- Zhuhai City Snova Technology Co., LTD
-
Zhuhai, Guangdong, China
- Main products: Earth Fault Indicator, Cable Fault Indicator, Overhead Line Ground Fault Indicator, Short Circuit and Earth Fault Indicator, Cable Temperature and Faults Sensor, Industrial Dehumidifier, Temperature and Humidity Controller, Fault Passage Indicator, Remote communication terminal, Smart grid system
Home > Products > Short Circuit and Earth Fault Indicator > SNV-EKL3.2 Earth fault and short circuit indicator
SNV-EKL3.2 Earth fault and short circuit indicator
- 10000 Piece / Pieces per Month
- shenzhen
- T/T
- 15 days
You May Like
-
SNV-EKL4 V2.1 Earth Fault Indicator for MV Power Distribution Network
-
SNV-EFI Earth Fault Indicator
-
Control PDA for Fault Locator In Transmission Lines
-
Grounding Faul Indicator earth fault indicator
-
Electric Handcart and Ground Knife Integrated Protector
-
fault locator of Power distribution equipment
Product Details
Brand Name | SNOVA | Place of Origin | China | |
Model Number | SNV-EKL3.2 |
Product Description
SNV-EKL3.2 Earth fault and short circuit indicator
Description
SNV-EKL3.2 Earth fault and short circuit indicator, it Widely used in various ring cabinets, high-voltage switch-gear and cable branch box in power system, can accurately and reliably detect the fault section and fault type of power grid. The use of Earth fault and short circuit indicator is an efficient way to check cable fault, and is an effective way to improve the operation level of distribution network and the efficiency of fault handling. The design uses electromagnetic induction, photoelectric conversion, signal optical fiber transmission and single chip microcomputer control technology to make fault alarm with high accuracy and strong anti-interference ability.
Equipped with fault remote transmission port, suitable for distribution network automation; Battery low power alarm indication; Low-power design, high-capacity lithium battery power supply, long battery life (more than 8 years); external structure using card or lock design, the whole machine is easy to load and unload.
Function character
1) Intelligent detection of short-circuit and ground fault and through the corresponding LED indicator on the panel to indicate.
2)Display Monitor panel designed with button, it is convenient for reset/or test.
3)It can set The pulse width time(Response time) of fault current for preventing incorrect fault indication caused by surge current.
4)It can set the reset time.
5)It can set the short circuit alarm current via the Dip on short circuit sensor
6)It can set the earth fault alarm current via the Dip on display unit monitor.
7)It can reset and detect the remote fault indication device remotely.
8)It can provide switch volume for external devices through remote relay contact.;
9)Remote fault indicating can be made by external devices.;
10)Low battery display and alarm
Function description
1) short circuit alarm indicating: when short circuit sensor detected a short circuit fault current, when the current is greater than or equal to the setting value, then the short circuit sensor send alarm signal to monitor panel through fiber. And the monitor will display the alarm signal, the short circuit fault LED will be flash.
2) Earth fault alarm indicating: when the earth fault sensor detected a earth fault current, when the current is greater than or equal to the setting value, then the earth fault sensor send alarm signal to monitor panel through cable. And the monitor will display the alarm signal, at same time, the earth fault LED will be flash.
3) Battery low voltage alarm indicating: the monitor use the battery to supply power. When the battery voltage is lower than the min. working voltage 2.7V, then the Low voltage alarm led will flash.
4)Automatic reset: After the indicator alarm the fault, if there are without manual reset it, when the time reach our Reset time setting, indicator will automatically reset.
5) Manual Reset: After the indicator alarm the fault, user can press the button “ reset/test” to reset it.
6)Remote Reset: During indicator indicating fault, Through the pin 11-12 back of the monitor, connect the remote button to control the indicator reset.
7)Remote Test: During indicator on normal condition, Through the pin 11-12 of the monitor, connect the remote button to operate simulation test.
8) Remote indicating fault: Connect an External Lamp on the pin 9-10, when the indicator indicating fault, the External blink at same time, then achieved long distance indicating fault.
9) Remote upload SCADA: connecting connect pin13-14, or Pin13-15, when indicator indicating fault, A signal will be upload to SCADA.
Technology parameter
Voltage grade | 3-40.5KV | Battery life | ≥8year | ||||
Frequency | 50HZ/60HZ | Low voltage alarm of battery | ≤2.7V | ||||
Short circuit alarm current (7 levels) | 200/250/300/400/500/600/1000A | Short circuit sensor fiber length | 4meter, or customized | ||||
Earth fault alarm current (6 levels) | 10/20/30/40/50/60A ,or customized | Earth fault sensor cable length | 5 meter,or customized | ||||
Reset time (4 levels) | 4H/8H/24/36H | Load fluctuation and escape pulse time setting | Short circuit | 40/60/80/160ms (4 levels) | |||
Rated frequency withstand voltage | 2KV/1min | Earth fault | |||||
Relay contact capacity | ≤95W | work environment | Temperature | -40℃~+60℃ | |||
Alarm current accuracy | ±10% | Humidity | ≤95%RH | ||||
Working power | ER17505 battery | 3.6V/3500mAh | Use for cable diameter | Short circuit CT (Fiber, Type S) | A | Ф20mm~40mm, Normally | |
B | Ф300mm~70mm customized | ||||||
Working current | Standby state | ≤10μA | Earth fault sensor (Cable, type E) | A | Ф60mm~100mm Normally | ||
Working state | ≤1mA | ||||||
Indicator protection level | Monitor panel | IP 40 | B | Ф80mm~130mm Customized | |||
Sensor CT | IP 67 |
Contact Us
- Zhuhai City Snova Technology Co., LTD
- Contact nameAndrewmao Chat Now
- Phone86-13570657698-8621065
- AddressXiangzhou district, Zhuhai, Guangdong
Product Categories
New Products
-
SNV-EKL4 V2.1 Earth Fault Indicator cable sensor
-
Grounding Fault Sensor and Current Short Circuit Indicator
-
12 Meters Hotstick Installation adapter of Overhead Line Fault Indicator
-
12 Meters Hotstick Installation adapter of Overhead Line Fault Indicator
-
SNV-EKL4 V2.1 short circuit fault sensor for distribution network
-
Industrial intelligent dehumidifier for distribution cabinet
-
Simulated Failure Remote Controller for Overhead Line Fault Indicator
-
Medium-voltage Distribution System Short-circuit and Ground Fault Device
-
How to install Cable type earth fault and short circuit indicator EKL4
-
How to install Cable type earth fault and short circuit indicator EKL4
-
Cable short circuit and grounding fault indicator SNV-EKL3.2
-
what is Overhead line short circuit and grounding fault sensor ?SNV308 FPI
-
Vertical Break Isolating Switch Comprehensive Protection Device
-
Medium-voltage Distribution System Short-circuit and Ground Fault Device
-
Medium-voltage Distribution System Short-circuit and Ground Fault Device
-
New type digital Intelligent overhead line type cable short circuit and ground fault indicator for power distribution line SFI
-
New type digital Intelligent overhead line type cable short circuit and ground fault indicator for power distribution line SFI
-
Fault Indicator Remote Wireless Communication Terminal
-
Fault Indicator Remote Wireless Communication Terminal
-
China factory supplier Power Accessories
-
current and temperature online inspection fault sensor
-
On-line current temperature short circuit fault detector
-
SNV-EKL3.2 Short circuit and earth fault indicator with multigear
-
Fault Indicator Remote Wireless Communication Terminal
Popular Searches
- ring main unit switchgear
- earth fault indicator
- short circuit fault indicator
- spare parts
- auto parts
- alarm system
- auto accessory
- pressure sensor
- air flow meter
- pressure transducer
- pressure transmitter
- auto sensor
- temperature controller
- temperature sensor
- pressure gauge
- Sensor Switch
- permanent magnet
- neodymium magnet
- Neodymium Ndfeb Magnet
- load cell
- proximity switch
- Current Sensor
- square magnet
- alnico magnet
- Neodymium Iron Boron Magnet
- industrial magnet
- sensor magnet
Recommended Products
- overhead line fittings-eye bolt/ pig tail hook
- Adjustable Bow/Tubular Stay rod
- ABB DSDI131 57160001-GV DIGITAL INPUT MODULE
- ABB DSDI131 57160001-GV DIGITAL INPUT MODULE
- ABB DSDI131 57160001-GV DIGITAL INPUT MODULE
- ABB DSDI131 57160001-GV DIGITAL INPUT MODULE
- ABB DSTD 110A 57160001-TZ Connection Unit new
- ABB DSTC170 57520001-BK communication interface unit
- ABB DSSR170 48990001-PC power supply unit
- ABB DSQC652 3HAC025917-001 I/O Unit brand new
- ABB DSQC643 3HACO24488-001 Panel Board New
- ABB DSQC611 3HAC13389-2 Contactor Unit new
Find Similar Products By Category
- Electrical & Electronics > Power Supply & Distribution > Electric Power Fitting

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Andrewmao
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile