Home > Products > TRICONEX > TRICONEX AI6700 – Analog Input Module for TMR Safety And Critical Control
TRICONEX AI6700 – Analog Input Module for TMR Safety And Critical Control
≥1 Combos
- T/T
- 7 days
You May Like
-
TRICONEX 9750-210F – Field Termination Assembly for Tricon SIS I/O
-
TRICONEX 9566-810 – Termination Assembly for Triconex TMR I/O Wiring And Field Signal Marshalling
-
TRICONEX 9561-810 – Tricon SIS Module/Accessory for High-Integrity Safety Control
-
TRICONEX 8311N – TMR I/O Module for High-Integrity Tricon Safety Systems
-
TRICONEX 9563-810 – Field Termination Assembly for Tricon TMR I/O
-
TRICONEX 8120E – Termination/Field Wiring Module for Triconex Safety And Control I/O
Product Details
HS Code | 9032899090 | Stock Status | In Stock | |
Product Color | Brand New OR Used | Warranty | 12-month Warranty | |
Trademark | TRICONEX | Origin | USA |
Product Description
Brand / Model | TRICONEX AI6700 |
Module Type | Analog Input module for Triconex safety controllers |
Power Requirements | Backplane-powered via Triconex chassis (no external module PSU) |
Signal Inputs | Process analog inputs (typically 4–20 mA; other ranges depending on variant and configuration) |
Communication Interface | Triconex backplane bus; field wiring via dedicated termination assemblies |
Operating Temperature | Typically suitable for control cabinet environments (consult module datasheet for exact range) |
Installation Method | Plug-in to Triconex chassis with removable terminal wiring |
Diagnostics | Built-in channel and module health monitoring; system alarm integration |
Note: Specific channel counts, ranges, and options can vary by AI6700 revision. If you share your exact part/revision code, I can verify precise I/O details.
Application FieldsOil & Gas ESD and HIPPS loops where resilient 4–20 mA measurement is essential.
Refinery and petrochemical BMS/F&G systems, often mixed with discrete safety I/O.
Power generation boiler protection and turbine auxiliary safety monitoring.
Pharmaceutical and specialty chemicals, especially for SIL-rated dosing or interlocks.
Water/Wastewater critical process interlocks and chlorine handling safety loops.
Reliability under load – The TMR design helps mask single-point failures and keep loops online.
Compatibility – Works within Triconex system tooling and diagnostics, reducing engineering time.
Lifecycle savings – Stable platform and spares availability typically lower total cost over long maintenance cycles.
Maintainability – Clear fault reporting and removable terminals make it faster to swap or troubleshoot.
“We replaced a mix of third-party isolators with AI6700 cards on our Tricon racks. Loop checks were quicker and we’ve had fewer spurious trips,” noted a maintenance lead at a Gulf Coast chemical plant.
Installation & MaintenanceCabinet & environment – Install in a rated control cabinet with adequate ventilation. Keep ambient within the specified temperature range and avoid high-vibration panels.
Wiring – Use shielded twisted-pair for analog loops; terminate shields at the designated point to minimize ground loops. Verify loop power (for 4–20 mA) and observe polarity.
Grounding – Maintain a clean instrument ground; separate power and signal grounding where possible to reduce noise pickup.
Commissioning – Perform loop checks and simulate signal ranges. From my experience, documenting as-found/as-left values speeds up audits later.
Routine maintenance – Periodically inspect terminals for looseness or corrosion, clean dust with dry air, and schedule proof tests according to your SIL verification plan.
Firmware/config – Align module firmware and controller versions as recommended; back up configuration before any changes.
Hot-swap readiness – Triconex systems typically support safe module replacement procedures; follow site MOC and bypass rules during swaps.
Triconex platform TüV-certified to IEC 61508 for SIL3 architectures when properly applied.
Compliance typically includes CE and UL/CSA marks for industrial control equipment.
RoHS conformity appears on many recent revisions; confirm per module revision and region.
Manufacturer warranty as per Triconex policy; extended service and spares programs commonly available.
Certifications can vary by catalog number and hardware revision. Share your exact AI6700 variant for a compliance check.
Compatible Components & Helpful AccessoriesTriconex system chassis and backplane (Tricon or Tricon CX) suitable for the AI6700 slot footprint.
Dedicated termination assemblies or marshalling panels for clean field wiring and shield management.
Loop power supplies and fused terminal blocks for 4–20 mA instruments.
Surge protection devices (SPD) for analog loops in lightning-prone areas.
If you can provide the AI6700 part/revision code and your required signal ranges, I’ll map the exact channel capabilities, wiring diagrams, and any HART pass-through options supported by your hardware set.
Company Profile

Xiamen Xiongba E-commerce Co., Ltd. is a control system component company, located in Siming District, Xiamen, a beautiful coastal city. Xiamen Xiongba E-commerce Co., Ltd. is one of the largest control system components in China, focusing on industrial automation PLC and DCS modules. Our company has 20 years of experience in the field of automatic control. We specialize in supplying world-renowned brands: Allen Bradley, ABB, General Electric, Triconex, Honeywell, Bentley Nevada, Schneider, Hima, and even some...
Contact Us
- Xiamen Xiongba E-commerce Co., LTD
- Contact nameLynn Chat Now
- Phone86-86-18059884797
- AddressRoom 2009, Chuangxiang Center, No. 1733, Luling Road, Siming District, Xiamen xmxblynn@163.com, Xiamen, Fujian
Product Categories
New Products
-
TRICONEX 3825X – TMR System Module for High-Integrity Tricon Safety Control
-
TRICONEX 4355X – TMR System Module for Tricon Safety Instrumented Systems
-
TRICONEX 3617E – High?Integrity Temperature/RTD Input Module for Tricon TMR Safety Systems
-
TRICONEX 3721N – High-Density Analog Input for Safety-Critical Tricon TMR Systems
-
TRICONEX 3601T – System Termination Assembly for Tricon TMR I/O
-
TRICONEX 3601E – Main Processor Module for TMR Safety And High-Availability Control
-
TRICONEX 3502E – TMR Processor Module for Tricon Safety And Critical Control
-
TRICONEX 2770H – TMR System Backplane/chassis Component for Dependable SIS Deployments
-
TRICONEX 8300 – TMR System Chassis/Backplane for Safety-Critical Control
-
TRICONEX 4508 – TMR Module for High-integrity Tricon Safety And Process Control Systems
-
TRICONEX 4610 – Field Termination / I/O Interface for Tricon Safety Systems
-
TRICONEX 3807 Power Module – 220 VAC Supply for Tricon Safety Systems
-
TRICONEX 3674 – Main Processor Module for Tricon TMR Safety Systems
-
TRICONEX 3623 – TMR 24 VDC Discrete Output Module for Safety-Critical Shutdown Control
-
TRICONEX 3511 – TMR I/O Module for Safety-Critical Process Inputs
-
TRICONEX 3201 – Safety I/O Module for Tricon TMR Systems
-
TRICONEX 3005 – TMR Safety System Module for Critical Process Protection
-
TRICONEX 3004 – Compact 4?Slot Chassis for Tricon TMR Safety Systems
-
TRICONEX 2700 – TMR Safety System Hardware for High?Integrity Control
-
TRICONEX 2481 – TMR System Module for High-integrity Safety Control
-
TRICONEX 2301 – Triple-Redundant Module for High-Integrity Tricon SIS Applications
-
TRICONEX EM2291 – Expansion/Interface Module for Tricon TMR Safety Systems
-
TRICONEX 2201 – TMR Safety System Module for High-Integrity Process Protection
-
The PFSA103D 3BSE002492R0001 Motor Controller Offers a High Degree of Reliability
Find Similar Products By Category
- Industrial Equipment & Components > Other Equipment & Components

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Lynn
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile