Home > Products > Power Quality Solution > svg statcom 380V
svg statcom 380V
- Tianjin/Shanghai/Shenzhen China
- T/T
You May Like
Product Details
Place of Origin | Sichuan, China | Brand Name | DHC | |
Model Number | DHSTATCOM | Output Voltage (V) | 0.38kV, 0.48kV, 0.69kV |
Product Description
Technical Specifications
Specification of DHSTATCOMSeries LowVoltage Static Synchronous Compensator | ||
Model | DHSTATCOM | |
Reactive Power | 100kVAR ~ 1000kVAR | |
Voltage | 0.38kV, 0.48kV, 0.69kV | |
Control power supply | Single-phase AC220V, OR 3-phase AC380V 50Hz, (optional). | |
Permissible input variation | Voltage: ±10%, frequency: ±5% | |
Control | Main circuit type | Low Voltage, Two-level, 3P3L/3P4L(optional) |
Control mode | factor, reactive power (optional) | |
Filter cap | 2nd~13th harmonic | |
Response time | complete response≤10ms (10% ~ 90%) | |
Accuracyof reactive power control | 2.5% | |
Reactive power output range | Continuous adjustment from rated inductive to rated capacitive reactive-power. | |
Overload | 120% for 60 seconds | |
Over current | 150% of rated output | |
Efficiency | >97% | |
Main control function | Filter harmonic, compensate reactive power and balance three phases. | |
Protective function | Overload, over current, over voltage, cooling fan failure, main circuit abnormal etc. | |
Interfaces | Hardwired (optional: RS485, Ethernet, GPRS) | |
Cabinet | Cabinet Material | Steel |
Ingress Protection | IP20 (higher IP available) | |
Vibration | Seismic zone | |
Cooling Method | Air-blast | |
Cabinet Color | RAL7032(other color available) | |
Environment | Temperature | Operating: 0℃~+40℃, storage: -5℃~+50℃ (adjustable upon request) |
Operating Humidity | ≤90% | |
Elevation | ≤1000m (adjustable upon request) | |
Installation | Indoors, in a dust free environment free of hazardous or flammable material. | |
Standards | GB, IEC |
Key Features
Dongfang Hitachi provides integrated solutions to meet customer’s needs on power quality control and management. We offer solutions including power quality data collection and analysis, system design, equipment selection & configuration, and system monitoring.
DHSTATCOM series, with the latest reactive power compensation technology, truly realizes the dynamic reactive power compensation. This electrical control equipment can provide dynamic reactive power support to the power system, filter out the harmonics, suppress voltage fluctuation and flicker, and correct the three phase unbalance.
Adopted multiple algorithms to eliminate harmonics up to 13th order
Applied both Instantaneous and Discrete algorithms, DHSTATCOM series can be used for different load conditions. Its switching frequency is 5 kHz, and it can suppress harmonics up to 13th order.
Adopted direct power control technology to compensate reactive power
Direct power control technology is applied to enable DHSTATCOM to generate or absorb reactive power as commanded. The commanded reactive power can be fixed (given by the grid scheduling for example), and it can also be instantaneous in the dynamic compensation system.
Adopted compensation control technology to balance three-phase voltages
Compensation control algorithms are applied to correct the unbalance of three-phase voltages. When there is large impedance in the system, the commanded reactive current of each phase is obtained using voltage amplitude closed-loop, and balancing three-phase voltages can be accomplished by controlling each of the three phases.
Adopted closed-loop voltage control technology to suppress voltage fluctuation
Closed-loop voltage control technology is applied in DHSTATCOM series to smooth out system voltage fluctuations caused by grid voltage variation or instantaneous change of the loads. The suppression rate on voltage flicker can reach to 5:1 or even higher.
Adopted modular design for ease of maintenance and system extension
DHSTATCOM series was designed with modular approach for ease of maintenance. Each module is controlled by a separate chip. In addition, the system includes RS485, DI, DO and other interfaces, which provides flexibility for system extension.
Applications
The applications of Low Voltage DHSTATCOM are mainly in manufacturing sector for controlling harmonic pollution, compensating reactive power, balancing phase voltages, and correcting voltage fluctuations and distortion.
The drive and control devices are essential equipment in the factories of automobile, photovoltaic, chemical, electronics etc. These devices usually adopt the six-pulse rectifier, which introduces very high harmonic content. The electroplating rectifier, tire rubber mixer machine, and tobacco extractor etc. also produce severe harmonics mainly at the order of 5th, 7th, 11th, and 13th. Additionally, the harmonics pollution is worsen as the capacity of SCR based heating equipment in the precision manufacturing is getting bigger.
In the heavy manufacturing, the equipment such as crane, hoist, electric welding machine, rolling mill, and electric arc furnace etc., produce harmonics mainly below the 13th order. Meanwhile the impact from the large loads leads to reactive power changes, and causes great voltage fluctuation. Electric welding machine and some furnaces use two-phase power supply, and introduce three-phase unbalance.
Using DHSTATCOM can effectively solve above mentioned problems including harmonic pollution, voltage fluctuation and distortion. It can improve the power quality to ensure the stable operating environment of the equipment, reduce damage and failure rate, and save energy.
Contact Us
- Dongfang Hitachi (CD) Electric Control Equipments Co., Ltd.
- Contact nameEthan Yang Chat Now
- Phone86-028-82857866
- AddressChengdu, Chengdu, Sichuan
Product Categories
New Products | Photovoltaic Power Solution | Power Quality Solution |
New Products
-
PV Inverter 500KW Grid-tied
-
PV Inverter 630KW Grid-tied
-
PV Inverter 0.5MW Container Grid-tied
-
PV Inverter 1MW Container Grid-tied
-
PV Inverter 1.26MW Container Grid-tied
-
PV Combiner Box
-
PV Offset Box
-
PV Inverter 0.5-3.5KW Off-grid
-
PV Inverter 0.5MW Grid-tied outdoor
-
PV Inverter 0.5MW container Grid-tied outdoor
-
PV inverter 1MW grid-tied outdoor
-
PV inverter 1MW container grid-tied outdoor
Popular Searches
- solar energy
- solar air conditioning system
- c system
- solar power system
- solar power
- solar system
- bulb system
- battery test system
- power station
- lighting system
- wind turbine system
- solar portable system
- portable power station
- solar panel system
- energy system
- new energy system
- power system
- home system
- wind system
- home use system
- solar system power
- storage system
- project system
- solar system project
- solar energy system
- panel system
- renewable energy
- solar generator
- video system
- solar power plant
Recommended Products
- Solar Tracking System Solution HCPV Panel ODM bracket 2 Axies tracking
- Steel structure photovoltaic carport processing manufacturer
- 3" DC Solar Screw Pump SRG Series 80W~1100W
- 3" DC Solar Pump with Plastic Impeller SRP Series 200W~750W
- 3" DC Solar Pump with Plastic Impeller SRP Series 1100W~1500W
- 3" DC Solar Pump with Plastic Impeller SRP Series 500W~1500W
- 4" DC Solar Pump with Plastic Impeller SRP Series 600W~1500W
- 3" DC Solar Pump with SS Impeller SRS Series 300W~1500W
- 4" DC Solar Pump with SS Impeller SRS Series 500W~1500W
- Hybrid Photovoltaic Energy Storage Integrated System 125kW/225kWh SRM-ESTS125-225kWh-400-A
- 6" DC Solar Pump with SS Impeller SRS Series 1100W~1500W
- 3"Hybrid AC/DC Solar Pump with Plastic Impeller SRP-A/D Series 750W~1500W
Find Similar Products By Category
- Metallurgy, Mineral & Energy > Solar & Renewable Energy > Solar Energy System
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Ethan Yang
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile