Home > Products > information acquisition > RS485 Bus Splitter - 2Master-1Slave for PV Systems, Lowers Interface Occupancy
RS485 Bus Splitter - 2Master-1Slave for PV Systems, Lowers Interface Occupancy
- 0 Piece / Pieces per Month
- T/T L/C PayPal D/P Western Union Other
You May Like
-
USB-to-Optical/Near-Infrared Meter Reader Communication Head for Import/Export Smart Electricity Meters with Strong Magnetic Adhesion - IEC
-
MK6E Red Correlation Port Electricity Meter EDMI Protocol Wireless Data Collection Gateway Power Plant Communication Management Machine
-
4G Transmission Non-Invasive Clip-On Current Measurement Sensor for Power Equipment Operation Status Monitoring
-
4G/WiFi Wireless Carbon Dioxide Sensor CO2 Concentration Measurement Transmitter MQTT Cloud Platform API Interface
-
Solar Radiation Measurement and Monitoring, Support Wireless, LoRa Transmission
-
4G Wireless RPM Monitor - Industrial Rotating Machinery Speed Sensor, Hall Element Technology
Product Description
In large-scale photovoltaic power stations, there are usually multiple inverters that generate a large amount of data, such as output voltage, current, power, frequency, and operating status (normal, fault, standby, etc.). This data needs to be accurately and timely collected and transmitted to the monitoring system so that staff can monitor the operating status of the inverters in real-time, detect faults promptly, and perform maintenance to ensure the efficient operation of the photovoltaic power station. Traditional RS485 communication networks mostly operate in a one-master-multiple-slave mode. However, in some complex application scenarios, two master devices need to simultaneously collect data from and control the inverters. For example, in a large-scale distributed photovoltaic power station, there may be both a local monitoring center and a remote monitoring center. The local monitoring center needs to obtain real-time inverter data for on-site operation and maintenance management, while the remote monitoring center needs to aggregate and analyze the operational data of the entire power station for remote dispatching. In such cases, the two-master-one-slave RS485 bus splitter emerges as a solution.
2. Working Principle of the Two-Master-One-Slave RS485 Bus Splitter
The two-master-one-slave RS485 bus splitter connects two master devices and one slave device (such as inverters, meters, anti-islanding devices, power quality monitors, and other photovoltaic power generation auxiliary facilities) to the same RS485 interface, enabling orderly data transmission. It features advanced isolation circuits and collision detection mechanisms internally. When two master devices simultaneously send data requests to the inverter, the collision detection mechanism quickly detects the collision and ensures that data does not conflict based on preset strategies, such as priority settings or time-division multiplexing. Additionally, the isolation circuit effectively isolates electrical interference between different devices, ensuring stable and accurate signal transmission. For example, when Master Device A sends a command to read the real-time power of the inverter, and Master Device B simultaneously sends a command to read the operating status of the inverter, the two-master-one-slave RS485 bus splitter will follow the set rules to first send Master Device A's command to the inverter. After the inverter responds and returns the data, it will then send Master Device B's command, avoiding communication errors caused by data collisions.
3. Implementation Advantages3.1 Multi-Master Collaboration, Flexible and Efficient
Traditional one-master-multiple-slave RS485 networks cannot meet the needs of multiple control centers simultaneously collecting data from and controlling inverters. The two-master-one-slave RS485 bus splitter breaks this limitation, allowing two master devices to flexibly read data and send commands to the inverter based on their respective needs. The local monitoring center can promptly obtain real-time data from the inverter and quickly address on-site issues, while the remote monitoring center can perform macro-level analysis based on the collected data to develop more reasonable operational strategies.
3.2 Signal Enhancement, Extended DistanceRS485 communication has inherent transmission distance limitations. In large photovoltaic power stations, the distance between inverters and the monitoring center may be considerable, leading to signal attenuation and interference during transmission. The two-master-one-slave RS485 bus splitter features signal amplification, enhancing the RS485 signal to effectively extend the communication distance, reduce signal attenuation and error rates, and ensure stable and reliable data transmission to the monitoring center.
3.3 Data Isolation, Stable and ReliableThe internal isolation circuit effectively isolates electrical interference between different devices, enhancing system stability. In the complex electromagnetic environment of a photovoltaic power station, various electrical devices may generate significant electromagnetic interference. The isolation function of the two-master-one-slave RS485 bus splitter can prevent such interference from affecting inverter data acquisition, ensuring data accuracy and integrity.
4. Practical Application CaseA photovoltaic power station adopted the two-master-one-slave RS485 bus splitter for photovoltaic power generation data acquisition. The master device at the local monitoring center is responsible for real-time monitoring of power generation status and data analysis. If any abnormalities are detected, on-site maintenance personnel are immediately notified for resolution. The master device at the cloud-based remote monitoring center periodically analyzes the collected power generation data to optimize the power station's operational strategies. Through the application of the two-master-one-slave RS485 bus splitter, the power station achieved more efficient operational management. The stability and accuracy of data transmission were significantly improved, with fault response times reduced from several hours to within half an hour, and power generation efficiency also saw a notable increase.
Regularly inspect and maintain the two-master-one-slave RS485 bus splitter to promptly identify and resolve potential faults. When communication failures occur, systematically troubleshoot possible causes, such as wiring errors, incorrect baud rate settings, or device malfunctions. Professional testing tools can be used to inspect the devices and ensure their proper operation.
The two-master-one-slave RS485 bus splitter offers significant advantages and broad application prospects in inverter data acquisition. Through proper application and maintenance, it can effectively improve the efficiency and accuracy of inverter data acquisition, providing strong support for the stable operation and efficient management of photovoltaic power stations. With the continuous development of the photovoltaic industry, it is believed that the two-master-one-slave RS485 bus splitter will play an important role in more scenarios, driving technological advancements in the photovoltaic energy sector.
Contact Us
- Shanghai Shucai Internet of Things Technology Co., Ltd.
- Contact namewuxiangyang Chat Now
Product Categories
flow sensor | Wireless data collection | meter reading instrument | information acquisition |
New Products
-
Smart Substation Control Terminal with HV Differential Protection for Solar, Wind, ESS Grid-Tied Applicationsion
-
Wireless AC Current Sensor for Predictive Maintenance and Energy Monitoring
-
Battery-Powered Wireless Data Acquisition Device for Temperature and Load Monitoring
-
Multi-Channel Infrared Communication Transceiver for Data Transmission and Reception
-
"Battery-Powered Wireless Timed Camera for Easy Setup, Remote Viewing, and Motion Detection"
-
Wireless CO2 Sensor for Air Quality Monitoring and Environmental Control
-
Battery-Powered Wireless Ultrasonic Flow Meter with Real-Time Data Monitoring
-
Online Power Quality Detector - Real-Time Monitoring for Electrical Systems
-
Wireless Three-Color Warning Light - High Visibility LED Safety Signal Light
-
Wireless Temperature and Vibration Sensor - Real-Time Monitoring for Industrial Applications
-
Wireless Temperature and Humidity Sensor - Remote Environmental Monitoring Solution
-
MTX100 industrial ethernet switch-MTX100-A5K0005
-
MTX100 industrial ethernet switch-MTX100-A5K0050
-
MTX100 industrial ethernet switch-MTX100-A8K0008
-
“MTX100 industrial ethernet switch-MTX100-A5K0080
-
DAQ-IOT Modbus RTU RS485 Split Core Current Transformer CT AC Analog Signal Coil Sensor DC 12V 5A DC Current Transformer Power On or Off Status Monitoring
-
MK6e Red Gate Electricity Meter EDMI Protocol Wireless Data Acquisition Gateway
-
ModBus-RTU infrared meter reader
-
698 photovoltaic protocol converter photovoltaic inverter power generation electricity consumption information collection
-
Photovoltaic inverter interface converter combined with 698 protocol converter to achieve information collection of inverter power generation and consumption
-
Power IEC104 protocol server client master and slave protocol debugging software tool
-
4G / WiFi/RS485/LoRa/NB Wireless CO2 Sensor
-
4G/RS485/LoRa/WiFi/NB Wireless Irradiance Sensor
-
Wireless Current Acquisition Terminal
Recommended Products
- Wireless Temperature and Humidity Sensor - Remote Environmental Monitoring Solution
- Wireless Temperature and Vibration Sensor - Real-Time Monitoring for Industrial Applications
- Wireless Three-Color Warning Light - High Visibility LED Safety Signal Light
- Online Power Quality Detector - Real-Time Monitoring for Electrical Systems
- Battery-Powered Wireless Ultrasonic Flow Meter with Real-Time Data Monitoring
- Wireless CO2 Sensor for Air Quality Monitoring and Environmental Control
- "Battery-Powered Wireless Timed Camera for Easy Setup, Remote Viewing, and Motion Detection"
- Multi-Channel Infrared Communication Transceiver for Data Transmission and Reception
- Battery-Powered Wireless Data Acquisition Device for Temperature and Load Monitoring
- Wireless AC Current Sensor for Predictive Maintenance and Energy Monitoring
- Smart Substation Control Terminal with HV Differential Protection for Solar, Wind, ESS Grid-Tied Applicationsion
- 4G Wireless RPM Monitor - Industrial Rotating Machinery Speed Sensor, Hall Element Technology
Find Similar Products By Category
- Instruments & Meters > Electronic Instrument > Other Electronic Instruments

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
wuxiangyang
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile