Brand Name | YT | Place of Origin | China | |
Model Number | JL109 |
Product Description
No Wiring Easy Install Fire Alarm 700 m up to 4000 m Wireless Alarm
Fire Alarm Bell Wire Connection with any brand Conventional 2 wire non-polarized fire alarm control panel. Fire alarm bell will be triggered by smoke detector, heat detector, manual call point for first time fire alarm.
Fire alarm bell or fire sound light alarm device should be installed at every floor of building to alert people of fire.
The bell remains the most commonly used alarm for fire evacuation system, for wall applications, indoors. They are designed to be used in 24 volt DC systems.
Specifications
Voltage ranges: 20vdc to 28vdc (Nonpolarity)
Power and current consumption: 1W, 38ma@24vdc(maximum)
Number of standard: EN54-3
Sound level:80dB(A)@1M (minimum)
Service Use: Fire alarm, general signaling, burglar alarm
Environment type: Type A (indoor)
Input terminal Wire Gauge: 0.28 mm2 to 1.5 mm2
Operating Temp.: -10℃ to +55℃
Operating Humidity Range: 10% to 93% Relative Humidity ( Non-condensing)
Material of cover: Aluminum
Dimension: 150mm×50mm(D*H) (Without bracket)
Weight: Net Weight 342g, Gross Weight 395g
Download fire alarm system instruction and manual at fire alarms
Wiring
The system designer must make sure that the total current drawn by the devices on the loop does not exceed the current capability of the panel supply, and that the last device on the circuit is operated within its rated voltage.
When calculating the voltage available to the last device, it is necessary to consider the voltage drop due to the resistance of the wire. The thicker the wire, the smaller the voltage drops. Wire resistance tables can be obtained from electrical handbooks.
Contact Us
- Vedard Foreign Trade (Quanzhou) Co.,Ltd.
- Contact nameSarah Huang Chat Now
Product Categories
addressable fire alarm system | conventional fire alarm system | wireless fire alarm system | electric fire detection alarm system |
gas leakage monitoring system | Burglar Alarm |
New Products
-
Fire Alarm Repeater Floor Displayer 16 Zones Fire Indicator For Fire Evacuation
-
Wireless Fire Alarm Smoke Detector Fire Detection With Fire Fighting Security Equipment
-
Heat Detector Wireless Fire Alarm And Fire Fighting Security Component
-
Fire Pull Station Fire Manual Call Point Wireless Fire Alarm System
-
Fire Alarm And FIre Fighting Equipment Input Module Fire Fighting Control
-
Wireless Sounder Strobe Wireless Fire Alarm Sound Flashing Lighting Alarm
-
Fire Hydrant Button Wireless Fire Alarm And Fire Fighting Equipment
-
Perimeter Security Infrared Beam Intruder Detector Wireless Alarm Solar Power Photoelectric Beam
-
Small Business Fire Security 2 Zone Alarm Fire Alarm Control Panel
-
4-16 Zones Alarm Conventional Fire Alarm Control Panel Security Controller
-
Fire Alarm And Fire Fighting Gas Extinguish Security Control Fire Controller
-
64 Point Addressable Fire Alarm Control Panel Wireless Fire Alarm System
-
2 Wire 255 Point 1 loop Addressable Fire Alarm Control Panel
-
Gas H2S Alarm Explosion Proof Toxic Gas Detector Environment Security
-
Smoke Detector Fire Alarm For 2 Wire Conventional Fire Security System
-
Fire Alarm Horn Light Sound Alarm Fire Evacuation Business Security Equipment
-
Heat Detector Fire Detection Fire Alarm Fire Prevention Security System
-
Smoke And Heat Detector Compound Fire Detection Fire Alarm Security System
Popular Searches
- Fire Alarm
- fire alarm system
- fire fighting equipment
- Co2 Fire Extinguisher
- pvc hose
- alarm siren
- plastic horn
- Siren Horn
- fire fighting nozzle
- Strobe Siren
- fire extinguisher hose
- strobe lights
- fire extinguisher nozzle
- Fire Alarm Siren
- fire siren
- Horn Strobe
- fire strobe
- alarm system
- security alarm
- fire detector
- Fire Alarm
- door bell
- Electric Door Bell
- Electric Bell
- metal bell
- Strobe Warning Light
- Heat Detector
- fire control
- fire system
- Bell Tent
Recommended Products
- IR3 Flame detector Infrared Flame Sensor Fire alarm
- Tanda Reflective Linear Beam Smoke Detector
- GST Conventional Infrared Reflective Beam Fire Smoke Detector
- CST smoke detector CE certified smoke alarm 2 wires fire sensor for conventional fire alarm system YT102
- Ceiling white 2 wires conventional smoke detector photoelectric smoke sensor fire alarm for fire alarm security system
- Factory Price Explosion-proof Point Type Smoke Fire Detector
- Wireless Sounder Strobe Wireless Fire Alarm Sound Flashing Lighting Alarm
- Fire Alarm And FIre Fighting Equipment Input Module Fire Fighting Control
- Fire Pull Station Fire Manual Call Point Wireless Fire Alarm System
- Heat Detector Wireless Fire Alarm And Fire Fighting Security Component
- Wireless Fire Alarm Smoke Detector Fire Detection With Fire Fighting Security Equipment
- Fire Alarm Repeater Floor Displayer 16 Zones Fire Indicator For Fire Evacuation
Find Similar Products By Category
- Security & Protection > Fire Control > Fire Alarm & Smoke Detector

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Sarah Huang
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile