Please quote the following cartridge filter: Inline Filters for 6” Piping Prior to Pump Suction – HDPE Plant (51 - P - 5001). This requirement arises due to suction saturation in pump 51 - P - 5001 caused by polyethylene fines accumulation. Duplex filters with manual changeover lever and swing bolt cover. Service fluid: Hydrocarbons (mainly isobutane) PE fines traces of TEAL or TEB. Maximum particle size: 5?μm. Normal operating temperature: 32.1 – 40?°C. Operating pressure: 7.95?kg/cm2g. Design pressure: 10.54?kg/cm2g. Nominal flow rate: 87.3?m3/h (≈384.6?gpm). Minimum flow rate: 56.47?m3/h (≈249.7?gpm). Fluid density: ~556?kg/m3. Preferred material: Stainless Steel (SS) 316L. Filter elements: Polypropylene and Sintered stainless steel (SS316L) as an option. Duplex bag: filter as an option.
Mexico
Posted at: 2025-08-19 11:30:06J******Email:******