Home > Products > Dialysis Center Equipments > automatic Dialyzer Reprocessing Machine with double workstation F168-B
automatic Dialyzer Reprocessing Machine with double workstation F168-B
- shanghai/others
- T/T L/C D/P D/A Credit Card PayPal
You May Like
-
RO Water Treatment System for dialysis equipment
-
Hemodialysis Machine for renal failure patients with Double Pump LCD Touch Screen AJ-M2028
-
Dialysis RO Water Treatment Machine for 25-30 beds (1000L/H)
-
RO Water Treatment Machine for 1-4 beds (150L/H) RO-150
-
RO Water Treatment Machine for 15-20 beds (750L/H) RO-750
-
RO Water Treatment Machine for 15-20 beds (750L/H) RO-750
Product Details
Type | Blood Analysis System | Brand Name | Anjue | |
Model Number | F168-B |
Product Description
Specifications
Dialyzer Reprocessing Machine1. with double workstation
2.to sterilize, clean, test and affuse reusable dialyzer
Human-orien
Dialyzer Reprocessing Machine
1. with double workstation
2.to sterilize, clean, test and affuse reusable dialyzer
Human- oriented design of touch control LCD
The picture:
Function
1. F168-A /F168-B dialyzer reprocessing machine are the first automatic dialyzer reprocessing machine in the world, and F168-B with double workstation. Our perfectness comes from professional and advanced technology, that makes our products legal, safe, and stable.
2. F168-A / F168-B Dialyzer Reprocessing Machine are the main device for hospital to sterilize, clean, test and affuse reusable dialyzer used in hemodialysis treatment.
3. Procedure of Reusing Processing:
[Rinse]----Using RO water to rinse dialyzer.
[Clean]----Using disinfectant to clean dialyzer.
[Test] -----Testing blood chamber capacity of dialyzer and whether the membrane is broken or not.
[Disinfect] ---Using disinfectant to affuse dialyzer.
4. Be used in hospital only.
Technical Parameter
Size: F168-A 470mm×380mm×480mm (L*W*H)
F168-B 480mm×380mm×580mm (L*W*H)
Weight: F168-A 30KG,F168-B 35KG
Power Supply: AC 220V±10%, 50Hz-60Hz, 2A
Input power: 150W
Water input pressure: 0.15~0.35 MPa (21.75 P.S.I.~50.75 P.S.I.)
Water input temperature: 10°C~40°C
Minimum water Inlet flow : 1.5L/min
Reprocessing time: about 12 minutes per cycle
Work environment: temperature 5°C~40°C at relative humidity of no more than 80%.
Storage temperature should be between 5°C~40°C at relative humidity of no more than 80%.
Features
PC work station: It can create,save, search the patients database; operation standard of nurse; easily scan the code to send the signal for reprocessor running automatically;
Effective: When reprocessing single or double dialysers at one time.
Cost-effective: compatible with many brands of disinfectant.
Accuracy & safety: automatic disinfectant dilution
Anti-cross infection control: extra blood port header to prevent infection among patients.
Record function: print reprocessing data, such as name, sex, number of case, date, time, etc.
Double printing: built-in printer or optional external printer (adhesive sticker)
Why to choose F168-B Dialyzer Reprocessing?
1. Adopting pulsating current oscillation technique, in the form of positive and reverse rinse as well as positive and reverse UF to eliminate the leftover in dialyzer in a short time to resume cell volume, so as to prolong the life span of dialyzers.
2. The accurate and efficient test of TCV and blood leak, reflect directly the situation of reprocessing, thus assured the safety of the whole course.
3. Rinse, cleaning, testing and disinfectant affusion could be done either respectively or together, suiting different requirements.
4. Functions like reprocessing system setting, disinfection of machine and debugging are introduced under the main menu.
5. The auto setting of reprocessing run the evacuation before affusion, in order to prevent the redilution of disinfectant.
