15 inquiries about central air conditioning systems

We require a 10ft hazardous chemical storage container with the following specifications:  
1. Integrated ventilation system and internal spill containment bund compliant with international standards  
2. Equipped with 3kw air conditioning unit suitable for hazardous environments  
3. Must meet ATEX or IEC certification requirements for explosive atmosphere applications  
Quantity required: 1 unit  
Please provide technical specifications and compliance documentation.

India
IP : 103.170.81.**
2025-09-23 19:10:03
Contact Info

We are a cement company in Iraq seeking professional recommendations for industrial conveying systems and compressed air solutions.  
Our primary requirement involves material transportation within cement mill operations. The system should handle standard cement production materials.  
Please propose equipment options suitable for typical cement plant working conditions.  
Critical parameters like conveying capacity and air consumption need your technical suggestions as we haven't finalized specifications yet.

Iraq
IP : 185.254.200.**
2025-09-18 15:40:03
Contact Info

We require marine-approved dual fuel generators for immediate delivery. Specifications must include:

1. Main Generators (3 units):
- 1000KW/750KW capacity options
- 380/440V, 50/60Hz
- Tier II/III compliance
- Central/local/remote control with synchronizing circuits
- Integrated exhaust scupper system and economizer

2. Secondary Generator (1 unit):
- 400KW capacity
- 380/440V, 50/60Hz
- Tier III compliance

3. Emergency Generator (1 unit):
- 45KW capacity
- 380/440V, 50/60Hz
- Tier III compliance

All units must be new/unused/surplus condition with complete foundation components. Priority given to suppliers with ex-stock availability.

Jordan
IP : 94.249.90.**
2025-09-18 05:36:03
Contact Info

We are looking to purchase expansion valves and ball valves for air-conditioning systems. Requirement details:
- Quantity: 250 pieces per size (multiple sizes required)
- Application: R22 refrigerant-based air-conditioning units
- Delivery: Before December 2023
- Budget: Flexible based on product quality and durability

Please provide specifications and compliance certifications for your valves. Material composition and pressure ratings should be clearly stated in quotations.

Kuwait
IP : 188.71.201.**
2025-09-16 10:30:02
Contact Info

Need to verify the maximum lift height of PLD 12 condensate pump for installation in 24000 BTU air conditioning cassette system. Require technical specifications to confirm suitability before procurement.

Brazil
IP : 191.32.153.**
2025-09-16 00:40:04
Contact Info

We require a commercial driving simulator for truck and bus driver training programs. The system must feature full cabin immersion with realistic vehicle response technology, multi-geared manual transmission, and multiple vehicle configurations including semi-trailer, dump truck, garbage truck, concrete truck, and school bus. Essential components include air brake simulation, air ride seats with authentic steering feedback, and adjustable training scenarios with progressive difficulty levels. The simulator should replicate various weather conditions, obstacles, and equipment malfunctions. An instructor station with performance assessment tools and reporting capabilities is required. Warranty coverage and technical support must be included. Delivery within 30 days is expected.

Turkey
IP : 176.240.244.**
2025-09-12 08:40:02
Contact Info

We are seeking to purchase 2-4 containers of condenser and radiator units for automotive air conditioning systems. The required specification is parallel flow type condensers.  
 
Please confirm your production capability for bulk orders and provide technical specifications compatible with modern vehicle models. Reliable manufacturers with OEM experience are preferred.

Bahrain
IP : 37.131.44.**
2025-09-08 19:30:03
Contact Info

We require a prefabricated steel structure hangar covering 1500 m2 with 7-meter eave height, specifically designed for tropical climate conditions. Technical specifications must include:
1. High-performance thermal insulation using minimum 100mm PIR/Rock Wool sandwich panels for walls and 150mm for roof
2. Structural design accommodating evaporative cooling/ventilation systems with air-tight construction
3. Full-service package including material supply (FOB/CIF) and complete on-site installation in Dakar, Senegal
The project will serve as a trampoline park facility. Please confirm capability to handle all technical requirements and provide installation crew.

France
IP : 91.169.211.**
2025-09-05 21:30:06
Contact Info

I need detailed pricing comparison for vertical machining center models with 30-liter capacity and higher configurations. The machine must ensure high stability and precision, equipped with Fanuc control system and Ser Reich air conditioning with Freon cooling. Please specify price differences based on component quality and functional enhancements. Provide technical specifications focusing on rigidity and thermal stability characteristics.

Egypt
IP : 196.133.30.**
2025-09-04 13:20:02
Contact Info

We are interested in obtaining a formal quotation for a HIAP Crane Truck as per the following specifications: Max lifting capacity: 5000 KG; Max lifting moment: 15.5 T.M; Recommended power: 20 KW; Max oil flow of hydraulic system: 36 L/MIN; Max pressure of hydraulic system: 20 MPA; Oil tank capacity: 90 L; Rotation angle: All rotation; Crane weight: 5000 KG; Installation space: 1000 MM; Engine: Diesel, 6 cylinder; Transmission: 200 liters; Other features: Air condition, fog lamp. Kindly send us your best price including delivery time, warranty terms, and payment conditions. Attached is an image with all the required specifications for your reference.

Romania
IP : 188.240.103.**
2025-06-16 19:26:21
Contact Info

We are contacting regarding the procurement of equipment for thermal post - treatment of recovered carbon black (rCB) produced from pyrolysis of end - of - life tires. We are operating a fine grinding and air classification system and looking to integrate a high - temperature thermal treatment stage. Request a proposal (quotation & technical specifications) for required equipment (continuous rotary kiln or tube furnace for rCB thermal treatment, specific working conditions, capacity, temperature range, etc.) and deliverables (main equipment, control cabinet, feeding and discharging systems, etc.). Appreciate response with available models, technical datasheets, and pricing.

Ukraine
IP : 178.165.165.**
2025-06-03 16:53:49
Contact Info

We need to control the humidity in a centrally Air conditioned Arabic Bread production and Packaging area. The humidity of the area is about 80% and need to bring it down to 60 - 65 % . Your advise ?

Nigeria
IP : 2001:16a2:c0dd:.**
2025-03-23 20:47:08
Contact Info

we urgently need you to provide us an estimate FOB and CF price of a turnkey hyper-intensive (high density stocking around 500kg/m3), RAS Industrial Fish farm with fresh water RAS to grow out tilapia and catfish up to 1kg in 4 months. The plant will be located in Douala Cameroon in Central Africa Region, by the riverside with water available between 25 to 35°C. Specification as follow: Treatment Capacity:  to be design Complete Tilapia line recirculating aquaculture system (RAS) with a capacity of 500 T/cycle and another Complete catfish line recirculating aquaculture system (RAS) with a capacity of 500 T/cycle normally containing Automatic feeding system and Design work. Furthermore, we will need your support and quotation for: a)     General planning of the complete project. b)    Detailed design of the fish pools including piping system  and the workshops. c)     Planning of the different recirculation systems according to the fish biology and production goal. d)    Planning of incoming water and waste water treatment. e)      Planning of the total energy supply (electricity, air/oxygen, cooling/heating) equipment supply. f)     Assembling of the RAS, test run and training of the staff for RAS running, training of the farm’s staff and professional start of the operationalization of the project. g)     During the initial operation and later on, we need your know-how and experience (Maybe to hire a Chinese operation director for a year). 

South Africa
IP : 102.132.24.**
2024-11-11 04:20:49
Contact Info

Need  2 Air Condition Units with 2 difference Specifications as below 1-A : Air Condition Unit ( ACU )   Function Cooling, Ventilation Cooling Capacity:65RT (226Kw) Air Flow:4,000~10,000m3/h ( 176.3~440.7lb/min,80.67~215.5 kg/min) Air Pressure:55~90mBar Air Temperature:Cooling: 1 ~5℃ Refrigerant:R134a / 45Kg Noise:<82dB@4.5m away Air outlets Quantity:1 Dimension (L*W*H)6,345x2,460x2,730(mm) Weight:7,500kg Engine Brand:FPT(IVECO) Power:232Kw@ 1,500RPM Displacement:8. 1L Emission Stage Ⅲ,Tier 3 Generator:Brand:Marathon Power:180Kw@ 1,500RPM Compressor Brand:Copeland Compressor Type:Scroll Compressor Quantity 4 1-B : Air Condition Unit (ACU) Engine:Diesel Cooling Capacity:65 Tons Air Flow:375 lbs/min Compressor:Frick Rotary Screw Automatic pressure:controlled capacity Dimensions:Trailer: 203"Lx 86" W x 93" H (516 x 218 x 236 cm)(Approximate) Weight:Trailer: 9,700 lbs.(4,410 kg) Electrical System:24 Volt Refrigerant:R134a system maintains much more of its operating efficiency inextrem

United States
IP : 104.28.246.**
2024-08-04 23:09:40
Contact Info

We would like to request a quote with your best conditions of Price and Delivery Time for the items as below: Cooling machine for laser treatment
air cooler, cool system, cold wind, cold, wind, cooler

Brazil
IP : 177.69.197.**
2024-07-23 15:10:11
Contact Info
to page go