Modbus RTU/TCP to S7-1200 Protocol Converter
- SHENZHEN
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 15 days
You May Like
Product Details
Brand Name | BLIIOT | Place of Origin | China | |
Model Number | BL122 |
Product Description
BL122 Modbus to PROFINET protocol conversion gateway enables seamless integration of Modbus devices into a PROFINET network. This gateway supports Modbus RTU, Modbus TCP converts data for communication with PROFINET devices. It facilitates real-time data transfer, configuration flexibility, and industrial-grade reliability. Ideal for industrial automation, the gateway enhances system flexibility and scalability, ensuring efficient data exchange and communication across diverse protocols and devices.
Features
? Downlink supports: Modbus RTU, Modbus TCP
? Uplink supports: PROFINET
? 1CH RS232, 2CH RS485
? The network port can be configured via a web interface
? Two Profinet ports support cascading
? Using a PLC to manage and assign IP addresses to network ports enables communication and control between devices.
Technical Parameter
Parameter | Description | |
Power Supply | Input Voltage | DC 12~36V |
Power Consumption | Normal: 192mA@12V, Max: 74mA@36V | |
Ethernet Port | Specification | 3 x RJ45, 3x10/100Mbps |
Protection | ESD: ±6kV(Contact), ±8kV(Air) EFT: 1kV, 5kHz | |
Cascading | Support | |
Serial Port | QTY | 2CH RS485/RS232, 1CH RS232 |
Baud Rate | 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400 | |
Data Bit | 8 | |
Parity Bit | None, Even, Odd | |
Stop Bit | 1, 2 | |
Mode | RTU Master/Slave, TCP Master/Slave | |
Function | 01H, 02H, 03H, 04H, 05H, 06H, 0FH, 10H | |
Connection | Up to 31 connections to a single serial port | |
Protection | ESD ±6kV(Contact), ±8kV(Air) EFT ±1kV, 5kHz | |
Indicator | PWR | Always on when device powered on |
RUN | Flickering when system running | |
LINK | Flickering when TCP communicating | |
485A | Flickering when communicating | |
RS232 | Flickering when communicating | |
Software | Protocol | PROFINET, Modbus |
Max input/output data volume | Input Bytes + Output Bytes ≤496 Bytes | |
Max Input Bytes ≤496Bytes | ||
Max Output Bytes ≤496Bytes | ||
File | GSDML | |
Safety Regulations | EMC | IEC 61000-4-2 (ESD) Level 3 |
IEC 61000-4-4 (EFT) Level 3 | ||
IEC 61000-4-5 (Surge)Level 3 | ||
Others | CE, FCC, RoHs | |
Environment | Working | -30~55℃, 5~95% RH |
Others | Housing Material | Plastic |
Size | 30×83×110mm(LxWxH) | |
Protection | IP30 | |
Mounting | DIN Rail Mounting |
Modbus Master
This device will act as a Modbus master, with serial ports connecting to Modbus slave devices. Using the PLC mapping configuration page, you can configure the host parameters. The device will use Modbus RTU/TCP
protocols to collect data from slave devices and convert Modbus protocol to PROFINET protocol.
l The device supports up to 31 connected devices.
l The number of slave devices being polled should not exceed 31.
l When increasing the number of slave devices, the baud rate should also be increased accordingly, and the interfaces can be used simultaneously.
l The range for slave IDs is 1 to 241.
Users can connect various slave devices via RS485 serial port, RS232 serial port, or Ethernet port to expand I/O capabilities and read/write data from smart meters and devices. For example, connecting to BLIIOT Mxxx series remote I/O modules enables expansion of digital input (DIN), digital output (DO), analog input (AI), analog output (AO), and PT100 input quantities. Alternatively, connecting to power parameter monitoring modules allows reading of three-phase electrical parameters such as current, voltage, and power. Additionally, connecting to UPS (Uninterruptible Power Supply) units enables parameter monitoring.
Combining these smart devices in different configurations meets the functional requirements of most application scenarios.
Modbus Slave
This device can act as a Modbus slave, with serial ports connecting to Modbus master devices. Using the PLC mapping configuration page, you can configure the host parameters. The master device can then collect data from this device using Modbus RTU protocol (RS485 and RS232 interfaces) or Modbus TCP protocol (Ethernet interface). Each slave device configuration cannot overlap; only one command with multiple function codes can be assigned per slave.
Modbus to PROFINET
This device will convert Modbus RTU or Modbus TCP protocols into PROFINET protocols, acting as either a Modbus master or slave communicating with PROFINET devices.
2 Supports simultaneous use of RS485, RS232, and TCP interfaces.
2 Supports data acquisition of 496 bytes per individual serial port, with all serial ports collectively capable of acquiring 496 bytes of data.
2 Supports TCP/RTU data acquisition from up to 31 slave stations (number of stations depends on the baud rate).
2 Supports Modbus RTU and Modbus TCP as both master and slave, with the ability for transparent data transfer (passthrough) between devices.
2 Supports simultaneous use of multiple function codes.
2 Support Modbus RTU protocol, support 01H, 02H, 03H, 04H, 05H, 06H, 0FH, 10H function codes
2 Support baud rate 2400, 4800, 9600, 19200, 38400, 57600, 115200, 230400
Web Page Configuration
The device supports web configuration using a wired connection. To configure the device, connect your computer to the configuration port using an Ethernet cable. Open a web browser on your computer and enter the default login address for the device, which is 192.168.3.10. The default login username is "admin" with no password required.
This address can be modified either through a web interface or through PLC programming.
Wired connection
On the PC side, there are two methods to configure its IP address:
1, Enable automatic IP address assignment on the PC's local connection, allowing the PC to obtain an IP address automatically from the router.
2, Manually configure a static IP address on the PC's local connection within the same subnet as the router.
Below is an example using Windows 7 for configuration. Configuration steps for Windows systems are generally similar.
1, Click on "Start > Control Panel > Network and Sharing Center." Then, in the window that opens, double-click on "Local Area Connection."
Contact Us
- Shenzhen Beilai Technology Co., Ltd.
- Contact nameEcho Wu Chat Now
Product Categories
New Products
-
Modbus to Ethernet/IP Protocol Converter
-
Modbus RTU to Ethernet/IP Protocol Converter
-
Support Modbus MQTT Industrial Router with DI DO AI RS485 Remote Data Acquisition Control
-
RS485 Serial Port Modbus RTU Router with Logic Control AI DI DO for Smart City
-
Remote Data Acquisition Control 4G Industrial Router with 4AI RS485 for Smart Water Conservancy
-
MQTT Protocol Wireless Data Acquisition Gateway Supports SSL Encryption with AI DI DO RS485
-
Support wireless Network Access RS485/DI/DO/AI 4G Edge Router for Smart City
-
Wireless Industrial Edge Router Supports Logic Control OEM ODM with DI DO AI RS485
-
Remote Data Acquisition Router R40B with AI DI DO RS485 for Smart Water Conservancy
-
Industrial IoT Gateway with 4AI 2DO 1RS485 Logic Control for Smart Transportation
-
MQTT Protocol Wireless Gateway Data Collection Access Cloud Platform Supports SSL Encryption
-
RK3568J/RK3568B2 4*A55 64-Bit ARM Controller with GPIO CAN for AIoT to Optimize Urban Resources
-
ARMxy Series RK3568J 4*A55 Embedded Computer with 1TOPS NPU Supporting Machine Learning
-
ARMxy ARM Embedded Computer Supports 1TOPS NPU for Machine Learning
-
Embedded Computer ARMxy Series RK3568J 4*A55 Support Node-Red PWM with CAN GPIO for AIoT
-
ARMxy Series Industrial Computer RK3568J 4*A55 64-Bit Supports Python for Machine Learning
-
ARM Industrial Edge Computing Gateway Equipped with Ubuntu OS Supports Secondary Development
-
Embedded ARM Controller RK3568J/RK3568B2 4*A55 22nm Process for Artificial Intelligence
-
ARMxy ARM Industrial Computers Support Linux OS for AIOT
-
ARMxy Series Edge Computing Gateway RK3568J 4*A55 64-bit with GPIO CAN Support Node-Red
-
ARMxy ARM Controller T507-H 4*A53 Equipped with Linux OS for Cloud-Edge Smart Terminals
-
ARMxy Embedded Computer T507-H 4*A53 64-Bit Supports Python for Machine Learning
-
ARMxy Artificial Intelligence Embedded System Supports Ubuntu OS Secondary Development
-
ARMxy Embedded Intelligent Terminal Supports Python for AIoT
Popular Searches
- pcb assembly
- ip phone
- gsm gateway
- voip gateway
- voip
- goip
- wireless router
- voip phone
- sip phone
- sip
- gsm fixed wireless terminal
- ip gateway
- Wireless Temperature Sensor
- ata
- voip ata
- voip adapter
- power supply module
- fxs
- smart home gateway
- intelligent gateway
- Lighting Gateway
- signal repeater
- power module
- transceiver
- optical multiplexer
- media converter
- gateway
- ethernet bridge
- multiplexer
- network bridge
Recommended Products
- QUECTEL SC60EYE-32GB-UGAD
- Wi-Fi and Bluetooth Gateway Beacon positioning base station iBeacon signal reception data collector
- DR9074-Triband QCN9024 4x4 MU-MIMO wifi6E 11ax 2.4G&5G&6G
- WiFi6 routerboard IPQ5018 SOC 2.4G&5G&6G on board openwifi
- Ultra-small size, Cost-Effective Bluetooth module TS-M1021
- Cost-Effective, low power consumption Bluetooth module TS-M1029D
- Cost-Effective, Ultra-small size Bluetooth low power Dual mode Bluetooth module TS-M1020D
- Cost-Effective High Quality dual-mode Bluetooth module TS-M1031D
- Cost-Effective High Quality BLE Bluetooth module TS-M1032D
- Cost-Effective, High Quality High Speed master-slave supported BLE Bluetooth module TS-M1033
- Cost-Effective, High Quality High-Speed master-slave supported Bluetooth Module TS-M1035
- Cost-Effective, High Quality High-Speed master-slave integrated BLE 5.2 Bluetooth module TS-M1036
Find Similar Products By Category
- Electrical & Electronics > Telecommunication & Broadcasting > WiFi Products

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Echo Wu
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile