Home > Industrial Equipment & Components > Engine & Part > Engine > Cooling Fan Control Module

Cooling Fan Control Module

Browse 6 global buying requests and sourcing opportunities.
  • Can I buy one of these parts. Asap

    United States United States
    Posted at: 2025-07-26 03:30:03
    ******
  • Need A JAGUAR X-TYPE 2001 - 2009 RADIATOR COOLING FAN CONTROL MODULE Make by Ford Land Rover. Cooling Fan Relay Control Module For Freelander 940004202. Need to buy one for test

    Singapore Singapore
    Posted at: 2025-07-09 13:50:04
    E
    ******
  • Dear Sir/Madam, Kindly quote the price and availability of the following items. 1. EXCITATION TRANSFORMER Rating = 500KVA Continuous duty,11KV/265V, 50Hz with 5 tapping positions from 11.55kV to 10.45kV Insulation Class: F, Type: Three Phase two winding Converter transformer Resin insulation Dry type Model: ZSCB9-500/11 Standard: GB1094.11 IEC60076- 11, Certification: ISO9001 Certified Vector group= Yd11 Protection level: IP20 Rated current HV/LV: 26.2/1089A Type of cooling= AN/AF having cooling fans at each phase with temperature controller Rated Impedance =4.15%, Climatic Class: C2 Total mass: 2040kg, Environmental Class: E2, Fire behavior class: F1, Temp. Rise Limit: 80K Insulation level in kV (Line Terminal) HV side: LI/AC75/35 KV Insulation Level in kV (Line Terminal) LV side: LI/AC 0/3 KV 2. STATION SERVICE TRANSFORMER:       Type: Dry type, cast resin insulation Rating: 500KVA Continuous duty,11/0.4kV with 05 tapping positions (from 11.55kV to 10.45kV) ,50Hz. Model: SCB9-500/11, Standard: GB1094.11 IEC60076-11, Certification: ISO9001 Certified Operating condition: Indoor Cooling: AN/AF having cooling fans at each phase with temperature controller Thermal class: F class Rated Impedance: 3.88%, Vector group: Dyn11 Rated current primary side: 26.2A Rated current secondary side: 722A Temperature rise limit: 100K, Protection level: IP20, Total mass: 2090kg, Climatic Class: C2, Environmental Class: E2, Fire behavior class: F1 Insulation level in kV (Line Terminal) HV side: LI/AC75/35 Insulation Level in kV (Line Terminal) LV side: LI/AC 0/3   3. NEUTRAL GROUNDING TRANSFORMER Specifications Transformer Rating:11/0.5/0.11kV, 40KVA Single Phase Model: ZZD-11/1.367F, Certification: ISO9001 Certified, Rated voltage: 11/√3 kV, Rated frequency: 50Hz, Rated Current: 274A, Rated Time: 30 sec Resistance value: 1.367?, Weight: 1500kg

    Bangladesh Bangladesh
    Posted at: 2025-02-12 18:54:43
    ******
  • would like to have your offer for the supply of the following tender items with lead time and Data sheet. MPPT charge controller, efficiency not less than 92 %, and shall meet the following specifications. voltage, as per technical specifications Controller must utilize passive cooling (not fans); Should allow parallel operation, i.e more than one unit can be connected in parallel. Controllers to be certified CE or UL and to meet at least one for the following or equivalent standards IEC 62509 or IEC 62093; The device should have LED or LCD display. Equipped with SPD in the upstream input for each Charge Controller. Product warranty shall be 5 years. 228 Pcs MPPT Charge Controller Rated 85A - 100 A, at least 150 VDC input voltage. 148 Pcs MPPT Charge Controller Rated 100 A, at least 150VDC input voltage. 83 Pcs MPPT Charge Controller Rated 100 A, at least 450VDC input voltage. Off-Grid Inverter single phase, pure sine wave, 230 V, 50Hz as per below technical specifications. - The inverter shall produce pure sine wave form with provision for battery charger, and it can be configured individually or in parallel - Output frequency shall be 50 Hz - Designed for indoor enclosure not less than IP 20 - Maximum efficiency should be not less than 90 % at full load - To be certified to meet at least CE and UL marking and complaint with IEC 62109 - The device should be integrated with LED indicators or LCD display - It shall allow adjustment of battery voltage and charging current - The device shall allow connection to grid and/or backup generator(s) - The charging function of the inverter/charger shall include battery charging functionality   and the inverter shall be wired in ways that make use of the inverter battery charging   functionality if the installation includes either mains power or a diesel generator. - Protections required: AC overload and load short circuit, overvoltage, overheating and battery reverse polarity - The inverter shall allow internet connection for remote monitoring - Product warranty shall be 5 years. 22 Pcs 7KVA Solar Off-Grid Inverter. 69 Pcs 10KVA Solar Off-Grid Inverter. . 116 Pcs 15KVA Solar Off-Grid Inverter. 

    Pakistan Pakistan
    Posted at: 2025-01-20 22:19:32
    ******
  • Just need one Denso 499300 3591 is it possible to order only one?

    United States United States
    Posted at: 2024-11-03 03:49:05
    ******
  • We need cassette fan coils with a cooling capacity of 7 kW - 80 pcs, 5.5 kW - 15 pcs and 3.5 kW - 8 pcs complete with 3-way valves and infrared control panels. 

    Jordan Jordan
    Posted at: 2024-09-23 17:11:26
    ******