
- Acrel Electric Co., Ltd
-
Shanghai, China
- Main products: Hall Sensor, Split Core Current Transformer, AC Energy Meter, DC Energy Meter, IoT Wireless Power Meter, PV/Solar Inverter Energy Meter, Data Center Power Meter, Wireless Temperature Monitoring System and Sensors, Medical IT Products, City Utility Tunnel Moter Protector, Electrical Insulation Safety Products, Energy Quality Improvement
Home > Products > AGF Series Solar String Monitoring Device > AGF-M16T DC Multi-Circuits Monitoring Device for PV Combiner Box Solar Monitoring 3 Phase Power Meter Split Phase Smart Meter
AGF-M16T DC Multi-Circuits Monitoring Device for PV Combiner Box Solar Monitoring 3 Phase Power Meter Split Phase Smart Meter
- 1 Kilogram / Kilograms per Month
- T/T L/C Credit Card PayPal
You May Like
-
AGF-M16T DC Multi Circuit Current of Up 24 Circuits 35mm DIN Rail Main Body Power Supply 1000V DC 1500V DC For PV Combiner Box
-
Acrel AM5SE-F motor protector with RS485 fault recorder application line/feeder 4-20mA analog output
-
Acrel motor protection relay AM5SE-D2 application transformer(2000kVA) 4-20mA analog output remote control GPS FC block
-
Acrel AM5SE-TB motor comprehensive protection device application transformer 4-20mA analog output remote control GPS FC block
-
Acrel application PT supervision and paral AM5SE-UB Motor controller trip and close circuit supervision motor start overcurrent
-
Acrel start control motor protector AM5SE-MD application high power asynchronou 4-20mA analog output remote control GPS FC block
Product Details
Brand Name | Acrel | Place of Origin | China | |
Model Number | AGF-M16T-P2 | Size | Miniature | |
Usage | General Purpose | Contact Load | Low Power | |
Protect Feature | Sealed | Theory | Voltage Relay |
Product Description
General
AGF-T Perforation type PV confluence acquisition device is specially designed for smart PV combiner box. It is used for monitoring the running state of solar panels in solar cell arrays, measuring the currents of solar cell, detecting the state of surge protection devices and DC breaker. The device is equipped with RS485(Modbus) communication port for transmitting all the datas to master device.
Coding Rule
Characteristics
◆ Primary current is connected in through perforation. Easy installation, high safety.
◆ With Hall sensor, the max isolation measuring current 20A
◆ Voltage measurement range for Bus bar is up to DC1.5kV
◆ LED display, fit for checking and testing operation in wide-temperature or outside environment.
◆ With the function of inner temperature measurement for real-time measurement of the inner
temperature of combiner box
◆ With RS485 Modbus RTU
◆ More options of power supply
◆ Compatible with din rail installation and baseboard fixation installation, small dimension saving more
box space.
Main Function
◆ Photovoltaic cell open circuit alarm to cooperate with group string voltage and judge Comprehensively
◆ With 3-channel switching state monitoring to collect output idle contact information of DC breaker 、lightning protector. protector etc
◆ Option RS485 port, Modbus-RTU protocol; programmable slave address, baud rate, data format
◆ English LCD display,convenient to set parameters and check the data
Technical Parameters
Dimension drawings (Unit: mm)
Power supply module size(Figure 1)
Note: Imaginary line is the fixing size of the bottom plate
As power supply module is heavy, bottom plate is needed in installation to avoid its coming off during
transportation.
Confluence acquisition module installation dimension
8-channel confluence acquisition module installation dimension(Figure 2)
4-channel confluence acquisition module installation dimension(Figure 3)
Configuration of 8-channel or 4-channel confluence acquisition module will be decided by actual needs:
when 4 channels or less are needed, 4-channel confluence acquisition module will be installed, when
needed channel number is 5 to 8, 8-channel confluence acquisition module will be installed. When needed
channel number is more than 8, then the number will be divided by 8. If there is a remainder in the result
and the remainder is less than 4, then 4-channel confluence acquisition module will be installed. If the
remainder is more than 4, 8-channel confluence acquisition module will be installed.
LCD display module installation dimension (Figure 5)
Connections of modules
Data cable connection way
The connection between each module is through the external data line. Please confirm the
sequence of the two external data line ports before connecting each module. Each confluence
acquisition module has two outside connection ports(Figure 4): Port I and Port II, in which Port I is used
to connect upstream module and Port II is used to connect follow-up modules. Please pay attention to it
that the propulsion part of the data line connector must be fixed with the groove on the port.
The connection sequence order of PV confluence acquisition modules must follow: confluence
acquisition module 1’s port Ⅱ-->confluence acquisition module 2’s port Ⅰ ,
confluence acquisition module 2’s port Ⅱ-->confluence acquisition module 3’s port Ⅰ .
When connecting the confluence acquisition modules ,multiple confluence modules should be in
sequence order, it is not allowed to insert any other function module between two sequenced confluence
modules. Wrong connection will lead to abnormal operation of the device.
LCD display module can be connected with Port II of confluence acquisition module, The LCD
display module is not necessary to be connected in at ordinary time except when testing and checking.
The address allocation of PV confluence acquisition module is automatically distributed by the
power module(main module), The first confluence acquisition module connected to the power module
will be distributed automatically with 1st to 8th channels, and the next confluence acquisition module
connected to port II will be distributed automatically with 9th to 16th channels, the final confluence
acquisition module is distributed automatically with 17th to 24th channel.
Installation schematic
Note: The arrow shows current direction. Wrong connection will lead to abnormal operation of the device.
Definition of input port
After the address of confluence acquisition module is distributed by the main module,the input
channel address of first module is from 1st to 8th channel,the input channel address of second
confluence acquisition module is from 9th to 16th channel,the input channel address of final confluence
acquisition module is from 17th to 24th channel. The input channel definition of 1st to 8th channel of a
single module is shown as Figure 3.
Contact Us
- Acrel Electric Co., Ltd
- Contact nameShelly Zhang Chat Now
- Phone86-21-18702111813
Product Categories
New Products
-
Acrel RS485 motor protector AM5SE-D3 application main power transformer protection three winding main power transformer r
-
Acrel motor protection relay AM5SE-K application public measurement and control device remote measurement
-
Acrel WHD20R-11/C with RS485 communication 35mm DIN Mount Intelligent temperature and humidity controller High precision
-
Acrel WHD20R-22/J with alarm Intelligent temperature and humidity controller measure two channel temperature&humidity 35mm DIN Mount
-
Acrel WHD46-22/C with RS485 communication Intelligent temperature and humidity controller Used in high and medium voltage switch cabinet, ring network cabinet, terminal box, etc
-
Acrel WHD72-22/M with two analog output measure two channel temperature&humidity with sensors Intelligent temperature and humidity controller
-
Acrel WHD20R-11/J with alarm 35mm DIN Mount Intelligent temperature and humidity controller High precision
-
Acrel WHD48-11/C with RS485communication digital temperature and humidity controller High precision and wide measuring range
-
Acrel WHD72-22/J with alarm measure two channel temperature&humidity with sensors Intelligent temperature and humidity controller
-
Acrel WHD72-22/C with RS485 communication measure two channel temperature&humidity with sensors Intelligent temperature and humidity controller
-
Acrel analog signal isolator BM-AI/IS input AC0-1/5A output DC4-20mA powered by output
-
Acrel current isolator BM-DIS/I input DC4-20mA output 4-20mA powered by input
-
Acrel input DC0-5/0-10V output 4-20mA power DC24V current isolator BM-DV/I
-
Acrel input PT100 output 4-20mA powered by output analog signal isolator BM-AI/IS
-
Acrel DC Multi-function Energy Meter PZ72-DE Accuracy 0.5% Power Supply 85~265V AC/DC Communication RS485
-
Multi Function 1-circuit DC kWh Rated Voltage 1000V DC Rated Current 10A DC 4 Tariff Rates LCD Display kwh Meter Digital
-
PZ72L-DE Paired With Hall Sensor 10A DC Direct Connect PZ Series DC Power Analyzer Rated Voltage 1000V DCW
-
Multi-function Power Meter PZ72L-DE Direct Current 4 Tariff Rates Power Supply 85~265V AC/DC PZ Series DC Power Analyzer
-
Power Monitoring Controlling Power Monitoring Controlling 4 Tariff Rates CE Certificates Rated Voltage 1000V DC PZ72-DE
-
Acrel input DC4-20mA output 4-20mA powered by DC24V analog signal isolator BM-DI/I
-
Acrel analog signal isolator BM-DI/V input DC0-20/4-20mA output 0-5/0-10V power 24V
-
Acrel current isolator BM-DI/IS input DC 0-1/0-20/4-20mA output 4-20mA powered by output
-
ADW310-D16/4GHW IoT One Phase Wireless Smart Energy Meter 20(100)A AC via paired CT iot Smart Meter For House
-
ADW310-D16/4GHW IoT One Phase Wireless Smart Power Meter 220~264V Wireless 4G-LTE Communication IOT 20(100)A AC
Popular Searches
- voltmeter
- panel meter
- multimeter
- ammeter
- measuring instruments
- electronic meter
- Energy Meter
- Phase Multifunction Meter
- Power Meter
- Energy Power Meter
- kwh meter
- electric meter
- Electricity Meter Box
- Digital Energy Meter
- watt-hour meter
- electric meter remote wireless
- digital meter counter
- electricity meter case
- smart ammeter
- smart metering
- Electricity Meter Lcd
Recommended Products
- 41A325938G2 GE CARD KOMATSU 830E 930E MT4400AC MT3600 MT3700 NHL NTE240 NTE260
- GE1483 CARD KOMATSU 830E 930E 730E MT4400AC MT3600 MT3700 NHL NTE240 NTE260 NTE160
- Phoenix Contact Safety relay PSR-SCP-24DC/ESP4/2X1/1X2 2981020
- One New SCHNEIDER LADT2 0.1-30s Time Delay Block
- Schneider RM22TG20 3 Phase Control Relay RM22-TG
- Omron G3PE-225B 12-24VDc Solid state relay
- New original YOKOGAWA Yokogawa PLC F3LX02-0N
- 1734-TOPS Module Rockwell Allen-Bradley new stock 1734TOPS
- 1734-EPAC Power module Rockwell Allen-Bradley Brand new spot 1734EPAC
- 855P-B30ME22 Buzzer Rockwell Allen-Bradley New stock 855PB30ME22
- 2094-EN02D-M01-S0 Control module Rockwell AB new spot 2094EN02DM01S0
- 1734-AENTR Bargaining AB Rockwell PLC module Allen-Bradley; POINTI/O1734
Find Similar Products By Category
- Electrical & Electronics > Relay & Contactor > Relay
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
Shelly Zhang
Welcome to my shop, I'm glad to serve you. Please feel free to send me any questions you may have.
Your message has exceeded the limit.
- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile