-11-011RCB20MB
Find Similar Products By Category
- Industrial Equipment & Components > Valve > Ball Valve
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Deepak Chaudhary
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile