-
100/1A,15VA,50Hz Outdoor Epoxy Casting Current Transformer
Zimbabwe
Posted at: 2025-07-22 15:14:17******Email:****** -
Type: Outdoor epoxy casting current transformer, UV-resistant cycloaliphatic epoxy resin; Rated Insulation Voltage: 40.5kV; Power Frequency withstand voltage: 95kV; Impulse withstand voltage: 185Kv; Current Ratio: 100/1A; Capacity: 15VA; Accuracy: 1/ 5P10; Frequency: 50Hz; Specify Impementation Standards: IEC 60044 - 1; Ask for specify brands, year of manufacture, Tap: Current Ratio (A) and Accuracy Class like 1S1 1S2 100/1, 2S1 2S2 100/1 5P10
Zimbabwe
Posted at: 2025-07-21 15:30:05******Email:****** -
Dear Sir/Madam, Kindly quote the price and availability of the following items. 1. EXCITATION TRANSFORMER Rating = 500KVA Continuous duty,11KV/265V, 50Hz with 5 tapping positions from 11.55kV to 10.45kV Insulation Class: F, Type: Three Phase two winding Converter transformer Resin insulation Dry type Model: ZSCB9-500/11 Standard: GB1094.11 IEC60076- 11, Certification: ISO9001 Certified Vector group= Yd11 Protection level: IP20 Rated current HV/LV: 26.2/1089A Type of cooling= AN/AF having cooling fans at each phase with temperature controller Rated Impedance =4.15%, Climatic Class: C2 Total mass: 2040kg, Environmental Class: E2, Fire behavior class: F1, Temp. Rise Limit: 80K Insulation level in kV (Line Terminal) HV side: LI/AC75/35 KV Insulation Level in kV (Line Terminal) LV side: LI/AC 0/3 KV 2. STATION SERVICE TRANSFORMER: Type: Dry type, cast resin insulation Rating: 500KVA Continuous duty,11/0.4kV with 05 tapping positions (from 11.55kV to 10.45kV) ,50Hz. Model: SCB9-500/11, Standard: GB1094.11 IEC60076-11, Certification: ISO9001 Certified Operating condition: Indoor Cooling: AN/AF having cooling fans at each phase with temperature controller Thermal class: F class Rated Impedance: 3.88%, Vector group: Dyn11 Rated current primary side: 26.2A Rated current secondary side: 722A Temperature rise limit: 100K, Protection level: IP20, Total mass: 2090kg, Climatic Class: C2, Environmental Class: E2, Fire behavior class: F1 Insulation level in kV (Line Terminal) HV side: LI/AC75/35 Insulation Level in kV (Line Terminal) LV side: LI/AC 0/3 3. NEUTRAL GROUNDING TRANSFORMER Specifications Transformer Rating:11/0.5/0.11kV, 40KVA Single Phase Model: ZZD-11/1.367F, Certification: ISO9001 Certified, Rated voltage: 11/√3 kV, Rated frequency: 50Hz, Rated Current: 274A, Rated Time: 30 sec Resistance value: 1.367?, Weight: 1500kg
Bangladesh
Posted at: 2025-02-12 18:54:43******Email:****** -
Our company is in need of buying Standard Voltage Transformer and Current Transformer Burden with the following specifications: 1. Standard Voltage Transformer Accuracy Class: 0.05% Rated Primary Voltage: 6kV(6/√3kV), 10kV(10/√3kV), 22kV(22/√3kV), 35 kV(35/√3kV) Rated Secondary Voltage: 100V, 100/√3V, 100/3V Power Factor: COSΦ=1.0 Operating Range: 20%-120%).Un Frequency: 50/60Hz Insulation: Epoxy resin casting, Oil Products Structure: With voltage source Input Voltage of the Voltage Source: AC 0-250V 2. Current Transformer Burden Rated Current: 1A and 5A Power Factor and Rated Burden: COSФ=0.8: 1.25/2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA COSФ=1.0: 1.25/2.5/3.75/5/6.25/7.5/10VA Accuracy Class:±3% Operation Range: (5%-120%).In Frequency: 50Hz or 60Hz Withstand Voltage: 2kV/1min Insulation: Air
Vietnam
Posted at: 2025-01-14 10:05:28******Email:****** -
Inquiry About Epoxy resin vacuum casting equipment YC-JZ1400
Czech Republic
Posted at: 2024-12-19 18:35:31A******Email:****** -
Can I ask quotation for an dry transformer? MLI W620 DRY TYPE CAST RESIN TRANSFORMER ? 20/0.69 kV ? 2300/2800 kVA ? Dyn11 ? IP31
Portugal
Posted at: 2024-09-16 23:36:05******Email:****** -
Dear Sirs I am interested in the following products they offer: 6 Capacitive Insulator type CG3, 12kV 75 Capacitive Insulator type CG3, 24kV 6 Capacitive Insulator type CG3, 36kV
Peru
Posted at: 2024-02-13 09:40:03V******Email:******