6. The special design of concentration detection ensures the accuracy of disinfectant and safety of disinfection.
7. Human-oriented design of touch control LCD makes the operation easy.
8. Only a tap and the whole reprocessing would run automatically.
9. The stored information of model capacity ultra filtration coefficient etc makes operation easy and accurate.
10.Functions of troubleshooting tips and shooting alarming reflect the situation timely to the operator.
11.The adoption of 41 patents improved the quality while decreased water use (less than 8L once for per dialyzer)
Contraindication
This machine is designed, made and sold for reusable dialyzer only.
The following five kinds of dialyzers can not be reused in this machine
(1) the dialyzer which has been used by the positive hepatitis B virus patient
(2) the dialyzer which has been used by the positive hepatitis C virus patient
(3) the dialyzer which has been used by the HIV carriers or HIV AIDS patient
(4) the dialyzer which has been used by other patient with blood-infectious disease
(5) the dialyzer which has been used by the patient who has an allergy to disinfectant used in reprocessing.
Contact Us
- Anjue Medical Equipment Co., Ltd.
- Contact nameJonathan Dong Chat Now
- Phone86-556-5836185
- AddressBuilding C3-13, Guangcai Business Garden, Anqing, Anhui
Product Categories
New Products
-
RO Water Treatment Machine for 10-12 beds (500L/H) RO-500
-
Hemodialysis Machine AJ-M2028
-
RO Water Treatment Machine for 5-7 beds (250L/H) RO-250
-
High Security Medical Hemodialysis Machine (Double Pump LCD Touch Screen)
-
Hemodialysis Machine AJ-2008B (Double Pump LCD Touch Screen)
-
Hemodialysis Machine AJ-2008B (Double Pump LCD Touch Screen)
-
Blood Dialysis Machine
-
Hemodialysis Machine for sale
-
Hemodialysis Machine AJ-M2028
-
Hemodialysis Machine AJ-2008B (Double Pump LCD Touch Screen)
-
Single Pump LCD Screen AJ-2008A Dialysis Machine Quality Choice
-
High Standard Medical Hemodialysis Machine (Double Pump LCD Touch Screen)
-
Hemodialysis Machine AJ-2008B (Double Pump LCD Touch Screen)
-
Hemodialysis Machine with Double Pump LCD Touch Screen
-
2015 Hot Selling E.N.T. Treatment Unit
-
2016 New Product E.N.T. Treatment Unit AJ-B910
-
2016 New Product E.N.T. Treatment Unit AJ-B920
-
2016 Innovative Integrated Luxury E.N.T. Treatment Unit
Popular Searches
- oxygen tester
- sulfur analysis
- oxygen sensor testing
- Concentration Meters
- concentration sensor
- Alkali Concentration Meter
- nitrogen tester
- tds monitor
- tds meter
- water instruments
- conductivity meter
- ph probe
- ph analyzer
- ph monitor
- Oxygen Meter
- Ion Meter
- Water Quality Meter
- thermometer probe
- digital thermometer probe
- concentration meter
- viscosity tester
- Tuning Meter
- platinum tester
- Water Quality Tester
- computer assisted semen analysis
- water analysis instruments
- Digital Turbidimeter
- water analysis equipment
- digital multi tester
- hour counter
Recommended Products
- Medical Dry Biochemical Analyzer
- NJbinglab PTFE Filter Clip Filtration and Separation of Substances
- NJbinglab PTFE 166mm wafer cassette with acid tank for Wet Etch
- NJbinglab Teflon Hydrogen Fluoride Distillation Condensation Device
- PFA 7ml 15ml Vials Screw Cap with Various Bottoms
- PFA 6000ml Vials Cleaning System with Rack for Isotope Analysis
- ELISA Microplate Reader Emisean
- Pathology Equipment Touch Screen Slide Warmer Laboratory Tissue Slide Dryer
- Pathology Equipment Touch Screen Tissue Flotation Bath Tissue Water Bath
- Oral thermometer, axillary thermometer, mercury thermometer
- Mercury in glass thermometer
- Aps Nesswell Medical Tissue Fully Automated Microtome
Find Similar Products By Category
- Health & Medicine > IVD
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Jonathan Dong
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile