Module spare parts IS200DTAIH1ABB
- xiamen
- T/T L/C D/P D/A Credit Card PayPal Cash Escrow Other
- 1 days
You May Like
Product Details
Brand Name | GE | Model Number | IS200DTAIH1ABB |
Product Description
Focus on DCS, PLC, robot control system and large servo system.
Main products: various modules / cards, controllers, touch screens, servo drivers.
Advantages: supply of imported original products, professional production parts,
Fast delivery, accurate delivery time,
The main brands include ABB Bailey, Ge / fuanc, Foxboro, Invensys Triconex, Bently, A-B Rockwell, Emerson, ovation, Motorola, xyvom, Honeywell, Rexroth, KUKA, Ni, Deif, Yokogawa, Woodward, Ryan, Schneider, Yaskawa, Moog, prosoft and other brands
IS200DTAIH1ABB |
0 The value of first supervised parameter is below supervision limit 11 1 External control location 2 (EXT2) selected 0 External control location 1 (EXT1) selected 12 1 Run Enable signal received 0 No Run Enable signal received 13 to 15 Unused 27 COMMUNICATION Actual Values Actual values are read-only values containing information on the operation of the drive. Actual values are 16-bit words containing sign bit and a 15-bit integer. A negative value is given as two’s complement of the corresponding positive value. Actual Value 1 Holding Register: 40005 Actual output frequency. Scaling: 5000 50 Hz. Actual Value 2 Holding Register: 40006 Actual output current. Scaling: 10 1 A. 28 Figure 12 The state machine for evaluation of start and stop signals. MAINS OFF Power ON (CW Bit0=0) (SW Bit6=1) (SW Bit0=0) From any state f=0 / I=0 OFF1 (CW Bit0=0) OFF1 ACTIVE (SW Bit1=0) A CD (CW Bit3=0) (SW Bit2=0) (SW Bit0=1) (CW=xxxx xxxx xxxx x110) (CW=xxxx xxxx xxxx x111) (SW Bit1=1) (CW Bit5=0) (CW Bit3=1 and f=0 / I=0 (SW Bit2=1) From any state SWITCH-ON INHIBITED NOT READY TO SWITCH ON OPERATION INHIBITED READY TO SWITCH ON READY TO OPERATE OPERATION ENABLED C D From any state Emergency Off OFF2 (CW Bit1=0) OFF2 (SW Bit4=0) ACTIVE From any state Fault FAULT (SW Bit3=1) (CW Bit7=1)* *This state transition occurs also if the fault is reset from any other source (e.g. digital input). (SW Bit5=0) Emergency Stop OFF3 (CW Bit2=0) SW Bit12=1) RFG: ACCELERATOR ENABLED (CW Bit5=1) (CW Bit6=0) C (CW Bit6=1) (SW Bit8=1) D A D OPERATING OFF3 ACTIVE State I = Output current CW = Control Word f = Output frequency SW = Status Word RFG = Ramp Function Generator 29 COMMUNICATION Fault and Alarm Status The ACS140 provides fault and alarm status words that are accessible only from the serial communication link (not from the control panel). These status words are located in place of parameter group 3 (Modbus holding registers 40301- 40309). These registers also contain copies of the Command Word (40001) and Status Word (40004). Registers 40301-40309 are generally read-only type; however, alarm words can be reset by writing zeros into the register. Table 10 lists the fault and alarm words. Table 10 Fault and alarm status words. No Name Description 40301 MAIN COMMAND WORD Read-only copy of the Command Word (40001). See page 24. 40302 MAIN STATUS WORD Read-only copy of the Status Word (40004). See page 26. 40305 FAULT WORD 1 Fault information. When a fault is active corresponding bit is set. Bit descriptions are given in Table 11. 40306 FAULT WORD 2 Fault information. Bits 0 - 7 of this register may be set if there is a hardware error in ACS 140 (fault codes 18 - 22). 40308 ALARM WORD 1 Alarm information. When an alarm is active corresponding bit is set. Bits remain set until whole alarm word is reset by writing 0 to it. See Table 12. 30 Table 11 FAULT WORD 1 bit descriptions. Table 12 ALARM WORD 1 bit descriptions. Bit # Description 0 Overcurrent 1 DC overvoltage 2 ACS140 overtemperature 3 Fault current 4 Output overload 5 DC undervoltage 6 Analogue input 1 fault 7 Analogue input 2 fault 8 Motor overtemperature 9 Panel loss 10 Parameters inconsistent 11 DC bus ripple too large 12 Motor stall 13 Serial communication loss 14 External fault 15 Output earth fault Bit # Description 0 Overcurrent controller alarm 1 Overvoltage controller alarm 2 Undervoltage controller alarm 3 Direction lock alarm 4 Serial communication loss 5 Modbus exception generated locally 6 Analogue input 1 loss 7 Analogue input 2 loss 8 Panel loss 9 ACS 140 overtemperature 10 Motor overtemperature 11 Motor stall alarm
Contact Us
- Xiamen xiongba e-commerce Co., Ltd
Product Categories
ABB | EPRO | PROSOFT | NI |
REXROTH | Schneider | Miscellaneous brand | EMERSON |
SEW | SIEMENS | GE | SST |
A-B | TRICONEX | WATLOW | WOODWARD |
YAMATAKE | YOKOGAWA | HONEYWEL | BENTLY |
FOXBORO | FSC | ENTERASYS | HIMA |
TRIPLEX |
New Products
-
Module spare parts IS200STCIH6AED
-
Module spare parts IS200TBCIH1CCD
-
Module spare parts IS200TBCIS2CCD
-
Module spare parts IS200TDBTH6ACD
-
Module spare parts IS200TPROS1CBB IS230TSPRH1C
-
Module spare parts IS200TPROS1CBB IS230TSPRH1C MRP680538
-
Module spare parts IS200TREAH2AED
-
Module spare parts REXROTH KE 310 Typ 0680830240 KE310
-
Module spare parts PPC322BE HIEE300900R1
-
Module spare partsPPC380AE01 HIEE300885R1
-
Module spare parts PPC380AE102
-
Module spare parts PPC380AE102 HIEE300885R0102
Popular Searches
Recommended Products
- Bently Nevada 33130-085-03-00
- Bently Nevada 330730-080-00-00
- Bently Nevada 330500-04-04
- Bently Nevada 330780-51-05
- Bently Nevada 21000-28-05-00-041-03-02
- Bently Nevada 190501-07-00-04
- Honeywell 2MLR-CPUH/T
- Honeywell 2MLR-CPUH/S
- Honeywell 2MLR-CPUH/F
- Bently Nevada 990-05-70-01-00
- Bently Nevada 990-05-50-01-00
- Bently Nevada 990-05-70-03-05
Find Similar Products By Category
- Electrical & Electronics > Power Transmission & Transformer > Transformer

Product Tags:
- Please Enter your Email Address
- Please enter the content for your inquiry.
We will find the most reliable suppliers for you according to your description.
Send Now-
sales
Hi there! Welcome to my shop. Let me know if you have any questions.
Your message has exceeded the limit.

- Contact supplier for lowest price
- Customized Request
- Request Sample
- Request Free Catalogs
Your message has exceeded the limit.
-
Purchase Quantity
-
*Sourcing Details
Your inquiry content must be between 10 to 5000 characters.
-
*Email
Please enter Your valid email address.
-
Mobile