What is steel structure coating?
Fire-retardant coating for steel structure is a coating used in construction projects. Steel structure usually loses its bearing capacity and undergoes great deformation at a temperature of 450-650℃, causing bending of steel columns and steel beams. As a result, it cannot continue to be used due to excessive deformation. Generally, the fire resistance limit of unprotected steel structure is about 15 minutes.
? According to the fire prevention mechanism, steel structure fire retardant coating is divided into:
a) Intumescent steel structure fire retardant coating: The coating expands and foams at high temperature to form a fire-resistant and heat-insulating protective layer of steel structure fire retardant coating. The industry is used to use the old standard name, that is, the intumescent fire retardant coating is a combination of ultra-thin structural fire retardant coating and thin steel structure fire retardant coating.
b) Non-intumescent steel structure fire retardant coating: The coating does not expand and foam at high temperature, and it itself becomes a fire-resistant and heat-insulating protective layer of steel structure fire retardant coating. The industry is used to use the old standard name, that is, non-intumescent fire retardant coating is a thick fire retardant coating.
Steel structure coatings can be tested in accordance with BS 476-21, depending on the product's scope of application as specified in BS 476-21.
?Refer to BS 476-21 Product range:
BS476-21 is mainly used to evaluate the fire resistance of load-bearing building materials under high temperature conditions. It is mainly used to determine the load-bearing capacity, integrity and thermal insulation of beams, floor materials, ceiling materials and walls exposed to high temperature and high pressure conditions within a specified time.
BS 476-21 Standard Name:
BS476-21: Fire test on building materials and structures-Part 21: Method for Determination of the fire resistance of load bearing elements of construction.
The most critical factor in the fire resistance test of steel structure coatings is the thermal insulation performance. You can refer to the standard furnace temperature changes:
According to the standard regulations, the time-temperature is controlled, and the different temperatures at different times are shown as follows:
538°C at 5 min
795°C at 20 min
843°C at 30 min
927°C at 1 h
1010°C at 2 h
1093°C at 4 h
Other times
Contact Us
- CASfire Technical Co.,Ltd
- Contact nameAnne lin Chat Now
- AddressNo.255 South Duiying Road,Jimei, Xiamen, Fujian
Product Categories
railway vehicles | outgassing test | Aircraft Material | Motor Vehicle |
Electrical Products | Plastics Material | Building | CE certification |
Furniture | certification | Electrical | fireproof |
fire test |
New Products
-
ECE R118 Fire Resistance Test: Essential Guide for Vehicle Material Compliance
-
Understanding FMVSS 302: The Fire Safety Standard for Vehicles
-
AS 5637.1 Group 1 fire test of simulated decorative wall panels
-
Analysis of the possibility of FRP meeting BS476-7 Class 1 fire test
-
EN 13501-2 fire resistance test of container composite wall panels
-
ASTM E119 fire resistance test
-
fire test requirements of BS476-7
-
BS 5852 core points
-
test method of BS 5867-2
-
NFPA 260
-
mattress application to BS 7177
-
BS 7176 testing
-
NFPA 701 test
-
EN 45545-2 New Fire test
-
CASfire Fire Test Service
-
TB/T 3237 Chinese Fire test standard
-
American standard ASTM E595-15 Outgassing test
-
NFPA 130 Standard for fixed guideway transit and passenger rail systems
-
DIN 5510-2 Germany Standards to railway vehicles
-
BS 6853 Fire test to railway vehicles
-
NFPA 130 Fire Test to railway component – Reference Standards
-
Airbus Standard:ABD 0031 Fire Test to Aircraft Material PCB
-
FAR 25.853 Fire test to aircraft material
-
Fire Test to railway components - Test method(DIN5510-2)
Popular Searches
Recommended Products
- Expanded polystyrene EU mandatory CE certification
- Foam glass insulation material EN 13167 EU CE certification
- Two minutes to share the waterproof membrane EN 13859 CE certification consultation
- A few minutes of introduction: Wallpaper/wallpaper EN 15102 mandatory CE certification, have you done it?
- Polyurethane steel plate application EN14509 CE certification process
- Let me tell you the difference between ISO 12952-1 and ISO 12952-2 flame retardant tests in one minute
- Discover EN 15102: A Guide to the EU Standard for Adhesive Decorative Materials
- Unlocking EN 12467 CE certification for fiber cement board: opening a passport to the European market
- Share the complete test process of applying for British flame retardant BS6807 for medical mattresses
- Explore BS 476 - 4 Non-combustibility test for building materials
- How to prepare samples for AS1530.1 non-combustibility test of calcium silicate board?
- Benefits of engineered wood flooring: Learn about the EN 14342 System 3 certification process
Find Similar Products By Category
- Service > Other Service

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Anne lin
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile