Home > Products > Power Quality Solution > 600~46000kVAR /6~35kV static synchronous compensator 35kV
600~46000kVAR /6~35kV static synchronous compensator 35kV
- 500 Set / Sets per Month
- Tianjin/Shanghai/Shenzhen China
- T/T
You May Like
Product Details
Place of Origin | Sichuan, China | Brand Name | DHC | |
Model Number | DHSTATCOM | Output Voltage (V) | 35kV |
Product Description
Technical Specifications
DHSTATCOM Series Medium Voltage Static Synchronous Compensator (SVG) | ||
Model | DHSTATCOM | |
Reactive Power | 600kVAR ~ 46000kVAR | |
Voltage | 35KV | |
Frequency | 50/60Hz | |
Control power supply | Single-phase AC220V, OR 3-phase AC380V 50Hz, OR DC power supply 50Hz (optional). | |
Permissible input variation | Voltage: ±10%, frequency: ±5% | |
Control | Main circuit type | Medium Voltage Multi-level IGBT |
Control mode | Voltage, factor, reactive power (optional) | |
Filter cap | 2nd~13th harmonic | |
Response time | complete response≤10ms (10% ~ 90%) | |
Accuracyof reactive power control | 2.5% | |
Reactive power output range | Continuous adjustment from rated inductive to rated capacitive reactive-power. | |
Overload | 125% for 60 seconds | |
Over current | 150% of rated output | |
Efficiency | >98% | |
Main control function | Filter harmonic, compensate reactive power and balance three phases. | |
Protective function | Overload, over current, cooling fan failure, main circuit abnormal etc. | |
Interfaces | Hardwired (optional: Profibus-DP, Modbus, Ethernet, GPRS) | |
Cabinet | Cabinet Material | Steel |
Ingress Protection | IP20 (higher IP available) | |
Vibration | Seismic zone | |
Cooling Method | Air-blast | |
Cabinet Color | RAL7032(other color available) | |
Environment | Operating Temperature | 0℃~+40℃, storage: -5℃~+50℃ (adjustable upon request) |
Operating Humidity | ≤90% | |
Elevation | ≤1000m (adjustable upon request) | |
Installation | Indoor, in a dust free environment free of hazardous or flammable material. | |
Standards | GB, IEC |
Key Features
Dongfang Hitachi provides integrated solutions to meet our customer’s needs on power quality control and management. Our solutions include power quality data collection and analysis, system design, equipment selection & configuration, and system monitoring.
Our DHSTATCOM series, with the latest reactive power compensation technology, truly realizes the dynamic reactive power compensation. This electrical control equipment can provide dynamic reactive power support to the power system, filter out the harmonics, suppress voltage fluctuation and flicker, and correct the three phase unbalance.
Adopted direct power control technology to compensate reactive power
Direct power control technology is applied to enable DHSTATCOM to emit or absorb reactive power as commanded. The commanded reactive power can be fixed (given by the grid scheduling for example), and it can also be instantaneous in the dynamic compensation system.
Adopted multiple algorithms to eliminate harmonics up to 13th order
Applied both Instantaneous and Discrete algorithms, DHSTATCOM series can be used for different load conditions. Its switching frequency is 5kHz, and it can suppress harmonics up to 13th order.
Adopted compensation control technology to balance three-phase voltages
Compensation control algorithms are applied to correct the unbalance of three-phase voltages. When there is large impedance in the system, the commanded reactive current of each phase is obtained using voltage amplitude closed-loop, and balancing three-phase voltages can be accomplished by controlling each of the three phases.
Adopted closed-loop voltage control technology to suppress voltage fluctuation
Closed-loop voltage control technology is applied in DHSTATCOM series to smooth out system voltage fluctuations caused by grid voltage variation or instantaneous change of the loads. The suppression rate on voltage flicker can reach to 5:1 or even higher.
Fast Response Time
Instantaneous response time is less than 1 ms, while conventional response time of Static Var Compensator (SVC) is greater than 20 ms.
Smaller floor space
No need to use large-capacity capacitors and reactor as energy storage components, the floor space required is 50% or even smaller of SVC’s with the same capacity.
