3 inquiries about air cooling fan

Brand: salzer Model: PD160M-220 looking for air cooling fan

China
IP : 101.78.126.**
2025-05-02 14:10:04
Contact Info

Inquiry about AC Servo Motor 

Motor type                                         : 3 Phase IP -54 Asychronous Servo Motor Existing Make/Type                        : SOLPower /SVM-132M-10 Voltage Delta Connected           : 220V Current Delta Connected           : 50.08Amps Power                                                  :15 Kw Torque                                                   :142N-m Speed                                                     : 6000 RPM Max Frequency                                           : 201 HZ Max Encoder                                              : 1024 PPR  VDC Motor Mounting                               : Flange Monted PCD 300mm, Mounting Hold ID19mm Drive end shaft                                : Dia 42mm x Length 110mm with key shaft W12xL88xH4 MM Non Drive end shaft                     : Encoder Mounted Cooling Method                              : with Forced Air Cooling Fan BCF 225 ,AC 230 Volt

India
IP : 122.184.59.**
2025-04-28 19:23:56
Contact Info

 Please select a two-section fan cooling tower. The power of one section is 1276 kW. Water temperature at the entrance to the cooling tower is 30 C Water temperature at the outlet of the cooling tower is 25 C Outdoor air temperature according to wet thermometer 22 C The presence of a heated pan to prevent freezing. The design of the cooling tower must ensure operation in the mode: one section is working, the other is reserve and vice versa. The design of the cooling tower must ensure the ability of one section to operate completely with the shut-off valves drained off and drained from the reserve section SOW pipelines. The pool of sections must be separated by a partition so that one of the sections can be completely drained. Return water parameters: - pH - 8.64; - total hardness - 5.52 mEq/l; - concentration of petroleum products -0.39 mg/dm3; - chloride ion concentration - 22.0 mg/dm3; - concentration of suspended substances - 12.7 mg/dm3; The service life of all elements of the cooling tower, with the exception of the load-bearing frame, pan (bowl), pipelines, fan and enclosing structures, is at least 10 years. The service life of the load-bearing frame, tray (bowl), pipelines, fan and enclosing structures is at least 15 years. The equipment must be equipped with drives based on brushless (non-contact) or asynchronous motors. 

Belarus
IP : 178.127.8.**
2024-07-15 20:01:03
Contact Info
to page go