Oil Immersed Transformers

Browse 4 global buying requests and sourcing opportunities.
  • Could you kindly provide a quotation for the following items: 1. Light Microscopes x 85. Laboratory Biological Compound Microscope - With Five (5)/Four objective lenses ranging from 10x to 100x Magnification. - Eyepiece of 10x Magnification. - With a Binocular or trinocular head. - Able to achieve a maximum of 1000x Magnification, that is, eye piece 10x objective of 100x. - Power supply of both Main(AC current of about 220V to 240V) and battery powered (DC Current). 2. Sophisticated Microscopes x 4. Microscope Digital Camera (Trinocular Biological). Microscope (Anti - Fungus Coating and Infinite high quality optical system. System (Wide Field eyepiece WF10x/20mm and Backwards. Quintuple nose piece, Infinite plan achromatic objectives 4x, 10x, 40x,100x(oil), Magnification: 40x, 100x, 400x and 1000x. External Transformer type that can be connected to a power bank. Blue colour option, Multifunctional all - in - one camera that integrates a 13.3 - inch display screen and a 4k image acquisition and processing system. 8.0MP Image and video capture, HDMI, WIFI and USB 3.0 Output. LED illumination system, brightness adjustable, double layer Mechanical stage, Abbe Condenser NA1.25 With Iris Diaphragm. Image View software for PC Included. Or equivalent specifications

    Zimbabwe Zimbabwe
    Posted at: 2025-05-29 19:40:00
    ******
  • oil immersed transformers

    Netherlands Netherlands
    Posted at: 2025-04-23 20:20:04
    R
    ******
  • Our company is in need of buying Standard Voltage Transformer and Current Transformer Burden with the following specifications: 1. Standard Voltage Transformer Accuracy Class: 0.05% Rated Primary Voltage: 6kV(6/√3kV), 10kV(10/√3kV), 22kV(22/√3kV), 35 kV(35/√3kV) Rated Secondary Voltage: 100V, 100/√3V, 100/3V Power Factor: COSΦ=1.0 Operating Range: 20%-120%).Un Frequency: 50/60Hz Insulation: Epoxy resin casting, Oil Products Structure: With voltage source Input Voltage of the Voltage Source: AC 0-250V 2. Current Transformer Burden Rated Current: 1A and 5A Power Factor and Rated Burden: COSФ=0.8: 1.25/2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA COSФ=1.0: 1.25/2.5/3.75/5/6.25/7.5/10VA Accuracy Class:±3% Operation Range: (5%-120%).In Frequency: 50Hz or 60Hz Withstand Voltage: 2kV/1min Insulation: Air 

    Vietnam Vietnam
    Posted at: 2025-01-14 10:05:28
    ******
  • PLease send quote for Model Number: SafeHerm-2500/13.8 Usage: Power Distribution Phase: Three Coil Structure: TOROIDAL Coil Number: Two windings Product name: Power distribution transformer Type: Oil immersed type Rated capacity: 2500kVA Primary voltage: 13.2kV/13.8kV Secondary voltage: 400V/230V Frequency: 50/60Hz insualtion voltage: 75kV/35kV Standard: IEC60076 Cooling Method: ONAN Vector group: Dyn11, Yyn0

    Canada Canada
    Posted at: 2024-05-30 02:06:06
    ******