Applications
Long Distance Power Transmission
DHSTATCOM can significantly improve the performance of electric power transmission and distribution systems. One or multiple DHSTATCOMs can be installed at power transmission lines to stabilize voltage, reduce transmission loss, and improve grid stability.
Industrial Applications
The impulse reactive power generated by mills and other symmetrical loads can cause voltage drop and fluctuation. Consequently, the electrical equipment cannot work properly, and productivity is affected. Secondly, the transmission facility of the loads is the major source of high-order harmonic pollution. DHSTATCOM can help to solve these problems, keeping the grid voltage stable, improving the power factor and filtering out the harmonics.
Power Supply System of Electric Locomotives
The mainstream electric locomotives may produce serious pollutions to the grid. These single-phase loads cause problems of three-phase unbalance, low power factor, and negative sequence current. Using DHSTATCOM will tackle these issues, and thus enhance the power supply capacity for locomotive traction and improve the electrical equipment utilization.
Wind Farms
Wind power’s uncertainty and turbine’s operating characteristics lead to output power fluctuation, and cause problems of low grid power factor, voltage deviation and flicker, etc. To solve these problems, dynamic reactive power compensation system is needed when large capacity wind power system connects to the grid. DHSTATCOM will help to increase the power factor and reduce the disturbance to the wind turbine. In addition, the mobility and extensibility of the DHSTATCOM series make it possible to be in sync with wind farm’s expansion.
Solar Plants
The solar power plants operate at constant voltage mode with negative feedback control and low reactive power capacity. Therefore, the voltage collapse could happen when grid voltage or sun irradiation fluctuates. Installing DHSTATCOM can enhance the low voltage tolerance, for reducing the probability of off-grid and achieving improved performance of the solar power generation systems.
Other Applications
Electrical substations, mining sites, chemical plants, and ports etc.
Contact Us
- Dongfang Hitachi (CD) Electric Control Equipments Co., Ltd.
- Contact nameEthan Yang Chat Now
- Phone86-028-82857866
- AddressChengdu, Chengdu, Sichuan
Product Categories
New Products | Photovoltaic Power Solution | Power Quality Solution |
New Products
-
STATCOM 35kv svg
-
low voltage svg 380v statcom
-
svg statcom 380V
-
svg statcom 27.5kV
-
PV Inverter 3KW Grid-tied
-
PV Inverter 5KW Grid-tied
-
PV Inverter 10KW Grid-tied
-
PV Inverter 100KW Grid-tied
-
PV Inverter 250KW Grid-tied
-
PV Inverter 500KW Grid-tied
-
PV Inverter 630KW Grid-tied
-
PV Inverter 0.5MW Container Grid-tied
Popular Searches
- solar energy
- Solar Air Conditioning System
- C System
- Solar Power System
- solar power
- solar system
- Bulb System
- battery test system
- power station
- Lighting System
- Wind Turbine System
- solar portable system
- Portable Power Station
- Solar Panel System
- energy system
- new energy system
- power system
- home system
- wind system
- home use system
- solar system power
- Storage System
- Project System
- Solar System Project
- Solar Energy System
- Panel System
- renewable energy
- Solar Generator
- Video System
- Solar Power Plant
Recommended Products
- Solar System 16kw Hybrid Inverter Solution on grid off grid together
- Solar System 16kw Hybrid Inverter Solution on grid off grid together
- Solar Energy System 5kw Hybrid Inverter Solution 51.2V100AH Lithium Battery
- Surgeimmunitytest GB/T17626.5/IEC61000-4-5/EN55035/EN61547/EN55014-2/EN62040-2/ENIEC61851-21-2/EN62920
- ElectricalFastTransient/Burst GB/T17626.4/IEC61000-4-4/EN55035/EN61547/EN55014-2/EN62040-2/ENIEC61851-21-2/EN62920 etc.
- (Radiateddisturbance
- Voltagedips,shortinterruptionsandvoltagevariationsimmunitytest
- ConductedEmission
- Solar Photovoltaic Panels
- Solar Photovoltaic Panels
- Solar Photovoltaic Panels
- Solar Photovoltaic Panels
Find Similar Products By Category
- Metallurgy, Mineral & Energy > Solar & Renewable Energy > Solar Energy System
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Ethan Yang
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile