- 
                        
Require 1 unit of 1000-1500 kVA dry type transformer for testing purpose. Must convert 600V to 415V with Canada certification. Specifically needed for cryptocurrency mining application. No rush delivery required. Please provide technical specifications and compliance documentation.
                                            Canada
                                        Posted at: 2025-09-13 12:40:04
                                            ******Email:****** - 
                        
We need PU resin materials for industrial drying applications. Please specify the types of polyurethane resin available and provide pricing details. Kindly confirm product specifications and minimum order quantities. Awaiting your prompt response with technical information.
                                            Nigeria
                                        Posted at: 2025-09-11 16:50:07
                                            ******Email:****** - 
                        
Type: Outdoor epoxy casting current transformer, UV-resistant cycloaliphatic epoxy resin; Rated Insulation Voltage: 40.5kV; Power Frequency withstand voltage: 95kV; Impulse withstand voltage: 185Kv; Current Ratio: 100/1A; Capacity: 15VA; Accuracy: 1/ 5P10; Frequency: 50Hz; Specify Impementation Standards: IEC 60044 - 1; Ask for specify brands, year of manufacture, Tap: Current Ratio (A) and Accuracy Class like 1S1 1S2 100/1, 2S1 2S2 100/1 5P10
                                            Zimbabwe
                                        Posted at: 2025-07-21 15:30:05
                                            ******Email:****** - 
                        
Looking for a desiccant type dehumidifier for transformer drying operation. 30C RH 90% air should be dried to the maximum possible limit to feed to the drying chamber. Ideally the moisture level of 2.93g per 1 kg of dry air output is preferred from the dehumidifier. Required air flowrate is 30 - 60m3/h. Please recommend a suitable dehumidifier to be purchased.
                                            Sri Lanka
                                        Posted at: 2025-07-21 11:39:21
                                            ******Email:****** - 
                        
                                            ******Email:****** - 
                        
Dear Sir/Madam, Kindly quote the price and availability of the following items. 1. EXCITATION TRANSFORMER Rating = 500KVA Continuous duty,11KV/265V, 50Hz with 5 tapping positions from 11.55kV to 10.45kV Insulation Class: F, Type: Three Phase two winding Converter transformer Resin insulation Dry type Model: ZSCB9-500/11 Standard: GB1094.11 IEC60076- 11, Certification: ISO9001 Certified Vector group= Yd11 Protection level: IP20 Rated current HV/LV: 26.2/1089A Type of cooling= AN/AF having cooling fans at each phase with temperature controller Rated Impedance =4.15%, Climatic Class: C2 Total mass: 2040kg, Environmental Class: E2, Fire behavior class: F1, Temp. Rise Limit: 80K Insulation level in kV (Line Terminal) HV side: LI/AC75/35 KV Insulation Level in kV (Line Terminal) LV side: LI/AC 0/3 KV 2. STATION SERVICE TRANSFORMER: Type: Dry type, cast resin insulation Rating: 500KVA Continuous duty,11/0.4kV with 05 tapping positions (from 11.55kV to 10.45kV) ,50Hz. Model: SCB9-500/11, Standard: GB1094.11 IEC60076-11, Certification: ISO9001 Certified Operating condition: Indoor Cooling: AN/AF having cooling fans at each phase with temperature controller Thermal class: F class Rated Impedance: 3.88%, Vector group: Dyn11 Rated current primary side: 26.2A Rated current secondary side: 722A Temperature rise limit: 100K, Protection level: IP20, Total mass: 2090kg, Climatic Class: C2, Environmental Class: E2, Fire behavior class: F1 Insulation level in kV (Line Terminal) HV side: LI/AC75/35 Insulation Level in kV (Line Terminal) LV side: LI/AC 0/3 3. NEUTRAL GROUNDING TRANSFORMER Specifications Transformer Rating:11/0.5/0.11kV, 40KVA Single Phase Model: ZZD-11/1.367F, Certification: ISO9001 Certified, Rated voltage: 11/√3 kV, Rated frequency: 50Hz, Rated Current: 274A, Rated Time: 30 sec Resistance value: 1.367?, Weight: 1500kg
                                            Bangladesh
                                        Posted at: 2025-02-12 18:54:43
                                            ******Email:****** - 
                        
Our company is in need of buying Standard Voltage Transformer and Current Transformer Burden with the following specifications: 1. Standard Voltage Transformer Accuracy Class: 0.05% Rated Primary Voltage: 6kV(6/√3kV), 10kV(10/√3kV), 22kV(22/√3kV), 35 kV(35/√3kV) Rated Secondary Voltage: 100V, 100/√3V, 100/3V Power Factor: COSΦ=1.0 Operating Range: 20%-120%).Un Frequency: 50/60Hz Insulation: Epoxy resin casting, Oil Products Structure: With voltage source Input Voltage of the Voltage Source: AC 0-250V 2. Current Transformer Burden Rated Current: 1A and 5A Power Factor and Rated Burden: COSФ=0.8: 1.25/2.5/3.75/5/6.25/7.5/10/12.5/15/20/25/30/40/50/60VA COSФ=1.0: 1.25/2.5/3.75/5/6.25/7.5/10VA Accuracy Class:±3% Operation Range: (5%-120%).In Frequency: 50Hz or 60Hz Withstand Voltage: 2kV/1min Insulation: Air
                                            Vietnam
                                        Posted at: 2025-01-14 10:05:28
                                            ******Email:****** - 
                        
Can I ask quotation for an dry transformer? MLI W620 DRY TYPE CAST RESIN TRANSFORMER ? 20/0.69 kV ? 2300/2800 kVA ? Dyn11 ? IP31
                                            Portugal
                                        Posted at: 2024-09-16 23:36:05
                                            ******Email:****** - 
                        
Inquiry About Dry type Distribution Transformer UL
                                            Germany
                                        Posted at: 2024-06-20 17:37:47M******Email:******