5 inquiries about standard voltage transformer

Dear Sir/Madam, Kindly quote the price and availability of the following items. 1. EXCITATION TRANSFORMER Rating = 500KVA Continuous duty,11KV/265V, 50Hz with 5 tapping positions from 11.55kV to 10.45kV Insulation Class: F, Type: Three Phase two winding Converter transformer Resin insulation Dry type Model: ZSCB9-500/11 Standard: GB1094.11 IEC60076- 11, Certification: ISO9001 Certified Vector group= Yd11 Protection level: IP20 Rated current HV/LV: 26.2/1089A Type of cooling= AN/AF having cooling fans at each phase with temperature controller Rated Impedance =4.15%, Climatic Class: C2 Total mass: 2040kg, Environmental Class: E2, Fire behavior class: F1, Temp. Rise Limit: 80K Insulation level in kV (Line Terminal) HV side: LI/AC75/35 KV Insulation Level in kV (Line Terminal) LV side: LI/AC 0/3 KV 2. STATION SERVICE TRANSFORMER:       Type: Dry type, cast resin insulation Rating: 500KVA Continuous duty,11/0.4kV with 05 tapping positions (from 11.55kV to 10.45kV) ,50Hz. Model: SCB9-500/11, Standard: GB1094.11 IEC60076-11, Certification: ISO9001 Certified Operating condition: Indoor Cooling: AN/AF having cooling fans at each phase with temperature controller Thermal class: F class Rated Impedance: 3.88%, Vector group: Dyn11 Rated current primary side: 26.2A Rated current secondary side: 722A Temperature rise limit: 100K, Protection level: IP20, Total mass: 2090kg, Climatic Class: C2, Environmental Class: E2, Fire behavior class: F1 Insulation level in kV (Line Terminal) HV side: LI/AC75/35 Insulation Level in kV (Line Terminal) LV side: LI/AC 0/3   3. NEUTRAL GROUNDING TRANSFORMER Specifications Transformer Rating:11/0.5/0.11kV, 40KVA Single Phase Model: ZZD-11/1.367F, Certification: ISO9001 Certified, Rated voltage: 11/√3 kV, Rated frequency: 50Hz, Rated Current: 274A, Rated Time: 30 sec Resistance value: 1.367?, Weight: 1500kg

Bangladesh
IP : 144.48.130.**
2025-02-12 18:54:43
Contact Info

Our company is in need of buying Standard Voltage Transformer and Current Transformer Burden with the following specifications: 1. Standard Voltage Transformer Accuracy Class: 0.05% Rated Primary Voltage: 6kV(6/√3kV), 10kV(10/√3kV), 22kV(22/√3kV), 35 kV(35/√3kV) Rated Secondary Voltage: 100V, 100/√3V, 100/3V Power Factor: COSΦ=1.0 Operating Range: 20%-120%).Un Frequency: 50/60Hz Insulation: Epoxy resin casting, Oil Products Structure: With voltage source Input Voltage of the Voltage Source: AC 0-250V 2. Current Transformer Burden Rated Current: 1A and 5A Power Factor and Rated Burden: COSФ=0.8: 1.25/2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA COSФ=1.0: 1.25/2.5/3.75/5/6.25/7.5/10VA Accuracy Class:±3% Operation Range: (5%-120%).In Frequency: 50Hz or 60Hz Withstand Voltage: 2kV/1min Insulation: Air 

Vietnam
IP : 14.174.210.**
2025-01-14 10:05:28
Contact Info

Can you please supply following items: 1- POWER INPUT MODULE STANDARD (BB=20), INPUT VOLTAGE:95-125 VAC, P/N:161956-A01-B20- C00, MADE BY: BENTLY NEVADA---- 4 pieces. 2- POWER TRANSFORMER WITHOUT INTERNAL BARRIERS, P/N:1472623300/12-01, MADE BY: BENTLY NEVADA---- 4 pieces. 3- PRIMARY POWER FUSE AA=01, CC=00 OR 01,250V, 1.5A, TIME LAG, P/N: 01701500, 

Iran (Islamic Republic of)
IP : 2.147.29.**
2024-08-18 17:01:09
Contact Info

PLease send quote for Model Number: SafeHerm-2500/13.8 Usage: Power Distribution Phase: Three Coil Structure: TOROIDAL Coil Number: Two windings Product name: Power distribution transformer Type: Oil immersed type Rated capacity: 2500kVA Primary voltage: 13.2kV/13.8kV Secondary voltage: 400V/230V Frequency: 50/60Hz insualtion voltage: 75kV/35kV Standard: IEC60076 Cooling Method: ONAN Vector group: Dyn11, Yyn0

Canada
IP : 99.130.115.**
2024-05-30 02:06:06
Contact Info

we need up to 10 compact transformer stations every year 10 kV medium voltage to 630 kVA according to German standards. 

Germany
IP : 109.40.241.**
2024-03-03 23:41:46
Contact Info
to page go