Home > Buyer Service > air cooling fan
- Inquiries by Catalogs
- Security & Protection
- Office Supplies
- Packaging & Printing
- Electrical & Electronics
- Textile
- Service
- Apparel & Accessories
- Industrial Equipment & Components
- Arts & Crafts
- Chemicals
- Computer Products
- Furniture
- Construction & Decoration
- Transportation
- Agriculture & Food
- Auto, Motorcycle Parts & Accessories
- Light Industry & Daily Use
- Toys
- Tools & Hardware
- Bags, Cases & Boxes
- Consumer Electronics
- Metallurgy, Mineral & Energy
- Health & Medicine
- Instruments & Meters
- Sporting Goods & Recreation
- Lights & Lighting
- Manufacturing & Processing Machinery
3 inquiries about air cooling fan
Brand: salzer Model: PD160M-220 looking for air cooling fan
- China
- IP : 101.78.126.**
- 2025-05-02 14:10:04
Inquiry about AC Servo Motor
Motor type : 3 Phase IP -54 Asychronous Servo Motor Existing Make/Type : SOLPower /SVM-132M-10 Voltage Delta Connected : 220V Current Delta Connected : 50.08Amps Power :15 Kw Torque :142N-m Speed : 6000 RPM Max Frequency : 201 HZ Max Encoder : 1024 PPR VDC Motor Mounting : Flange Monted PCD 300mm, Mounting Hold ID19mm Drive end shaft : Dia 42mm x Length 110mm with key shaft W12xL88xH4 MM Non Drive end shaft : Encoder Mounted Cooling Method : with Forced Air Cooling Fan BCF 225 ,AC 230 Volt
- India
- IP : 122.184.59.**
- 2025-04-28 19:23:56
Please select a two-section fan cooling tower. The power of one section is 1276 kW. Water temperature at the entrance to the cooling tower is 30 C Water temperature at the outlet of the cooling tower is 25 C Outdoor air temperature according to wet thermometer 22 C The presence of a heated pan to prevent freezing. The design of the cooling tower must ensure operation in the mode: one section is working, the other is reserve and vice versa. The design of the cooling tower must ensure the ability of one section to operate completely with the shut-off valves drained off and drained from the reserve section SOW pipelines. The pool of sections must be separated by a partition so that one of the sections can be completely drained. Return water parameters: - pH - 8.64; - total hardness - 5.52 mEq/l; - concentration of petroleum products -0.39 mg/dm3; - chloride ion concentration - 22.0 mg/dm3; - concentration of suspended substances - 12.7 mg/dm3; The service life of all elements of the cooling tower, with the exception of the load-bearing frame, pan (bowl), pipelines, fan and enclosing structures, is at least 10 years. The service life of the load-bearing frame, tray (bowl), pipelines, fan and enclosing structures is at least 15 years. The equipment must be equipped with drives based on brushless (non-contact) or asynchronous motors.
- Belarus
- IP : 178.127.8.**
- 2024-07-15 20:01:03